9
8
FITTING THE OPTIONAL BACKGUARD
Island trim and backguard
●
It is mandatory to install and use the appliance with either
the island trim or the optional backguard correctly in place.
●
The island trim is already fitted to the appliance while the
backguard can be purchased as a separate kit.
●
If replacing the island trim with the backguard, assemble it
by using
the same screws/spacers used for fixing the island trim.
9
LOCATION OF ELECTRICAL & GAS SUPPLY
Final position of cooker against wall
Left side
of cavity
Floor
Gas
Electricity
E
B
A
D
c
A
SUPPLY AREA DIMENSIONS
inches (mm)
A
Distance from either edge of
Range to supply area
1/4” (6)
B
Height of supply area (from floor)
8 1/8” - 10 1/8” (207-257) *
C
Width of gas supply area
23 9/16” (599)
D
Width of electrical supply area
11 13/16” (300)
E
Depth of supply area (ie
maximum protrusion of gas and
electrical connection from wall)
4 1/2” (115)
*
Depending on adjustment of feet
Grounded outlet (Gas Gas)
●
The electric cord with 3-prong ground plug
(NEMA 5-15P) has a length of 72” (1830mm).
Grounded outlet (Dual Fuel)
●
The electric cord with 4-prong ground plug
(NEMA 14-50P) shall have a minimum length
of 48” (1220mm) beyond the back of the