517792A
38
112. (01110000) Motor Current Sense Too High
This fault occurs if the Motor Control Module detects that the motor current has reached an
unrealistically high level for greater than 2 seconds. This suggests that the motor current
sense circuit is faulty.
Primary source:
Motor Control Module.
Action:
Replace Motor Control Module.
113. (01110001) AC Pump Thermistor Short Circuit
The AC Pump thermistor has been detected as being short circuit. This means that the
Motor Control Module can no longer monitor AC pump Triac temperatures correctly.
Primary source:
Motor Control Module.
Action:
Replace Motor Control Module.
130. (10000010) Single Rotor Position Sensor Error
The Motor Control Module has found an error in the pattern received from the Rotor
Position Sensor. Likely causes of this fault are a bad connection on the harness between
the Rotor Position Sensor and the Motor Control Module, or a faulty Rotor Position Sensor.
Primary Source:
Wiring.
Action:
Check for corrosion on the RAST connector of the Rotor Position
Sensor and the Motor Control Module connector.
Secondary Source:
Rotor Position Sensor.
Action:
Check the Rotor Position Sensor with an R.P.S. tester. Replace if
faulty.
Tertiary Source:
Motor Control Module.
Action:
Replace Motor Control Module.
Quaternary Source:
Rotor
Action:
Ensure the correct rotor for this phase of machine has been fitted
(Refer to Section 2.7.2).
136. (10001000) Motor Stall
The Motor Control Module has been unable to start the motor. Possible causes of this fault
are: Faulty motor harness, faulty or jammed motor, seized bearings or seals, faulty Motor
Control Module, faulty Rotor Position Sensor or harness.
Primary Source:
Wiring.
Action:
Measure/check the motor harness, connectors and motor for
discontinuity. This can be done by taking a resistance measurement
between phases of the motor harness at the Motor Control Module
end. Nominal resistance should be around 32
W
.
Secondary Source:
Motor.
Action:
1) Check free rotation of the agitator and basket by rotating by hand.
Bearings and seals may be seized.
2) Check the Rotor Position Sensor and associated harness for
water, mechanical damage or corrosion.
Tertiary Source:
Motor Control Module.
Action:
If the primary and secondary checks pass inspection, then replace
the Motor Control Module.
160. (10100000) Basket Engaged
The basket has re-engaged itself during agitate. Possible causes for this are a leak in the
air bell, the basket is over-loaded with clothes, the clutch has jammed or is fouled with a
foreign object.
Primary Source:
Mechanical.
Action:
1) Check that the rotating basket assembly is not jammed to the
agitator with any foreign object that may be caught under the
agitator skirt.