Force Table (Use for Airstroke
®
actuator design)
Volume
Pounds Force
Assembly @ 100
Height
PSIG
@20
@40
@60
@80
@100
(in.)
(in
3
)
PSIG
PSIG
PSIG
PSIG
PSIG
3.0
32
220
420
640
880
1,120
2.0
17
350
680
1,020 1,370 1,720
Dynamic Characteristics at 3.0 in. Design Height
(Required for Airmount isolator design only)
Volume @ 100 PSIG = 32 in
3
Gage
Spring
Pressure
Load
Rate
(PSIG)
(lbs.)
(lbs./ in.)
40
420
765
254
4.24
60
640
1,088
244
4.07
80
880
1,410
237
3.96
100
1,120
1,710
232
3.86
Description
Assembly Order No.
Blind nuts, 1/4 NPT
WO1-358-7001
Blind nuts, 3/4 NPT
WO1-358-6996
Socket head aluminum bead
rings (bolts, nuts, washers not
included-use 1/4 cap screws)
WO1-358-0017
3/4 NPT (only) upper plate,
blind nuts lower plate
WO1-358-0286
Rubber bellows only
WO1-358-0010
Assembly weight ........................................................ 2.5 lbs.
Force to collapse to minimum height (@ 0 PSIG)....... 30 lbs.
Natural
Frequency
CPM
HZ
MAX. HT.
MIN. HT.
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
20 Psig
40 Psig
60 Psig
80 Psig
100 Psig
120 Psig
3.5 3.0 2.5
1.9
Volume
100 Psig
4
3
2
1
Do not use Airstroke in
shaded area without
consulting Firestone
RECOMMENDED
AIRMOUNT
DESIGN HEIGHT
3.0 INCHES
Static Data
7559
HEIGHT IN.
16
38
6.0 MAX O.D.
AT 100 PSIG
HEIGHT
4.50 DIA.
3/8-16 BLIND NUTS
(5/8 DEEP)
1.75
1/4 NPT
AIR INLET
15-20 FT. LBS.
TORQUE
NOTE: A bead plate part is shown. This part is
also available with bead rings. Bolts are not included.
See pages 8-10 for explanation.
See page 12 for instructions on how to use chart.
V
OLUME (WITHOUT B
UMPER) CU IN. x 10
FORCE LBS x 100
Style
16
Two
Ply