Digital 2-channel differential pressure switch/transmitter 
with 3 ½-digit LED display 

DE44 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure connection 

 

 

 

 

 

 

 

 

 

 

 

 

 

Aluminium screw connection for 6 / 4 mm hose ............................................ > 

 

 

 

 

 

 

 

Aluminium screw connection for 8 / 6 mm hose ............................................ > 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical output signal (only channel 1) 

 

 

 

 

 

 

 

 

 

 

 

 

 

without analogue electrical output signal ...................................................................... > 

 

 

 

 

 

 

– 20 mA 3-wire (STANDARD) ................................................................................... > 

 

 

 

 

 

 

– 10 V DC 3-wire (STANDARD)  ............................................................................... > 

 

 

 

 

 

 

– 20 mA 3-wire (STANDARD) ................................................................................... > 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating voltage 

 

 

 

 

 

 

 

 

 

 

 

 

 

24 V DC/AC (12 - 32 V DC/AC) ............................................................................................ > 

 

 

 

 

 

 

 

 

 

 

 

 

Measuring unit 

 

 

 

 

 

Standard pressure units .............................................................................................................. > 

 

 

 

 

 

 

 

 

 

 

Measured value display / contact elements 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 1/2-digit-LED 

– 2 relay contacts ........................................................................................................ > 

 

 

 

3 1/2-digit-LED 

– 2 semiconductor switches ........................................................................................ > 

 

 

 

 

 

 

 

 

Electrical connection 

 

 

 

 

 

 

 

 

 

 

 

 

 

M12 plug connection ................................................................................................................................... > 

 

 

 

 

 

 

Assembly option 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard (attachment boreholes on rear side) ...................................................................................................... > 

 

Wall mounting ...................................................................................................................................................... > 

 

 

 

 

13.1  Accessories 

Order Code 

Designation 

No. of 
Poles 

Usage 

Length 

06401993 

Connection cable with M12 connector 

4-pole 

for switching outputs 

2 m 

06401994 

Connection cable with M12 connector 

4-pole 

for switching outputs 

5 m 

06401995 

Connection cable with M12 connector 

5-pole 

for supply / signal 

2 m 

06401996 

Connection cable with M12 connector 

5-pole 

for supply / signal 

5 m 

EU03.F300 

Adapter for parameterization via PC software 

 

 

 

Содержание DE44

Страница 1: ...zed personnel familiar with the in stallation commissioning and operation of this product Specialized personnel are persons who can assess the work they have been assigned and recognize potential dang...

Страница 2: ...eed between the manufacturer and user 3 Description of the product and func tional description 3 1 Function diagram 3 2 Design and mode of operation The device is based on two piezo resistive sensor e...

Страница 3: ...ilters need to be installed at suitable points The pressure sensing lines need to be kept as short as possible and installed without sharp bends to avoid interfering delay times If the pressure sensin...

Страница 4: ...tions step by step Depending on the device model 1 some menu items may not be available For example all characteristic curve functions are faded out in the menu if the de vice does not have a signal o...

Страница 5: ...isplay output signal and switch points but not on the measuring cell it self This parameter can be used to set the reaction time to the pressure jumps The value range is 0 0 s to 100 0 s But with maxi...

Страница 6: ...means of hydrostatic pressure measure ments are two typical examples of this In these cases you might want to change the output signal of the transmitter to a non linear characteristic curve so that t...

Страница 7: ...ue 000 cancels the password function If a password has been issued the text PAS appears after ESc and and you need to enter the correct value using and You will only arrive at all other menu items aft...

Страница 8: ...e of the de vice can be shown sensibly MA Start of measuring range The measuring value is set in that the output signal is minimal e g 0V 0mA or 4mA ME End of measuring range The measuring value is se...

Страница 9: ...must not be exposed to mechanical shocks It shall be transported only in packaging specifically intended for transport 8 Service All damaged or faulty devices shall be directly sent to our repair depa...

Страница 10: ...4 20 mA 0 10 V DC Admissible apparent ohmic resistance RL Ub 4 V 0 02 A Ub 26V RL 1100 Ub 26V RL 2 K Ub 15V RL 10 K Ub 12 15V Characteristic curve can be programmed Power consumption approx 2 W VA Di...

Страница 11: ...ith 3 30 support points Password 001 999 000 no password protection Comments 0 For values from 0 2 the display switches between dP1 and dP2 rhythmically 1 Measuring values around zero are set to zero...

Страница 12: ...5 6 0 40 mbar 5 7 0 60 mbar 5 8 0 100 mbar 5 9 2 5 2 5 mbar A 6 4 4 mbar A 7 6 6 mbar A 8 10 10 mbar A 9 16 16 mbar B 1 25 25 mbar B 2 40 40 mbar C 5 60 60 mbar B 3 100 100 mbar B 4 0 400 Pa D 7 0 60...

Страница 13: ...40 mbar 5 7 0 60 mbar 5 8 0 100 mbar 5 9 2 5 2 5 mbar A 6 4 4 mbar A 7 6 6 mbar A 8 10 10 mbar A 9 16 16 mbar B 1 25 25 mbar B 2 40 40 mbar C 5 60 60 mbar B 3 100 100 mbar B 4 0 400 Pa D 7 0 600 Pa D...

Страница 14: ...sured value display contact elements 3 1 2 digit LED 2 relay contacts 3 3 1 2 digit LED 2 semiconductor switches 6 Electrical connection M12 plug connection M Assembly option Standard attachment boreh...

Страница 15: ...14 Declaration of Conformity...

Страница 16: ...ject to change without notice Changements techniques sous r serve Fischer Mess und Regeltechnik GmbH Bielefelder Str 37a D 32107 Bad Salzuflen Tel 49 5222 9740 Fax 49 5222 7170 eMail info fischermesst...

Отзывы: