Fisher Aircon Solutions FSL-124HF Скачать руководство пользователя страница 7

Indoor air flow (Hi/Lo)     

m

3

/h 1000/850 

1250/1050 

Indoor noise level (Hi/Lo) 

dB(A) 

41/38 

45/42 

Dimension (W*H*D)     mm 

1330X240X505 

1530X240x505 

Packing   (W*H*D)   

mm 

1465X370X655 

1680X370X655 

Indoor unit 

Net/Gross weight       

kg 

35/42 

43/50 

Model  

 

YDK53-6K 

YDK53-6H 

Brand  

 

WELLING 

WELLING 

Input            

93 

140 

Capacitor        

uF 

2.5 

Outdoor fan motor 

Speed         

r/min 

800 

800 

Number of rows 

 

Tube pitch(a)x row 

pitch(b)   

mm 25.4X22 

25.4x22 

Fin spacing           

mm 

1.4 

1.5 

Fin type (code) 

 

Hydrophilic aluminium

Hydrophilic 

aluminium 

Tube outside dia.and 

type  

mm 

Ф

9.53, innergroove tube

Ф

9.53, innergroove 

tube 

Coil length x height x 

width   

mm 638X660X44  850X810X44 

Outdoor coil 

Number of circuits 

 

Outdoor air flow             

m

3

/h 2000 

3000 

Outdoor noise level         

dB(A) 

48 

52 

Dimension(W*H*D) mm  845X695X335  895X860X330 

Packing  (W*H*D) 

mm 

965X847X395 

972X987X406 

Outdoor unit 

Net/Gross weight   

kg 

55/58 

79/90 

Refrigerant type                 

R407C/2050 

R407C/2500 

Design pressure                       

MPa 

1.2/2.8 

1.2/2.8 

Liquid side/ Gas side      mm(inch)

Ф

6.35/

Ф

12.7 

(1/4”-1/2”) 

Ф

9.53/

Ф

16 

(3/8”-5/8”) 

Max. refrigerant pipe 

length    

m 15 

15 

Refrigerant piping 

Max. difference in level 

Connection wiring        

mm

2

No No 

Plug type 

 

No 

No 

Controller  

Remote 

Remote

 

Operation temp                             

 

17-30 17-30 

Ambient temp                               

 

—7-45 —7-45 

Notes: 1. Nominal cooling capacities are based on the following conditions: 

               Indoor temp: 27°CDB, 19°CWB; Outdoor temp: 35°CDB; Equivalent ref. Piping: 8m(horizontal) 
               2. Nominal heating capacities are based on the following conditions: 
               Indoor temp: 20°CDB; Outdoor temp: 7°CDB, 6°CWB; Equivalent ref. Piping: 8m(horizontal) 

3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an 
anechoic room 

 

- 6 -

Содержание FSL-124HF

Страница 1: ...TECHNICAL SERVICE MANUAL DUCT SLIM TYPE AIR CONDITIONER FSL 124HF FSL 184HF FSL 244HF FI SM 040823...

Страница 2: ...Table 9 Part 6 Outlines and Dimension 12 Part 7 Electric Control Functions 15 Part 8 Wiring Diagram 24 Part 9 Installation 24 Part 10 Servicing and Maintenance 27 Part 11 Exploded view 29 NOTICE Spec...

Страница 3: ...Part 1 Product Features Quietest operation low noise Thin design space saving Easy to operate remote control 2...

Страница 4: ...Supplier TOSHIBA GUANG DONG Capacity Btu h 14600 14800 Input W 1400 1430 Rated current RLA A 6 5 Locked rotor Amp LRA A 7 5 Thermal protector UP3RE0591 T56 Capacitor uF 35 Compressor Refrigerant oil m...

Страница 5: ...Packing W H D mm 890 655 355 Outdoor unit Net Gross weight Kg 40 45 Refrigerant type R407C g 1330 Design pressure MPa 1 2 3 5 Liquid side Gas side mm inch 6 35 12 7 1 4 1 2 Max refrigerant pipe lengt...

Страница 6: ...OREA Capacity Btu h 20130 20267 29000 Input W 1980 2105 2760 Rated current RLA A 9 7 10 3 12 4 Locked rotor Amp LRA A 50 61 Thermal protector INTERNAL TYPE INTERNAL TYPE Capacitor uF 40 60 Compressor...

Страница 7: ...48 52 Dimension W H D mm 845X695X335 895X860X330 Packing W H D mm 965X847X395 972X987X406 Outdoor unit Net Gross weight kg 55 58 79 90 Refrigerant type g R407C 2050 R407C 2500 Design pressure MPa 1 2...

Страница 8: ...igh airflow FSL 124HF FSL 184HF Octave band center frequency Hz Sound pressure level dB 0dB 0 0002 bar Audibility limits of continuous white sound FSL 244HF Octave band center frequency Hz Sound press...

Страница 9: ...Part 4 Operation Range Ensure the operating temperature is in allowable range 8...

Страница 10: ...4 89 4 68 4 51 4 26 4 08 3 96 3 83 Sensitive capacity kW 3 91 3 74 3 61 3 40 3 27 3 17 3 06 32 C D 23 C W Input kW 1 13 1 29 1 45 1 61 1 77 1 93 2 09 Model FSL 124HF HEATING OUTDOOR TEMPERATURE Indoor...

Страница 11: ...6 10 5 85 5 67 5 49 Sensitive capacity kW 5 61 5 36 5 17 4 88 4 68 4 53 4 39 32 C D 23 C W Input kW 1 77 2 02 2 28 2 53 2 78 3 04 3 29 Model FSL 184HF HEATING OUTDOOR TEMPERATURE Indoor Conditions 24...

Страница 12: ...8 28 7 95 7 70 7 45 Sensitive capacity kW 7 62 7 29 7 02 6 62 6 36 6 16 5 96 32 C D 23 C W Input kW 2 50 2 85 3 21 3 57 3 92 4 28 4 63 Model FSL 244HF HEATING OUTDOOR TEMPERATURE Indoor Conditions 24...

Страница 13: ...Part 6 Outlines and Dimension 7 1 Indoor unit FSL 124HF FSL 184HF 12...

Страница 14: ...FSL 244HF 7 2 Outdoor unit FSO 124HF 13...

Страница 15: ...FSO 184HF 12 5 FSO 244HF A BODY DIMENSION B BODY DIMENSION C INSTALL BOLTS D INSTALL BOLTS E INSTALL BOLTS F INSTALL BOLTS G BASE FOOT H WATER RECEIVER 895 300 330 590 163 141 355 1013 14...

Страница 16: ...ion 3 1 1 The manual operation mode is controlled through manual pad in the wind in take grid including such two modes as manual action and manual cooling Push the manual pad for each switchover the o...

Страница 17: ...er to manual cooling mode 3 2 Heating Mode 3 2 1 Four way valve opens at once while defrosting process closes 3 2 2 Condition for the compressor action Ts set temperature Ta room temperature Condition...

Страница 18: ...es 3 3 1 3 3 Temperature of outdoor coil T3 is up to 20 C 3 3 1 4 Ending Action of Defrost 3 3 1 4 1 Outdoor fan and four way valve are open 3 3 1 4 2 Compressor keeps on continuously 3 3 1 4 3 Indoor...

Страница 19: ...3 6 4 Protective condition is actived 3 7 Fan Only Mode 3 7 1 Under this mode four way valve compressor and outdoor fan are shut down 3 7 2 High Low Auto fan can be switched over through manual contro...

Страница 20: ...shut down for protection c When there are 4 times compressor protection within one hour the A C will be shut down meanwhile the operation light and timer light will be turned on the defrosting light...

Страница 21: ...rent protection of the compressor occurs 4 times in 1h Lamps of operation timer defrosting only fan flashing simultaneously at 5Hz Whole unit is shut down It cannot recover unless power is cut off 2 p...

Страница 22: ...4 C N 1 C N 24 R T2 R T1 T4 XT1 C AP1 FAN 1 L 3 2 N 1 N XT1 KM 1 KM 1 4 XT2 FSO 124HF Outdoor unit 4 W AY VALVE BLU E TO I N D O O R U N I T XT1 W H I TE BLU E BLAC K R ED Y G BLU E R ED Y G Y G BLAC...

Страница 23: ...FSL 184HF Indoor unit FSO 184HF Outdoor unit 22...

Страница 24: ...FSL 244HF Indoor unit 3 1 N L 2 XT1 XS1 XS3 XT1 XT2 CAP1 FAN1 XP1 XP3 RT2 RT1 CN1 CN16 T4 FSO 244HF Outdoor unit XT3 VALVE R T3 XT1 XT2 XS1 XP1 KM 1 FAN C AP2 C O M P C AP1 23...

Страница 25: ...uit of the cool discharge Comply to the installation clearance recommended Don t put the indoor unit where there is direct sunlight on unit Make sure the location is suitable for piping and drainage F...

Страница 26: ...pipe immediately in 5 minutes If the nuts have been loosened for a long time dusts and other impurities may enter the pipe system and may cause malfunction later So please expel the air out of the pi...

Страница 27: ...age fits the rated voltage of the air conditioner There is no obstacle at the outlet and inlet of the outdoor and indoor units The gas side and liquid side stop values are both opened The air conditio...

Страница 28: ...Cause Solutions Power failure Wait for the comeback of power Power switch is open Switch on the power Fuse of power switch may have blown Replace the fuse Batteries remote of controller are exhausted...

Страница 29: ...ck whether the timer operation has come to an end when the OFF TIMER is indicated on the display The air conditioner operation stops since the set time elapsed The ON TIMER indicators go off after a l...

Страница 30: ...lector 1 25 4 Wire joint 1 9 Capacity 1 25 5 Relay 1 10 Capacitor box 1 26 E Parts box cover 1 11 Right fixing clamp for motor 1 27 Pipe supporting board 1 12 Left fixing clamp for motor 1 28 Pipe cla...

Страница 31: ...iring 1 7 Foam over holder for motor 1 25 Gas pipe valve 1 8 Cover 1 26 Liquid pipe valve 1 9 Fixing clamp for condenser 2 27 Separating board 1 10 Condenser 1 28 Compressor 1 11 Antivibration sponge...

Страница 32: ...board II 1 10 Capacitor box 1 28 Holder for remote controller 1 11 Axis 1 29 Remote controller 1 12 Bearing 1 30 E Parts box cover 1 13 Bearing seat 1 31 Pipe supporting board 1 14 Fan ass y 3 32 Pip...

Страница 33: ...egregator 1 9 Support board Left Side 1 26 Four way Valve 1 10 Rear Net 1 Four way Valve Solenoid 1 11 Support board Back side 1 27 High Pressure Valve 1 4 in 1 12 Handle 2 28 Capillary pipe Ass y 1 1...

Страница 34: ...33 33...