1.5 

Unauthorised Modification 

Modifications of or other technical alterations to the 
instrument  by  the  customer  are  not  permitted. This 
also  applies  to  replacement  parts.  Any  modifica-
tions  /  alterations  required  shall  be  carried  out  by 
Fischer Mess- und Regeltechnik GmbH only. 

1.6 

Inadmissible Modes of Operation 

The operational safety of this device can only be 
guaranteed if it is used as intended. The device 
model must be suitable for the medium used in the 
system. The limit values given in the technical data 
may not be exceeded. 

1.7 

Safe working practices for mainte-
nance and installation work 

The safety instructions given in this operating man-
ual,  any  nationally  applicable  regulations  on  acci-
dent prevention and any of the operating company's 
internal work, operating, and safety guidelines must 
be observed.  

The  operating  company  is  responsible  for  ensuring 
that all required maintenance, inspection and instal-
lation  work  is  carried  out  by  qualified  specialized 
personnel. 

1.8 

Explanation of the symbols 

 

WARNING! 

… indicates a potentially dangerous 
situation, non-observance of which 
could endanger persons, animals, the 
environment or objects. 

 

 

 

INFORMATION! 

… highlights important information for 
efficient and fault-free operation. 

 

 

 

TIP! 

… highlights recommendations that 
may be useful but which are not nec-
essarily required in specific situations. 

 

 

Intended use 

Display  and  switching  device  for  differential  pres-
sure of gaseous media. The instrument is to be ex-
clusively  used  for  the  applications  agreed  between 
the manufacturer and user. 

Description of the product and func-
tional description 

3.1 

Function diagram 

 

 

3.2 

Design and mode of operation 

The  device  is  based  on  two  piezo-resistive  sensor 
elements  that  are  suitable  for  measuring  overpres-
sure,  underpressure  and  differential  pressure.  The 
pressures  to  be  compared  directly  act  on  a  silicon 
diaphragm  equipped  with  piezo-resistive  resistors. 
In  case  of  equal  pressure,  the  measuring  dia-
phragm  is  in  its  idle  state.  In  case  of  pressure  dif-
ference,  the  force  acting  on  the  measuring  mem-
branes  causes  it  to  be  moved  towards  the  side  of 
the  lower  pressure.  This  movement  of  the  dia-
phragm  induces  a  change  of  resistance,  which  is 
evaluated  by  the  device's  electronics  and  trans-
formed  into  signals  on  the  display,  switch  contacts 
and an output signal. 

The electronics analyses both sensor signals sepa-
rately.  The  signal  from  the  first  sensor  influences 
the  switching  output  1  and  the  optional  output  sig-
nal, the output signal from the second sensor, only 
acts on the switching output 2. 

Installation and assembly 

The  unit  is  designed  for mounting  on  flat assembly 
plates. For screw connection to the assembly plate, 
the  device  features  four  assembly  bores  on  its 
back,  which  can  be  used  for 

3.5  mm  tapping 

screws. 

Optionally, the device can  be delivered with a  wall-
mounting plate (see 13, order code). 

At  the  factory,  the  device  is  calibrated  for  vertical 
installation,  but  the  installation  position  is  arbitrary. 
For installation positions deviating from the vertical, 
the  zero-point  signal  can  be  corrected  by  the  inte-
grated zero-point adjuster (see 5.3.3). 

The enclosure protection type IP 65 is only guaran-
teed, if a suitable power supply cable is used. 

Содержание DE44

Страница 1: ...zed personnel familiar with the in stallation commissioning and operation of this product Specialized personnel are persons who can assess the work they have been assigned and recognize potential dang...

Страница 2: ...eed between the manufacturer and user 3 Description of the product and func tional description 3 1 Function diagram 3 2 Design and mode of operation The device is based on two piezo resistive sensor e...

Страница 3: ...ilters need to be installed at suitable points The pressure sensing lines need to be kept as short as possible and installed without sharp bends to avoid interfering delay times If the pressure sensin...

Страница 4: ...tions step by step Depending on the device model 1 some menu items may not be available For example all characteristic curve functions are faded out in the menu if the de vice does not have a signal o...

Страница 5: ...isplay output signal and switch points but not on the measuring cell it self This parameter can be used to set the reaction time to the pressure jumps The value range is 0 0 s to 100 0 s But with maxi...

Страница 6: ...means of hydrostatic pressure measure ments are two typical examples of this In these cases you might want to change the output signal of the transmitter to a non linear characteristic curve so that t...

Страница 7: ...ue 000 cancels the password function If a password has been issued the text PAS appears after ESc and and you need to enter the correct value using and You will only arrive at all other menu items aft...

Страница 8: ...e of the de vice can be shown sensibly MA Start of measuring range The measuring value is set in that the output signal is minimal e g 0V 0mA or 4mA ME End of measuring range The measuring value is se...

Страница 9: ...must not be exposed to mechanical shocks It shall be transported only in packaging specifically intended for transport 8 Service All damaged or faulty devices shall be directly sent to our repair depa...

Страница 10: ...4 20 mA 0 10 V DC Admissible apparent ohmic resistance RL Ub 4 V 0 02 A Ub 26V RL 1100 Ub 26V RL 2 K Ub 15V RL 10 K Ub 12 15V Characteristic curve can be programmed Power consumption approx 2 W VA Di...

Страница 11: ...ith 3 30 support points Password 001 999 000 no password protection Comments 0 For values from 0 2 the display switches between dP1 and dP2 rhythmically 1 Measuring values around zero are set to zero...

Страница 12: ...5 6 0 40 mbar 5 7 0 60 mbar 5 8 0 100 mbar 5 9 2 5 2 5 mbar A 6 4 4 mbar A 7 6 6 mbar A 8 10 10 mbar A 9 16 16 mbar B 1 25 25 mbar B 2 40 40 mbar C 5 60 60 mbar B 3 100 100 mbar B 4 0 400 Pa D 7 0 60...

Страница 13: ...40 mbar 5 7 0 60 mbar 5 8 0 100 mbar 5 9 2 5 2 5 mbar A 6 4 4 mbar A 7 6 6 mbar A 8 10 10 mbar A 9 16 16 mbar B 1 25 25 mbar B 2 40 40 mbar C 5 60 60 mbar B 3 100 100 mbar B 4 0 400 Pa D 7 0 600 Pa D...

Страница 14: ...sured value display contact elements 3 1 2 digit LED 2 relay contacts 3 3 1 2 digit LED 2 semiconductor switches 6 Electrical connection M12 plug connection M Assembly option Standard attachment boreh...

Страница 15: ...14 Declaration of Conformity...

Страница 16: ...ject to change without notice Changements techniques sous r serve Fischer Mess und Regeltechnik GmbH Bielefelder Str 37a D 32107 Bad Salzuflen Tel 49 5222 9740 Fax 49 5222 7170 eMail info fischermesst...

Отзывы: