Electrical Connections, Switching Outputs

Switching outputs: 

Switching  output  1  is  configured  by  parameters 

R1A,

R1E, R1D,

 and 

R1F

.

Switching  output  2  is  configured  by  parameters 

R1A,

R1E, R1D,

 and 

R1F

.

Power supply voltage and output signal load: 

Nominal supply voltage and the operating supply voltage
range are indicated under 11. Specifications.

The  maximum  output  signal  loads  are  indicated  under
11. Specifications.

The signal ground line is internally connected to the ins-
trument ground, and serves only as an alternative ground
connection for the output signal. This usually increases
the noise margin.

6.

Maintenance

The instrument is inherently maintenance-free.

However, to ensure reliable operation and maximize the
operating life  of the instrument, it is recommended  that
the  instrument,  its  external  electrical  and  process  con-
nections, and external connected devices be regularly in-
spected, e.g.:

Check the display.

Check the switching function in connection with exter-
nal devices.

Check all pressure connections for leak-tightness.

Check the integrity of all electrical connections of the
instruments.

Inspection and test schedules depend on operating and
site  conditions.  The  operating  manuals  of  other  equip-
ment to which the transmitter is connected must be read
thoroughly to ensure that all of them work correctly when
connected together.

7.

Transport

The product must be protected against shock and vibra-
tion during transport. It must therefore be properly pak-
ked,  preferably  in  the  original  factory  packaging,
whenever it is to be transported. 

8.

Service

Any  defective  devices  or  devices  with  missing  parts
should be retourned to Fischer Mess- und Regeltechnik
GmbH. For quick service contact our service department.

Remaining medium in and on dismant-
led measuring instruments may cause
danger  to  persons,  environment  and
equipment.  Take  reasonable  precau-
tions! Clean the instrument thoroughly
if necessary.

9.

Accessories

M12 connectors with pre-wired cable lengths 
(on request)

PC serial interface adaptor with software: 
model EU03.F300

10.

Disposal

Protect your environment!

Use  the  product  in  accordance  with
relevant regulations.  Please  be aware
of environmental consequences of dis-
posal  at  the  end  of  the  product's  life,
and take care accordingly. 

Contact: EK Engineering (India)
Web: www.ekeindia.com
Email: [email protected]

All manuals and user guides at all-guides.com

Содержание DE45 series

Страница 1: ...d inspection of this product must have the qualifications training and experience necessary to carry out such work on this type of equipment Qualified personnel are people who are able to ju dge deleg...

Страница 2: ...applies to the use of unautho rized spare parts for repair maintenance of the product Any modifications to this product if and as necessary should be done only by Fischer Mess und Regeltechnik GmbH 1...

Страница 3: ...ing system must meet specifications for zone 2 class 3 Electrical connections must comply with relevant international and local regulations and norms re lating to electrical and instrumentation instal...

Страница 4: ...lighted symbols to the right of the digital dis play To change the unit of measurement first press then search for parameter EIN using Next press again and select another unit of measurement using or...

Страница 5: ...ut signal value set as parameter oEr However it should be understood that not all instrument fault and er ror conditions can be detected and signaled by the self diagnostic functions of the instrument...

Страница 6: ...ast significant right most digit The value of the set up parameter R1D determines the delay time for switching output 1 after the measured value reaches the switching point The delay value can be sele...

Страница 7: ...e measured variable corresponding with the minimum value of the output signal 0 V 0 mA or 4 mA depending on the instrument version ME Measuring range end point The value of the measured variable corre...

Страница 8: ...the instruments Inspection and test schedules depend on operating and site conditions The operating manuals of other equip ment to which the transmitter is connected must be read thoroughly to ensure...

Страница 9: ...20 70 C IP 65 acc to DIN EN 60529 Electrical Data Nominal supply voltage Operating supply voltage Output signal 24 V DC AC 12 32 V DC AC 0 20 mA 4 20 mA 0 10 V DC 3 wire Output signal load For output...

Страница 10: ...h 1 2 activation point de activation point response time delay 0 0 100 0 secs logic N O or N C Measurement unit selection mbar Pa free unit start value end value and decimal place for free unit Zero s...

Страница 11: ...ge output 0 10 V DC linear 3 wire C Current output 4 20 mA linear 3 wire P Supply Voltage 24 V DC AC nominal 12 32 V DC AC K Display Switching output 3 digit LED 2 potential free semiconductor switch...

Страница 12: ...12 14 Declaration of Conformity Contact EK Engineering India Web www ekeindia com Email india eke gmail com All manuals and user guides at all guides com...

Отзывы: