Panda iControl
Panel_iControl_eng.fm
Chapter A: Panda iControl - Page 83
Fischer Panda Datasheet
Note
Regarding to the open electric board the iControl panel has a protectrive class IP00.
Builded in a control board with a siutable seal (f.e. Sikaflex) IP66 can be reached.
A.3 Buttons and display of the iControl
Fig. A.3-1: Buttons and diplay of the iControl
Warning! At the Electronic board is an voltage of 450V. Only special trained persons are
allowed to open the cover of the Electronic board. !!!DANGER TO LIVE!!!
2
4
1
3
2a
2b
2d
2c
2e
2f
2g
1.
Button „on/off“
2.
Display
2a. Load indication in %
2b. Oil pressure indication „OK“ oder „Fault“
2c. Engine temp. indication
2d. Exhaust elbow temp. indication
2e. Stator Winding temp. indication
2f. Engine rpm indication
2g. Operation hours
3.
Button „enter“
4.
Button „start/stop“
Содержание Panda 6000i PMS
Страница 9: ...Panda 6000i PMS 230V 50Hz 6kW Fischer Panda GmbH Panda 6000i Part 1 Generator Manual ...
Страница 10: ...10 Current revision status Document Actual Panda 6000i generator_s01835_eng R01_16 1 09 Replace Revision Page ...
Страница 14: ...14 Socket wrench set Hexagon wrench keys ...
Страница 18: ...18 Intentionally Blank ...
Страница 91: ...Panda iControl Panel_iControl_eng fm Chapter A Panda iControl Page 91 A 9 2 Dimensions Fig A 9 2 1 Dimensions ...
Страница 92: ...Panda iControl Page 92 Chapter A Panda iControl Panel_iControl_eng fm Intentionally Blank ...
Страница 93: ...Panda_PMGi_6000_eng R0116 1 09 PMGi 6000 Fischer Panda GmbH Panda i series Part 3 PMGi 6000 inverter Manual ...
Страница 94: ...94 Current revision status Document Actual Panda_PMGi_6000_eng R01_16 1 09 Replace Revision Page ...
Страница 106: ...Panda PMGi 6000 Page 106 Chapter A Panda PMGi 6000 PGMi 6000_eng fm Fischer Panda Datasheet Intentionally Blank ...