Tables
16.1.09
AGT-DC_PMS_144V_s01790_Operation instruction.R01 - Chapter F: Tables Page 71
F. Tables
F.1
Troubleshooting
GENERATOR OUTPUT VOLTAGE TOO LOW
If the generator delivers less than 24V current ("undervoltage"), there can be various reasons for this:
Cause
Solution
PGMi is overloaded.
Reduce the electrical load. (Switch off load)
Motor is not reaching the rated rpm.
Refer to "motor faults" section.
MOTOR DOES NOT TURN OVER WHEN STARTING
Cause
Solution
Battery main switch is switched off.
Check the position of the battery main switch, if neces-
sary switch on..
Battery voltage not sufficient.
Check that connection is firm and whether corrosion
has occurred..
Starting current fault.
The voltage of full batteries fall to a maximum of 11V.
The wiring is severed if the voltage does not drop. The
battery is discharged if the voltage drops further.
MOTOR TURNS OVER BUT DOES NOT START
Cause
Solution
Stop solenoid valve not opening.
Check wire connections and circuitry to solenoid valve.
(ref. DC wiring diagram: Relay K2, Fuse)
Fuel pump does not operate.
Check fuel-filter and pump: clean if necessary.
Lack of fuel.
Check fuel supply.
Glow-plugs not working correctly.
Check glow plugs and heating time.
Too much air in fuel lines.
Test fuel system for leakage. Bleed air from fuel system
(refer to section "Air-bleeding of the Fuel System").
Fuel filter blocked.
Replace fuel filter.
Low compression pressure.
See Kubota motor-manual.
Содержание Panda 6000i PMS
Страница 9: ...Panda 6000i PMS 230V 50Hz 6kW Fischer Panda GmbH Panda 6000i Part 1 Generator Manual ...
Страница 10: ...10 Current revision status Document Actual Panda 6000i generator_s01835_eng R01_16 1 09 Replace Revision Page ...
Страница 14: ...14 Socket wrench set Hexagon wrench keys ...
Страница 18: ...18 Intentionally Blank ...
Страница 91: ...Panda iControl Panel_iControl_eng fm Chapter A Panda iControl Page 91 A 9 2 Dimensions Fig A 9 2 1 Dimensions ...
Страница 92: ...Panda iControl Page 92 Chapter A Panda iControl Panel_iControl_eng fm Intentionally Blank ...
Страница 93: ...Panda_PMGi_6000_eng R0116 1 09 PMGi 6000 Fischer Panda GmbH Panda i series Part 3 PMGi 6000 inverter Manual ...
Страница 94: ...94 Current revision status Document Actual Panda_PMGi_6000_eng R01_16 1 09 Replace Revision Page ...
Страница 106: ...Panda PMGi 6000 Page 106 Chapter A Panda PMGi 6000 PGMi 6000_eng fm Fischer Panda Datasheet Intentionally Blank ...