• If you experience pain in muscles or joint for a
prolonged period of time, discontinue use and
consult your doctor. Persistent pain could be a
symptom of a more serious condition.
• Never use any massager on open wounds,
discoloured areas, or any area of the body
that is swollen, burned, inflamed or where skin
eruptions or sores are present.
• Massage should be pleasant and comfortable.
Should pain or discomfort result, discontinue
use and consult your physician.
SPECIAL WARNINGS:
• Never immerse foot massager in water or
other liquids.
• Always check the temperature of the water
before placing your feet into foot massager.
• Do not stand in the unit. Sit down and place
your feet in foot massager.
• Always unplug the unit when not in use and
when filling, emptying, cleaning or moving the
unit.
• Ensure that your hands dry when operating
the switch or removing the plug.
• Do not leave foot massager unattended while
it is operating.
INSTRUCTIONS FOR USE:
1. Ensure that the unit is unplugged before filling
with water.
Do not fill water over the fill line.
2. Select the feature using the dial control switch
• OFF
• VIBRATION/BUBBLE
• HEAT/INFRARED
• HEAT/INFRARED/VIBRATION/BUBBLE
3. Sit down and place your feet in the spa.
4. Enjoy a deep penetrating massage by sliding
feet back and forth over the reflex rollers.
5. To use the Pedicure Centre (only FA-8116-1)
a. Select desired attachment -
Attachment with pimples:
To smooth and
soften dry skin on heels and soles of feet
Brush:
Use to clean and exfoliate skin
Massage Balls:
Enjoy a relaxing massage
from your heels to the balls of your feet
b. Simply place the attachment on the centre
post.
c. Slide foot back and forth over the
attachment.
6. To empty: first unplug the unit. Tip the unit
allowing water to spill out along the drain
spout.
Never pour water over the control switch.
MAINTENANCE:
TO CLEAN:
Unplug the unit and allow it to cool before
cleaning. Clean only with a soft, damp cloth.
Never allow water or any other liquid to come into
contact with the control switch.
• After cleaning, wipe surfaces with a dry cloth.
• Never use abrasives, detergents or cleaning
agents.
• Periodically straighten cord if it becomes
twisted.
TO STORE:
Unplug the unit and allow it to cool.
• Store in its box or a clean, dry place.
• To avoid breakage, do not wrap the power
cord around the unit.
• Do not hang the unit by the power cord.
SPECIFICATIONS:
FA-8115-1: 220-240V • 50/60Hz • 450W
FA-8116-1: 230V • 50Hz • 450W
Correct Disposal of this product
You can help protect the environment! Please
remember to respect the local regulations: hand
in the non-working electrical equipments to an
appropriate waste disposal center..
3
ENGLISH
2
ENGLISH
INSTRUCTION MANUAL
FEATURES:
• Acupressure massage surface helps stimulate
the soles of your feet
• Heated floor to maintain warm water
temperature and relieve tired muscles
• Invigorating bubbles help relieve muscle
tension
• Rejuvenation massage to stimulate the soles
of your feet
• Pedicure centre with 3 custom attachments to
soften, smooth & exfoliate your feet
IMPORTANT SAFETY
INSTRUCTIONS:
When using an electrical appliance, basic
precautions should always be followed, including
the following:
READ ALL INSTRUCTIONS BEFORE USING
DANGER – to reduce the risk of electric
shock
• Always unplug the appliance from the
electrical outlet immediately after using and
before cleaning.
• DO NOT reach for an appliance that has fallen
into water. Unplug it immediately.
• DO NOT use while bathing or showering.
• DO NOT place or store appliance where it can
fall or be pulled into a tub or sink. DO NOT
place in or drop into water or other liquid.
• DO NOT attempt to plug or unplug unit while
feet in the water.
WARNING:
To reduce the risk of burns, fire, electric
shock or injury to persons:
• This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities,
or lack of experience and knowledge,
unless they have been given supervision or
instruction concerning use of the appliance by
a person responsible for their safety.
• Children should be supervised to ensure that
they do not play with the appliance.
• An appliance should never be left unattended
when plugged in. Unplug from outlet when not
in use before putting on or taking off parts or
attachments.
• Close supervision is necessary when this
appliance is used by, on, or near children,
invalids or disable persons.
• Use this appliance only for its intended use
as described in this manual. Do not use
attachments not recommended, specifically
any attachments not provided with this unit.
• Never operate this appliance with a damaged
cord or plug, if it is not working properly, if it
has been dropped or damaged, or dropped
into water. Return it to the service centre for
examination and repair.
• Keep cord away from hot surfaces.
• Never block the openings of the appliance,
or place it on a soft surface, such as a bed
or a couch, where the air openings may be
blocked. Keep air openings free of lint, hair,
dust etc.
• Never use while sleeping or fall asleep while
using the massager.
• Never drop or insert any object into any
opening.
• Do not operate where aerosol (spray)
products are being used or where oxygen is
being administered.
• Do not operated under blanket or pillow.
Excessive heating can occur and cause fire,
electrical shock or injury to persons.
• Do not carry this appliance by the supply cord
or use the cord as a handle.
• To disconnect, turn all controls to position
“OFF”, then remove the plug from outlet.
• Do not attempt to stand on or in foot
massager. Use only while seated.
• Use heated surface carefully. May cause
serious burns. Do not use over sensitive skin
areas or in the presence of poor circulation.
The unattended use of heat by children or
incapacated persons may be dangerous.
• Not use outdoors.
• Connect this appliance to a properly grounded
outlet only. See grounding instructions.
Caution:
All serving of this foot massager must be
performed by authorized service personal only.
SAVE THIS INSTRUCTIONS! FOR
HOUSEHOLD USE ONLY!
Caution – Please read all instructions
carefully before operating:
• If you have any concerns regarding your
health, consult your doctor before using foot
massager.
• Individuals with peacemakers should consult a
physician before using this product.
• In case of pregnancy, diabetes or illness,
consult your doctor before using.
• We recommended using this unit for no longer
than 20min at a time. Extensive use could
cause the product to overheat. Should this
occur, discontinue use and allow the unit to
cool before operating again.
Содержание FA-8115-1
Страница 16: ...30 31 OFF 20 1 2 3 4 FA 8116 1 5 6...