478182
36
6.2.5 Restart/Recycle
Features Permanently Programmed
It is possible for the Restart Feature to be disabled, or the Recycle Feature to be enabled, or a
combination of both to be permanently programmed into the memory of the electronics so that in
the event of a power cut the electronics will remember the setting.
The factory settings are:
•
Restart is enabled
•
Recycle is disabled
If a machine is encountered with the Restart/Recycle features not set to the factory defaults, the
machine must be re-programmed using following steps;
1. Enter diagnostic mode by pressing and holding the
HI-EFFICIENCY
button and then
pressing the
SELECT
button. Keep the buttons pressed for at least 2 seconds, after which
time two beeps will be heard and a screen showing 'Service' & 'Control' will appear.
2. Using the arrow buttons, highlight the 'Control' screen, then press
SELECT
.
3. To enable/disable the Restart feature permanently, press and hold the
LEFT SCROLL
ARROW
for three seconds until a beep is heard.
4. To enable/disable the Recycle feature permanently, press and hold the
RIGHT SCROLL
ARROW
for three seconds until a beep is heard.
6.3 Data
Download
To activate the data download, enter the diagnostic mode with the power on at the power point and
off at the console, press and hold the
HI-EFFICIENCY
and
SELECT
buttons. Keep the buttons
pressed for at least 2 seconds, after which time two beeps will sound. Then press the
START/PAUSE
button. The LED above the High Efficiency button will be on and flickering.
Place the download pen over this LED and follow the instructions supplied with the data download
program.
LED for data download