Panda iControl
Page 88 - Chapter A: Panda iControl
Panel_iControl_eng.fm
Fischer Panda Datasheet
Following warnigs are displayed
A.6 Error warnings
Error warnings are shown in the display. The screen switch from the temperature to „High“.
Engine temp.
> 75 °C
Exhaust temp.
> 70 °C
Winding temp.
> 120 °C
Table 1: Warning table
Example for the warning on the display
(Winding temp. „HIGH“)
Fig. A.6-1: Display warning (winding temp „high“) - example
A.7 Errors
The least 5 errors are stored in the electronic memory and can be read out by the service technican..
Push the „enter“ button to quitt errors which has stopped the generator
Unexpected stop
Generator stops during operation or RPM droped under 1100 RPM (Fuel low, overload
ect.)
Fault: Oilpress
Oilpressure to low
Fault: Winding
Winding temp. over 135°C
Fault: Exhaust
Exhaust tem over> 75°C (PMS version) or>100°C(vehicles versions)
Fault: Cyl. Head
Cylinder head temp. over >90°C (PMS version) or >95°C (vehicles versions)
Starting Fail
Generator do not start after 10 sec.
Table 2: Fault table
Содержание Panda 6000i PMS
Страница 9: ...Panda 6000i PMS 230V 50Hz 6kW Fischer Panda GmbH Panda 6000i Part 1 Generator Manual ...
Страница 10: ...10 Current revision status Document Actual Panda 6000i generator_s01835_eng R01_16 1 09 Replace Revision Page ...
Страница 14: ...14 Socket wrench set Hexagon wrench keys ...
Страница 18: ...18 Intentionally Blank ...
Страница 91: ...Panda iControl Panel_iControl_eng fm Chapter A Panda iControl Page 91 A 9 2 Dimensions Fig A 9 2 1 Dimensions ...
Страница 92: ...Panda iControl Page 92 Chapter A Panda iControl Panel_iControl_eng fm Intentionally Blank ...
Страница 93: ...Panda_PMGi_6000_eng R0116 1 09 PMGi 6000 Fischer Panda GmbH Panda i series Part 3 PMGi 6000 inverter Manual ...
Страница 94: ...94 Current revision status Document Actual Panda_PMGi_6000_eng R01_16 1 09 Replace Revision Page ...
Страница 106: ...Panda PMGi 6000 Page 106 Chapter A Panda PMGi 6000 PGMi 6000_eng fm Fischer Panda Datasheet Intentionally Blank ...