117
FIREROCK
INSTALLATION
STEP THREE: THROAT
A piece of angled steel (2” x 2” x 1/4” thick) has been provided with your FireRock fireplace kit (30” - 48” only). The
length of this angled steel piece corresponds with the overall width of your firebox model. It should be installed across
the top of the firebox opening - angle up for maximum firebox opening, or angle down for additional “smoke lip.” For
60” and 72”, the angle iron (6” x 6” x 1/2” thick) must be purchased separately.
Begin building the throat by placing the angle iron in the desired position. Next, place the radius throat on top of the
angle iron and place the square throat back at the back of the firebox. Given the curvature of our lintel to aid in smoke
draw, you’ll want to keep a hand on this piece while placing the throat left and throat right pieces to secure it in place.
STEP 4: SETTING THE DAMPER
Upon setting the 4 throat components, a recess is formed for the purpose of locating the damper.
Each fireplace uses a different size damper.
30” firebox - 24” damper
36” firebox - 30” damper
42” firebox - 36” damper
48” firebox - 42” damper
STEP 5: SMOKE CHAMBER
The smoke chamber components can only be positioned one way. The fronts and backs are identical above the damper.
Be sure to check for and maintain plumb and level installation of these components. “Butter” all joints to give a smooth
appearance and ensure a leak-free joint.
Содержание 3620 Avenue C
Страница 19: ...19 FIREPLACE DIMENSIONS Correlate the framing dimensions on the previous page with the diagram above...
Страница 20: ......
Страница 21: ...21 PRODUCT PAGES...
Страница 29: ...29 FireRock Specifications Approved for Indoor Outdoor Use 48 Conventional FR0048...
Страница 35: ...35 FireRock Specifications 30 Rumford FR0530 Approved for Indoor Outdoor Use...
Страница 37: ...37 FireRock Specifications Approved for Indoor Outdoor Use 36 Rumford FR0536...
Страница 39: ...39 FireRock Specifications Approved for Indoor Outdoor Use 42 Rumford FR0542...
Страница 41: ...41 FireRock Specifications Approved for Indoor Outdoor Use 48 Rumford FR0548...
Страница 51: ...51 FireRock Specifications Approved for Indoor Outdoor Use 30 Vent Free FR0230...
Страница 53: ...53 FireRock Specifications Approved for Indoor Outdoor Use 36 Vent Free FR0236...
Страница 55: ...55 FireRock Specifications Approved for Indoor Outdoor Use 42 Vent Free FR0242...
Страница 57: ...57 FireRock Specifications Approved for Indoor Outdoor Use 48 Vent Free FR0248...
Страница 59: ...59 FireRock Specifications Approved for Indoor Outdoor Use 30 Vent Free Lite FR0630...
Страница 61: ...61 FireRock Specifications Approved for Indoor Outdoor Use 36 Vent Free Lite FR0636...
Страница 63: ...63 FireRock Specifications Approved for Indoor Outdoor Use 42 Vent Free Lite FR0642...
Страница 65: ...65 FireRock Specifications Approved for Indoor Outdoor Use 48 Vent Free Lite FR0648...
Страница 67: ...67 FireRock Specifications Approved for Outdoor Use Only 30 Outdoor Conventional FR0730...
Страница 69: ...69 FireRock Specifications Approved for Outdoor Use Only 36 Outdoor Conventional FR0736...
Страница 73: ...73 FireRock Specifications Approved for Outdoor Use Only 30 Arched Outdoor Conventional FR1230...
Страница 75: ...75 FireRock Specifications Approved for Outdoor Use Only 36 Arched Outdoor Conventional FR1236...
Страница 77: ...77 FireRock Specifications Approved for Outdoor Use Only 42 Arched Outdoor Conventional FR1242...
Страница 83: ...83 FireRock Specifications Approved for Outdoor Use Only FireRing FRRING...
Страница 85: ...85 FireRock Specifications Approved for Outdoor Use Only Square Fire Pit FRSQ60...
Страница 90: ...90 DURACHIMNEY II AIR COOLED CHIMNEY FOR MASONRY FIREPLACES UL 103...
Страница 102: ...102 DuraChimney ii Installation Instructions Air Cooled All Fuel Chimney for Masonry Fireplaces...
Страница 123: ......
Страница 124: ......