Page 25
English Customer Service: 1-844-FIRMAN1
A DC circuit protector has been provided to
protect the circuit from overloads. If an overload
occurs, the circuit protector will trip. The circuit
protector may be reset by pushing the button of
the protector.
DC CIRCUIT PROTECTOR
Charging a large capacity battery or a totally
discharged battery may cause the DC breaker to
turn off. In these cases, a separate battery charger
unit connected to an AC power source is
recommended instead of the DC receptacle on
the generator.
Stopping the Engine
1. Turn off and remove entire electrical loads.
Never start or stop the generator with
electrical devices plugged in or turned on.
Let the generator run at no-load for two minutes to stabilize
internal temperatures of the engine and generator.
2. Flip the engine switch to“
OFF
”(
O
) position.
Low Oil Shutdown
If the engine oil drops below a preset level, an
oil switch will stop the engine. Check oil level
with dipstick.
If oil level is between the
LOW
and
HIGH
mark on
dipstick:
1.Add oil to bring level to
HIGH
mark.
2.Restart engine and if the engine stops again
a low oil condition may still exist. DO NOT try
to restart the engine.
3.Contact an Authorized FIRMAN Service Dealer.
4.DO NOT operate engine until oil level is
corrected.
Do Not Overload Generator
Overloading a generator in excess of its rated
wattage capacity can result in damage to the
generator and to connected electrical devices.
To prolong the life of your generator and
attached devices, follow these steps to add
electrical load:
1.DO NOT try to restart the engine.
2.Contact an Authorized FIRMAN Service Dealer.
3.DO NOT operate engine until oil level is corrected.
If oil level is below the
LOW
mark on dipstick:
DO NOT stop engine by moving choke control
to “
START
” position.
Important
: Always ensure that the
is in the “
OFF
” position when the engine
is not in use.
fuel selector
switch
explosion resulting in death, serious injury
and/or property damage.
If the engine will not be used for a period of two
weeks or longer, please see the Storage section
for proper engine and fuel storage.
3. Turn the fuel selector switch to “
” position
(1:30 o’clock). The gasoline valve is close on this
position.
LPG
4. Fully close the LPG cylinder knob.
If a cover is used, do not install until unit has cooled.
WARNING
Fuel and its vapors are extremely flammable and
explosive which could cause burns, fire or
NOTE
:
Disconnect
the
LPG
cylinder from the
generator during transportation.
Содержание WH03041
Страница 4: ...SAFETY PRECAUTIONS Page 02 WARNING POISONOUS GAS HAZARD English Customer Service 1 844 FIRMAN1...
Страница 34: ...Page 34 PARTS DIAGRAM AND PARTS LIST WH03041 Parts Diagram English Customer Service 1 844 FIRMAN1...
Страница 35: ...Page 35 171cc Engine Parts Diagram English Customer Service 1 844 FIRMAN1...
Страница 77: ...33 Spanish Servicio al Cliente 1 844 FIRMAN1 171cc Motor Diagrama De Las Piezas...
Страница 118: ...LE SCHEMA DES PIECES ET LA LISTE DE PIECES 32 WH03041 LE SCHEMA DES PIECES Fran ais Service Clients 1 844 FIRMAN1...
Страница 119: ...33 Fran ais Service Clients 1 844 FIRMAN1 171cc Moteur Sch ma Des Pi ces...