Force Table (Use for Airstroke
®
actuator design)
Volume
Pounds Force
Assembly @ 100
Height
PSIG
@20
@40
@60
@80
@100
(in.)
(in
3
)
PSIG
PSIG
PSIG
PSIG
PSIG
13.0
110
130
280
440
580
740
12.0
102
130
280
450
600
760
11.0
94
140
280
450
600
760
10.0
85
150
290
450
600
770
9.0
77
150
290
450
600
770
8.0
69
170
310
460
610
760
7.0
60
270
420
580
750
920
Dynamic Characteristics at 10.5 in. Design Height
(Required for Airmount isolator design only)
Volume @ 100 PSIG = 89 in
3
Gage
Spring
Pressure
Load
Rate
(PSIG)
(lbs.)
(lbs./ in.)
40
290
53
81
1.35
60
450
75
77
1.28
80
600
91
73
1.22
100
770
114
72
1.21
Description
Assembly Order No.
Blind nuts, 1/4 NPT
WO1-358-8119
Socket head aluminum bead
ring (bolts, nuts, washers not
included, use cap screws)
WO1-358-8118
Assembly weight ........................................................ 3.5 lbs.
Natural
Frequency
CPM
HZ
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
9 8 7 6
MAX. HT.
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
15 14 13 12 11 10
MIN. HT.
60 Psig
20 Psig
100 Psig
80 Psig
40 Psig
120 Psig
Do not use Airstroke in
shaded area without
consulting Firestone
Volume
100 Psig
CONSULT FIRESTONE
BEFORE USING AS
AIRMOUNT
RECOMMENDED
AIRMOUNT
DESIGN HEIGHT
10.5 INCHES
Static Data
9232
HEIGHT IN.
HEIGHT
4.75
5.0 MAX O.D.
AT 100 PSIG
15-20 IN. LBS.
TORQUE
1/2-13 THREADED HOLE
(1.00 DEEP)
4.50 DIA.
1/4 NPT
AIR INLET
4.37 DIA.
3/8-16 BLIND NUTS
(5/8 DEEP)
25-30 IN. LBS.
TORQUE
1.75
NOTE: Bellows will not compress properly with less
than 10 PSIG internal pressure.
NOTE: A bead plate part is shown. This part is also
available with a bead ring. Bolts are not included.
See pages 8-10 for explanation.
See page 12 for instructions on how to use chart.
V
OLUME (WITHOUT B
UMPER) CU IN. x 10
FORCE LBS x 100
Style
1T12E-3
Two
Ply
Bellows
85
1T12E-3