Installation Instructions
Seite/Page 82 Panda_4000s_PMS_SCB_FCB_eng.R04 - Kapitel/Chapter 5: Installation Instructions
26.1.11
5.4.5.2 Position of the water collector
Important Note!
The ideal position of the water collector would be in center underneath the generator. Only in this position it
is assured that the water level can not change drastically in tilted position by the water collector moving out
of the center line. See the following pictures:
Fig. 5.4.5.2-1: Ideal position of the water collector
In this picture, the water collector is mounted in center underneath the gene-
rator. When the ship tilts, the position of the water collector related to the cri-
tical point at the exhaust duct changes only slightly.
Fig. 5.4.5.2-2: Tilted position 15 degrees
Tilted position 15 degrees
The distance from the exhaust elbow to the hydrostatic head derated to 540
mm.
Содержание 4000s PMS FC
Страница 24: ...Seite Page 22 General R01 1 26 1 11 Leere Seite Intentionally blank General References and Regulations...
Страница 68: ...Seite Page 66 Panda_4000s_PMS_SCB_FCB_eng R04 26 1 11 Leere Seite Intentionally blank The Panda Generator...
Страница 112: ...Seite Page 110 Panda_4000s_PMS_SCB_FCB_eng R04 26 1 11 Leere Seite Intentionally blank Maintenance Instructions...
Страница 122: ...Seite Page 120 Panda_4000s_PMS_SCB_FCB_eng R04 26 1 11 Leere Seite Intentionally blank Generator Failure...