background image

Pin 6 

Black/White 

- Auxiliary Input 2 – This wire functions as a negative (-) instant trigger input. It is 

selectable based on option 2-13. It can be changed to a negative disarm or negative drive lock 
control. Please refer to the option tables for details. This wire is required for ignition controlled 
door locks. 

 
Pin 7 

Yellow

 - Auxiliary 1 Output – This wire provides a customized timed output for triggering extra 

sensors and/or features such as power sliding doors or power windows. The settings can be 
changed via option 2-08. To set a custom timed output you must use option setting 4 as well as 
an OP500 Option Programmer. 

 
Pin 8   

Yellow/White

 - Auxiliary 2 Output – This wire provides a customized timed output for triggering 

extra sensors and/or features such as power sliding doors or power windows. The settings can be 
changed via option 2-09. To set a custom timed output you must use option setting 4 as well as 
an OP500 Option Programmer. 

 
 

Connector 4 (CN4), 4-Pin (Shock Sensor Port) 

 

Pin 1 

Black 

- Negative (-) ground. 

 
Pin 2 

White 

- 2

nd

 stage negative (-) input. (Instant trigger) 

 
Pin 3 

Red 

- 12V positive (+) output. 

 
Pin 4

  Yellow 

- 1

st

 stage negative (-) input. (Warn away) 

 

Connector 5 (CN5), 2-Pin (Pre-wired LED) 

 

Note:

 Do not mistake for Thermister port. 

 
 
 
Pin 1  

Black 

- L.E.D negative (-) ground.  

 
Pin 2  

Black/White

- L.E.D. 3V positive (+) output. 

 

Connector 6 (CN6), 4-Pin (Antenna Cable) 

 

 
 
 
 
Pin 1  

Yellow 

- RX input. This wire receives the signal from remote. 

 
Pin 2  

White 

- TX output. This wire transmits the signal to remote. 

 
Pin 3  

Red 

– Constant 12V positive (+) output. 

 
Pin 4

  Black 

– Negative (-) ground. 

 

10

 

Connector 7 (CN7), 4-Pin (RS232 Data Port) 

 

 
 
 
 
Pin 1   Constant 12V positive (+) output 
 
Pin 2   Negative (-) ground 
 
Pin 3   RX 
 
Pin 4  TX 

 

Option Programming Tables 

 

IMPORTANT: 

System must be unlocked before you can set options with the OP500 or remotes. 

 

  

Feature 

Default 

Setting- I 

Optional 

Setting - II 

Optional 

Setting - III 

Optional 

Setting - IV 

1-01 

Lock/Unlock Pulse 

Duration 

0.8 sec 

2.5 sec 

0.125 sec 

3.5 sec 

1-02 

Double Pulse Locks 

Off 

Unlock 

Lock 

Both 

1-03 

Driver’s Priority Unlock 

Off 

On 

  

  

1-04 

Ignition Locks* 

Ignition and 30 

Sec After 

Doors Closed

Drive Lock 

Control and 

Wire 

Off 

  

1-05 

Siren Duration 

30 Seconds 

60 Seconds 

120 Seconds 

Chirp for 20 

Seconds 

1-06 

Confirmation Chirps 

Length 

Medium 

(30ms) 

Short (15ms) 

Normal 

(60ms) 

  

1-07 

Auto Rearm 

Off 

30 Seconds 

60 Seconds 

5 Minutes 

1-08 

Passive Arming* 

Off 

On 

Passive 

Without Locks 

  

1-09 

Dome Light Delay 

Off 

5 Seconds 

45 Seconds 

Auto 

1-10 

Valet Mode 

Key 5 times, 

or Remote 

(I+III) while 

ignition is on 

Key 5 times or 

Remote (I+III)

  

  

1-11 

Open Door Notification 

On 

Off 

  

  

1-12 

Factory Alarm Option 

On 

Off 

  

  

1-13 

Siren/Horn Mute Control 

With Remote 

Disabled 

Enabled 

  

  

 
 
 
 

11

Содержание CM-2300

Страница 1: ...samente aprobados por la parte res p onsable del cum p limiento p ueden anular la autoridad del usuario p ara utilizar este dis p ositivo techfeed compustar com Installation Manual By Firstech LLC Version 1 0 Applicable to the following alarm system CM 2300 Alarm Keyless Control Module This device complies with Part 15 of the FCC rules Operation is subject to the following conditions 1 This device...

Страница 2: ...rchasing a Firstech alarm keyless system for your vehicle The following installation manual is intended for experienced and authorized mobile and alarm technicians This is not a tutorial on how to install We highly recommend that you contact your local Firstech dealer and seek professional installation Thank you for purchasing a Firstech alarm keyless system for your vehicle The following installa...

Страница 3: ...ow the instructions below IMPORTANT The remotes are preprogrammed to the control module In the event that you need to program the remotes follow the instructions below Programming the Remotes Programming the Remotes STEP 1 Activate Programming mode by turning the ignition key on and off between the Acc On positions five times within 7 seconds The vehicles parking lights will flash once with the su...

Страница 4: ...ds The parking lights will flash once to confirm the system is in valet mode Shortly after the first flash the parking lights will flash twice Jumper Settings Caution Jumper settings affect the polarity and use of certain outputs If these jumpers are used incorrectly damage to the vehicle and control module may occur Jumper 1 Door Trigger Polarity Determines the polarity of the door trigger input ...

Страница 5: ...egative output This is an optional output that will release the trunk System will unlock doors and disarm alarm prior to trunk release Pin 3 Orange Black 2nd Pulse Unlock wire This wire is used to provide the customer with a driver s priority unlock feature with option 1 04 With the option on the unlock blue wire will pulse first and then orange black will pulse if the unlock button is pressed aga...

Страница 6: ...mister port Pin 1 Black L E D negative ground Pin 2 Black White L E D 3V positive output Connector 6 CN6 4 Pin Antenna Cable Pin 1 Yellow RX input This wire receives the signal from remote Pin 2 White TX output This wire transmits the signal to remote Pin 3 Red Constant 12V positive output Pin 4 Black Negative ground 10 Connector 7 CN7 4 Pin RS232 Data Port Pin 1 Constant 12V positive output Pin 2...

Страница 7: ...ome vehicles This option can be changed to optional setting 2 by the remote Please see page 16 for details 1 03 Driver s Priority Unlock This lets you use the CM 2300 to unlock the driver s door before the rest of the doors as in some factory systems The user has the hit the unlock button on the remote a second time to unlock the rest of the doors The driver s door must be isolated from the other ...

Страница 8: ...by changing to optional setting 3 2 08 Aux 1 Output This option determines the duration of the Aux 1 output Setting 4 allows the output duration to be set for a specific length of time 2 09 Aux 2 Output This option determines the duration of the Aux 2 output Setting 4 allows the output duration to be set for a specific length of time 14 2 10 Aux 1 Output Control This option sets the condition whic...

Страница 9: ...onds Tap Key Button Wait for corresponding parking light flash and or siren chirp before selecting option Tap Lock Button Tap Unlock Button Hold Trunk Button for 3 seconds Tap Star Button 16 Option Menu 2 Lock Key for 3 seconds Tap Key Button Tap Lock Button Tap Unlock Button Hold Trunk Button for 3 seconds Tap Star Button How to Program Options With 1 Way 4 Button Remotes Wait for chirp between e...

Страница 10: ...ust have an Option Programmer OP500 to set a specific time output for the auxiliaries Please see the Option Tables in this manual for details The vehicle will lock and unlock but will not flash the parking lights or chirp the siren A The system is in valet mode Tap the Lock and Trunk Buttons and the same time for a half second to exit Valet Mode If that does not work try reprogramming the remotes ...

Страница 11: ...ebe utilizar dos relés SPDT para invertir la polaridad 20 Contactos de Soporte Técnico Soporte Tecnico de Firstech está reservado para los distribuidores autorizados Lunes a Viernes 888 820 3690 8 00 am 5 00 p m hora estándar del Pacífico Correo Electrónico support compustar com Web techfeed compustar com Web Diagramas de Cableado Ir a www firstechonline com Computech3 para acceder Si usted es un ...

Страница 12: ...rena A El sistema está en modo valet Toque en el bloqueo de enlaces y botones y al mismo tiempo por medio segundo para salir modo Valet Si eso no funciona pruebe la reprogramación los remotos 19 Opción de menú 2 Bloquear y Arranque durante 3 segundo s Toque botón medio segundo toque botón de bloqueo medio segundo toque botón de desbloque o Mantenga presionad o botón del maletero durante 3 segundos...

Страница 13: ...1 Activación instantánea con un negativo entrada Opción 2 Se desarmará la alarma con un negativo entrada Utilizado para agregar una alarma de fábrica sistema de entrada sin llave Opción 3 cambie el cable en un sensor de llave Si el cable disparador ve un negativo que no permiten que el sistema se arme Opción 4 Cambia el cable en un Bloqueo de la unidad de entrada Ctrl Si este cable disparador ve u...

Страница 14: ...le de ignición y sensor de impacto 2 13 Entrada Auxiliar 2 Esta opción cambia la condición de entrada del cable blanco negro en CN3 15 Valor de la Opción 2 se requiere el Ctrl Bloqueo de la unidad de entrada Aux 2 por favor consulte la opción 2 13 IV cable conexión Cuando se gire la llave de las puertas se desbloquearán si esta función está activada Esta característica también requiere la activaci...

Страница 15: ...nos de los sistemas El usuario tiene que oprimir una segunda vez para desbloquear el resto de las puertas La puerta del conductor debe estar aislado de las otras puertas Usar el color naranja negro CN3 como el 2o desbloquear 1 04 Contacto Cerradura de Mando Cuando se activa esta opción y se las cerraduras de puertas conectadas las puertas se cerrarán en 30 segundos cuando se arranca el vehículo co...

Страница 16: ...tivación instantánea Es seleccionable basado en la opción 2 13 Se puede cambiar a un negativo de desarmar o negativo de bloqueo Por favor consulte la table de opciones para obtener más información Este cable es necesario para la ignición controlada cerraduras de las puertas Pin 7 Amarillo Salida auxiliar 1 Este cable proporciona una salida personalizada para la activación temporizada sensores adic...

Страница 17: ... Blanco Entrada Auxiliar 1 Este cable funciona como un negativo antes de advertir de entrada Es seleccionable basado en la opción 2 12 Se puede cambiar a un negativo armar negativo negativo contacto con activación instantánea derivación del sensor shock negativo 9 Tabla de Cableria CM 2300 Hemos añadido las etiquetas de color en nuestro CM 2300 Por favor consulte la siguiente tabla de detalles Fun...

Страница 18: ...cendido on y luego off cinco veces dentro de 7 segundos Las luces de estacionamiento destellarán una vez para confirmar que el sistema está en modo valet Poco después del primer flash las luces de estacionamiento destellarán dos veces Configuración de los puentes Jumpers Precaución configuración de los puentes afectan a la polaridad y el uso de determinados productos Si estos puentes se utilizan i...

Страница 19: ...arcación rápida recomendado para la mayoría de los vehículos se encuentra en algún punto entre 2 y 4 El sistema comienza a monitorear el sensor de impacto 30 segundos después de que la alarma está armada También el LED de la alarma se mantendrá encendida después de armar hasta que el sensor de impacto está activo 5 Conceptos Básicos de Instalación Si usted es nuevo a instalar unidades de alarma Fi...

Страница 20: ...na Cableria 3 Tabla de Contenidos Introducción 3 Kit s Contenido 3 Conceptos Básicos de Instalación 4 Rutina de Código s del Remoto s 5 Colocación y uso de los componentes 5 Procedimientos comunes 6 Modo Valet 6 Configuración de los puentes Jumpers 6 Puente 1 activación de la polaridad de la puerta 6 Puente 2 Luz de estacionamiento Polaridad de salida 6 CM 2300 6 Diagrama de cableado de CM 2300 7 ...

Отзывы: