- 28 -
BUILT-IN SENSOR DEFINITIONS
The following table gives a list of all the sensors whose definitions and support are
built into the data logger and so do not need to be explicitly defined in the program. A
more detailed description of the sensor tag names can be found in Appendix B.
Name
Tag Name
Units
String
Min
Value
Max
Value
Rain count
RnCnt
counts
0
65535
Logger clock source
ClkSrc
0
5
SDI voltage
SdiV
V
0.0
25.4
D cell pack voltage
D_Cell
V
0
25.4
Telemetry unit voltage
Telem
V
0.0
25.4
Current year
t_Year
1980
2115
Current month
t_Month
1
12
Current day of the month
t_Day
1
31
Current hour
t_Hour
0
23
Current minutes
t_Min
0
59
Current seconds
t_Sec
0
59
Current day of year
t_DayOfYr
1
366
Seconds since midnight
t_SeOfDy
0
86399
Seconds since start of hour
t_SeOfHr
0
3599
The logger clock source returns a value of 0 to 5 to indicate the clock status.
The values are as follows:
0: The battery backed clock has failed or is not present and the time in the
logger is likely to be incorrect.
1: The time was set by the user, either through the display or by telemetry.
2: The time was set from the battery backed clock.
3: The time has been set from a GPS clock (any GOES telemetry)
4: The time has been set from a high accuracy secondary clock in the G3
GOES telemetry unit.
5: The GPS clock has failed, and the logger was unable to use the G3
clock, so is using the logger crystal oscillator.
Содержание HDL1
Страница 1: ...HDL1 HDL1 G5 Data Logger Operating Manual...
Страница 2: ......
Страница 8: ...iv THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 12: ...4 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 20: ...12 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 42: ...34 THIS PAGE INTENTIONALLY LEFT BLANK...