How to Install Your Smoke Alarm

This smoke alarm is shipped with the battery disconnected. You
MUST properly connect the battery before mounting the smoke
alarm to the wall or ceiling. The smoke alarm will not operate 
without the battery first being properly connected.

Read SMOKE ALARM PLACEMENT information on page 3. After you
have selected the locations for the installation of smoke alarms:

1. Unlock and remove mounting plate by turning it counter-clock-

wise. (For tamper-resist option, twist out and set aside the locking
pin molded into the battery compartment of the plastic smoke
alarm base.)

2. Place mounting bracket against ceiling or wall where you wish to

mount the smoke alarm. Use a pencil to trace the inside of the
two mounting hole locations.

3. Drill two holes, using a 3/16 in. (5 mm) drill bit in the centers 

of the hole locations and insert anchors into holes.

4. Use mounting screws to secure mounting bracket to ceiling 

or wall.

5. Connect new 9-volt battery to battery connector inside battery

pocket. BE SURE BATTERY IS SECURELY CONNECTED. Smoke
alarm may beep briefly when battery is installed. Firmly depress
the test button for ten (10) seconds. The smoke alarm should
sound its alarm horn, indicating the battery is connected properly.
The Quick-Quiet™ Alarm Control feature will activate for a 
maximum of 15 minutes after testing.

6. Insert battery into battery pocket.
7. For tamper resist, use long-nosed pliers to remove thin plastic

from notch on smoke alarm edge.

8. Position smoke alarm to mounting bracket and turn clockwise.

The smoke alarm will lock into place. (To engage tamper-resist
feature, insert pin into notch on edge of smoke alarm and 
mounting plate.)

NOTE: Smoke alarm will not mount to bracket if battery 

is not installed.

9 Test smoke alarm. See TESTING your SMOKE ALARM.

DO NOT connect this smoke alarm to any other detector or
electrical device. Doing so will cause the smoke alarm to 
operate improperly or fail to operate.

Testing Your Smoke Alarm

If alarm horn sounds, and smoke alarm is not being tested,
the smoke alarm is sensing smoke. THE SOUND OF THE
ALARM HORN REQUIRES YOUR IMMEDIATE ATTENTION 
AND ACTION.

Test each smoke alarm weekly to be sure it is installed correctly and
operating properly.
Test smoke alarms upon returning from vacation. Also test when no
one has been in the household for several days.
Stand at arm’s length from the smoke alarm when testing. The large
test button is shaped so that the end of a broomstick can be used to
test. The alarm horn is loud to alert you to an emergency. The alarm
horn may be harmful to your hearing.

The center test button accurately tests all functions. NEVER use an
open flame from a match or lighter to test this smoke alarm. You may
ignite and set fire to the smoke alarm and your home.
Test all smoke alarms weekly as follows:
1. Look at the LED power indicator. A visual light flashing about once

a minute indicates the smoke alarm is receiving battery power.
See “LED Power/Alarm Indicator” chart.

4

Insert pin here

WARNING

!

Remove thin plastic from notch

WARNING

!

Insert pin here

Содержание CCPB

Страница 1: ...e information it contains the easier you will find it to install operate and maintain your smoke alarm properly which ultimately means greater security and peace of mind for you and your family Invensys Controls The ionization type alarms are generally more effective at detecting fast flaming fires which consume combustible materials rapidly and spread quickly Sources of these fires may include fl...

Страница 2: ...er and about 0 1 m 4 in down the wall as shown in Figure A 11 8 3 Detectors should not be placed in this dead air space Smoke and heat detectors should be installed in those loca tions recommended by the manufacturer s published instructions except in those cases where the space above the ceiling is open to the outside and little or no insulation is present over the ceiling Such cases result in th...

Страница 3: ...s between 4 and 12 inches from ceiling wall intersections Install a smoke alarm in each room that is divided by a partial wall either coming down from the ceiling at least 24 inches or coming up from the floor Install smoke alarms on peaked cathedral or gabled ceilings at or within 3 feet from the highest point measured horizontally Install a smoke alarm in lived in attics or attics which house el...

Страница 4: ...move thin plastic from notch on smoke alarm edge 8 Position smoke alarm to mounting bracket and turn clockwise The smoke alarm will lock into place To engage tamper resist feature insert pin into notch on edge of smoke alarm and mounting plate NOTE Smoke alarm will not mount to bracket if battery is not installed 9 Test smoke alarm See TESTING your SMOKE ALARM DO NOT connect this smoke alarm to an...

Страница 5: ...racell MN 1604 and long life lithium battery Ultralife U9VL J DO NOT USE ANY OTHER TYPE OF BATTERY EXCEPT AS SPECI FIED IN THIS MANUAL DO NOT USE RECHARGEABLE BATTERIES 1 Turn smoke alarm counter clockwise to detach from mounting plate 2 Remove battery from pocket Disconnect and discard drained battery from battery connector 3 Connect a fresh 9 volt or 9 volt lithium battery to connector The batte...

Страница 6: ...ng smoke alarms that work from two different power sources can give extra protection in case of a dead battery or an AC power failure If you have repeated false alarms move the smoke alarm to a different location This smoke alarm is designed to be used inside a single family household In multi family buildings each individual living unit should have its own alarms It is not a substitute for a comp...

Страница 7: ...ollow predefined escape plans if possible 3 Meet at a pre arranged meeting place outside the building 4 Call the fire department from OUTSIDE the building 5 DO NOT GO BACK INSIDE A BURNING BUILDING Wait for the fire department to arrive These guidelines will assist you in the event of a fire However to reduce the chance that fires will start practice fire safety rules and prevent hazardous situati...

Страница 8: ...TE Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you IN NO CASE SHALL INVENSYS CONTROLS BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED WHATSOEVER EVEN IF THE LOSS OR DAM AGE IS CAUSED BY ITS NEGLIGENCE OR FAULT Some states do not allow the exclusion or limitatio...