Panda iControl
Page 84 - Chapter A: Panda iControl
Panel_iControl_eng.fm
Fischer Panda Datasheet
A.4 Engine control
The iControl Panel and Electronic Board is for driving the Panda i-series generator. Push the „on/off“ button to
start the panel(1). The panel will come up in the „stand by mode“.
„stand by mode“
in the stand by mode the iControl checks the generator
- Display shows welcome screen
- the Led-Light will switch off after 2 min. (energie save)
- push the „enter“ button“ to reset the LED-Light timer
- start the generator with the „start/stop“ button --> „run mode“
- start the generator with the „automatic start“ option --> „run mode“
„run mode“
Generator was started with the “start/stop“ button or with the „automatic start option“
- Display light is on
- Display shows generator data
- stop the generator with the „start/stop“ button --> „standby mode“
- stop the generator with the „automatic start“ option --> „standby mode“
A.5 Operation manual
A.5.1 Daily routine checks before starting
1. Oil Level Control (ideal level: 2/3 of maximum).
AtTTENTION! OIL PRESSURE CONTROL!
True, the diesel motor automatically switches off when there is a lack of oil, but it is very damaging for the motor, if the oil level drops to
the lowest limit. Air can be sucked in suddenly when the boat rocks in heavy seas, if the oil level is at a minimum. This affects the
grease in the bearings. It is therefore necessary to check the oil level daily before initially running the generator. The oil level must be
topped up to the 2/3 of maximum level, if the level drops min. mark.
2. State of Cooling Water.
The external compensation tank should be filled up to a 1/3 level of in a cold state. It is very important that large expansion area
remains above the cooling water level.
3. Open Sea Cock for Cooling Water Intake.(if necessary)
For safety reasons, the seacock should be closed after the generator is switched off for a longer time. It should be re-opened before
starting the generator.
4. Check Raw water Filter.
The raw water filter must be regularly checked and cleaned. The impeller fatigue increases, if residual affects the raw water intake.
Содержание Panda 6000i PMS
Страница 9: ...Panda 6000i PMS 230V 50Hz 6kW Fischer Panda GmbH Panda 6000i Part 1 Generator Manual ...
Страница 10: ...10 Current revision status Document Actual Panda 6000i generator_s01835_eng R01_16 1 09 Replace Revision Page ...
Страница 14: ...14 Socket wrench set Hexagon wrench keys ...
Страница 18: ...18 Intentionally Blank ...
Страница 91: ...Panda iControl Panel_iControl_eng fm Chapter A Panda iControl Page 91 A 9 2 Dimensions Fig A 9 2 1 Dimensions ...
Страница 92: ...Panda iControl Page 92 Chapter A Panda iControl Panel_iControl_eng fm Intentionally Blank ...
Страница 93: ...Panda_PMGi_6000_eng R0116 1 09 PMGi 6000 Fischer Panda GmbH Panda i series Part 3 PMGi 6000 inverter Manual ...
Страница 94: ...94 Current revision status Document Actual Panda_PMGi_6000_eng R01_16 1 09 Replace Revision Page ...
Страница 106: ...Panda PMGi 6000 Page 106 Chapter A Panda PMGi 6000 PGMi 6000_eng fm Fischer Panda Datasheet Intentionally Blank ...