22
Fault Probable
Cause Solution
Water changes color
or becomes cloudy.
Fluid Rower is in direct
sunlight or has not had
water treatment.
Change Fluid Rower location to
reduce direct exposure to sun-
light. Add water treatment or
change tank water as directed
in the water treatment section of
this manual. Consider using dis-
tilled water to refill tank.
Fluid Rower belt slip-
ping off belt/ bungee
pulley.
Bungee not under
enough tension.
Tighten bungee cord following
the instructions in "Replacing
the Bungee/Shock Cord" sec-
tion of this manual.
Front of Fluid Rower
lifts slightly during vig-
orous rowing.
M10X150mm Vertical
Seat Rail Tensioning
Bolt is slightly too loose.
Tighten bolt 1/2 turn and row
again. Tighten as needed until
problem stops. Note: Over tight-
ening this bolt can damage the
seat rail. Only tighten bolt in
small increments until fault is
corrected.
The Fluid Rower com-
puter does not illumi-
nate after battery in-
stallation.
Batteries installed incor-
rectly or need replacing.
Reinstall batteries in correct po-
sition and try again. If the LCD
screen fails to illuminate, try ro-
tating the batteries slightly in the
computer. If this fails, contact
your local service center.
Fluid Rower Comput-
er screen illuminates,
but does not register
when rowing.
Loose or failed connec-
tion.
Check that the computer lead is
connected properly. If it is con-
nected then contact your local
service center.