Installation Instructions
Page 50 Panda PMS AGT-DC 4000 - Chapter D: Installation Instructions
D.5.3 Installation exhaust/water separator
If the exhaust/water separator was sufficiently highly installed, a goose neck is no longer neces-
sary. The exhaust/water separator fulfills the same function. If the "Supersilent" exhaust system
were installed correctly, the generator will not disturb your boat neighbour. The exhaust noise
should be nearly inaudible. The best result is reached, if the hose line, which derive the cooling
water, is relocate on a short way "falling" directly to the outlet and this outlet is under the water-
line.
If the thru-hull exhaust outlet has to be mounted far from the generator, an exhaust-water separa-
tor must definitely be installed. The sea water from the separator must then run along the shortest
possible path is the thru-hull outlet. For such long exhaust routes, the exhaust hose diameter
should also be increased from NW40mm to NW50mm in order to reduce the back-pressure. The
exhaust may have a length of over 10m (32 ft.) if the exhaust hose diameter is increased to
50mm. An additional outlet exhaust muffler close to the hull outlet will help further to reduce noise
emissions.
1.
Generator
2.
Water lock
3.
Exhaust/water separator
4.
Hull outlet exhaust
5.
Hull outlet water
6.
Sea cock
7.
Reducer
8.
Silencer
9.
Exhaust pipe
10. Exhaust pipe
11. Waterline
12. Water hose
13. Exhaust hose