background image

© Copyright 2001-2021  fischertechnik GmbH   |   Klaus-Fischer-Straße 1   |   72178 Waldachtal

14

ROBOTICS

 

TXT 4.0 CONTROLLER

  

fischertechnik TXT Operating manual_EN  |  10. November 2021, 9:18 PM

MASTER OR EXTENSION

This symbol indicates whether the Controller is set at the Master or Extension.  
M = operated as the Master (LED of the ON/OFF button illuminated blue); E

 

= operated as Extension (LED of the 

ON/OFF button illuminated green).

Changes can be made in the 

Settings | Properties

 menu.

Master: 
The Controller set as the master receives control commands directly from the PC and transmits them to the 
extensions.

Extension:  
The Controller set as the extension receives control commands only from the master. 
Up to 9 extensions are possible. 

Single: 
In this mode, using the CAN interface to connect additional TXT 4.0 Controllers as expansions is not supported. 
This results in an energy savings of up to 10%, and therefore a longer battery life.

TIME

Displays the current set time. This can be changed using the 

Settings| Date and time

 menu.

CONTROL ELEMENTS 

The user can navigate through the menu by touching the control elements.

One step back 

in menu

Scroll/swipe 

To scroll through longer menus (appears only if the menu requires).

Back to main menu

Содержание ROBOTICS TXT 4.0

Страница 1: ...ROBOTICS TXT 4 0 CONTROLLER Operating manual...

Страница 2: ...equirements 11 Supply the Controller with power 11 Switching the Controller on and off 11 Switch on process 11 Switch off process 12 Setting the Controller 12 Menu overview 12 Menu in detail 13 Status...

Страница 3: ...Controller S1 S2 S3 SD USB1 USB2 9V OUT IN 9V 9V OUT Program1 12 30 PROGRAMM NAME STOPPED PROGRAM 01 Program Running Test Info Settings File Program1 12 30 01 0 0 0 10 10 1 1 0 11 1 0 0 0 0 0 1 01 US...

Страница 4: ...on Insert batteries with the correct polarity Connection terminals may not be short circuited The ROBOTICS TXT 4 0 Controller may only be operated with a fischertechnik power supply such as the Batter...

Страница 5: ...in many different applications A USB Host port is also provided and can be used to connect the fischertechnik USB camera or USB sticks for instance Up to nine additional controllers can be connected...

Страница 6: ...n be connected and controlled In addition the Controller can be expanded with additional devices ACTUATORS 9V 250 mA Motors Servos Compressors LEDs Buzzers Solenoid valves from the pneumatic building...

Страница 7: ...fischertechnik GmbH Klaus Fischer Stra e 1 72178 Waldachtal 07 ROBOTICS TXT 4 0 CONTROLLER fischertechnik TXT Operating manual_EN 10 November 2021 9 18 PM 04 Combination sensors Environmental sensors...

Страница 8: ...F TXT 4 0 Controller S1 S2 S3 SD USB1 USB2 9V OUT IN 9V 9V OUT Program1 12 30 PROGRAMM NAME STOPPED PROGRAM 01 Program Running Test Info Settings File Program1 12 30 01 0 0 0 10 10 1 1 0 11 1 0 0 0 0...

Страница 9: ...counting inputs record counting pulses up to 1 kHz 1000 pulses sec for instance from fischertechnik encoder motors These can also be used as digital inputs for instance for buttons 10 9V Out Supplies...

Страница 10: ...TXT 4 0 CONTROLLER fischertechnik TXT Operating manual_EN 10 November 2021 9 18 PM Analog sensors 0 10V color sensors display the value in in mV millivolt Ultrasound distance sensors 14 Servo connect...

Страница 11: ...tery Pack not included in the scope of delivery Connect the 9V DC 2 3 2 5A power supply to the 9V IN DC port see number 5 in the section Overview of connections In this case the power supply from the...

Страница 12: ...To deactivate the Controller press and hold the ON OFF button 11 for approx 3 seconds until the button is illuminated red Now release the ON OFF button and the Controller will be switched off After s...

Страница 13: ...e In this mode using the CAN interface to connect additional TXT 4 0 Controllers as expansions is not supported in order to reduce power consumption 02 Wi Fi Client mode activated deactivated connecti...

Страница 14: ...eives control commands directly from the PC and transmits them to the extensions Extension The Controller set as the extension receives control commands only from the master Up to 9 extensions are pos...

Страница 15: ...01 START PROGRAM The selected program is started If no program is selected a blue bar appears After the program is started the display switches to green If the program is stopped the bar is red 02 FI...

Страница 16: ...the file name the Load button will turn green and the program can be loaded If the user presses the arrow beside the program name they will see the following options Load If this function is activated...

Страница 17: ...4 0 CONTROLLER fischertechnik TXT Operating manual_EN 10 November 2021 9 18 PM Auto start If this function is activated the selected program will start automatically once the power sup ply to the Cont...

Страница 18: ...connected the Controller must be restarted to detect all extensions during the boot process Language The menu language can be changed here Network Wireless connections can be activated and deactivate...

Страница 19: ...to the fischertechnik Cloud A pairing code is displayed that must be entered in the fisch ertechnik Cloud www fischertechnik cloud com Pairing code Pairing successful Updates Complete operating system...

Страница 20: ...scher Stra e 1 72178 Waldachtal 20 ROBOTICS TXT 4 0 CONTROLLER fischertechnik TXT Operating manual_EN 10 November 2021 9 18 PM 04 TEST Touch Test the touch function Sound Test Calls up a display where...

Страница 21: ...XT 4 0 CONTROLLER fischertechnik TXT Operating manual_EN 10 November 2021 9 18 PM 05 INFO Calls up an info window with data on the Controller such as its serial number Wi Fi address and Bluetooth iden...

Страница 22: ...rocedure for downloading programs are described in the Help section for the ROBO Pro Coding software If a program is loaded from ROBO Pro Coding to the Controller it can be launched immediately The pr...

Страница 23: ...ack The new Controller can be assigned the function of an Extension 1E 9E using the display This setting can be changed in the Settings Role Extension menu Connect the Controllers to one another using...

Страница 24: ...phone by selecting the Controller in the Settings Wi Fi or Bluetooth menu iOS or Settings connections Wi Fi or Bluetooth Android NOTICE ON DATA TRANSMISSION QUALITY The range is approx 10 m and is dep...

Страница 25: ...supply into the 9 V IN input port 5 on the Controller Turn on the Controller using the on off switch 11 Hold the switch down for approx 3 seconds until the display is illuminated CONNECTING THE TXT 4...

Страница 26: ...l To connect to the ROBOTICS TXT 4 0 Controller click the network symbol shown in the symbol bar at the bottom right of the PC screen The following window will appear Select TXT4 0 and then click Conn...

Страница 27: ...anual uses the display in Windows 10 CONNECT THE TXT 4 0 CONTROLLER TO A PC VIA BLUETOOTH The ROBOTICS TXT 4 0 Controller must be switched on and Bluetooth must be active in the menu under the Network...

Страница 28: ...on the Controller TXT 4 0 under Network Bluetooth Pairing code Click Connect the connection to the device will be completed In the Windows menu click Connect using and then Access points to activate...

Страница 29: ...the section Menu in detail Status bar If an update is available the newest available version is displayed such as Release 3 1 0 in Settings Updates under Online updates Select the newest version and...

Страница 30: ...M R dual Cortex A7 650 MHz Cortex R M4 programmable with ROBO Pro Coding Software Python or C Compiler not included OPERATING SYSTEM Linux based open source incl Linux camera driver image processing s...

Страница 31: ...an 3 3 volts may damage the device SIGNAL INPUTS AND OUTPUTS 8 universal inputs Digital analog 0 9 V DC analog 0 5 k 4 fast counting inputs Digital frequency up to 1kHz 4 motor outputs 9 V 250 mA Spee...

Страница 32: ...days after delivery otherwise any warranty claims due to obvious defects will be excluded Warranty claims cannot be asserted due to an insignificant defect in the Controller Furthermore the customer...