![Firepower MST 220i Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/firepower/mst-220i/mst-220i_operating-manual_2292060052.webp)
FIREPOWER MST 220i
INSTALLATION/SETUP
3-22
Manual 0-5343
3.18 Wire Reel Brake
The wire reel hub incorporates a friction brake which is adjusted during manufacture for optimum braking.
If it is considered necessary, adjustment can be made by turning the Thumb Screw inside the open end of the
hub clockwise to tighten the brake. Correct adjustment will result in the wire reel circumference continuing no
further than 1/8"-3/16" (3-5mm) after release of the trigger. The electrode wire should be slack without becoming
dislodged from wire spool.
CAUTION
Overtension of brake will cause rapid wear of mechanical WIREFEED parts, overheating of electrical
componentry and possibly an increased incidence of electrode wire Burnback into contact tip.
Spool Hub Tension
Thumb Screw
Art # A-12534
Figure 3-18: Wire Reel Brake
3.19 Setup For MIG (GMAW) Welding With Gas Shielded MIG Wire
A. Select MIG mode with the process selection control. (Refer to Section 3.10 for further information)
B. Connect the MIG polarity lead to the positive welding terminal (+). If in doubt, consult the electrode wire manu-
facturer. Welding current flows from the Power Source via dinse type terminals. It is essential, however, that
the male plug is inserted and turned securely to achieve a sound electrical connection.
C. Fit the MIG gun to the power source. (Refer to section 3.11 Attaching the Firepower Fusion 220A MIG Gun).
D. Connect the work lead to the negative welding terminal (-). If in doubt, consult the electrode wire manufacturer.
Welding current flows from the Power Source via dinse type terminals. It is essential, however, that the male
plug is inserted and turned securely to achieve a sound electrical connection.
E. Fit the welding grade shielding gas regulator/flowmeter to the shielding gas cylinder (refer to Section 3.06)
then connect the shielding gas hose from the rear of the power source to the regulator/flowmeter outlet.
F. Refer to the Weld Guide located on the inside of the wirefeed compartment door for further information.
G. Switch the LOCAL/REMOTE switch inside the
wire feed compartment to LOCAL to use the
Power Sources Wirespeed and Voltage controls.
H. Switch the MIG GUN/SPOOL GUN switch inside
the wire feed compartment to MIG GUN.
Содержание MST 220i
Страница 6: ...This Page Intentionally Blank...
Страница 24: ...FIREPOWER MST 220i SAFETY INSTRUCTIONS AND WARNINGS 1 18 Manual 0 5343 This Page Intentionally Blank...
Страница 80: ...FIREPOWER MST 220i BASIC WELDING 4 22 Manual 0 5343 This Page Intentionally Blank...
Страница 90: ...FIREPOWER MST 220i REPLACEMENT PARTS 6 4 Manual 0 5343 This Page Intentionally Blank...
Страница 92: ...FIREPOWER MST 220i APPENDIX A 2 Manual 0 5343 This page intentionally blank...
Страница 94: ...This page intentionally blank...