Firepower MST 140i
INSTALLATION, OPERATION AND SETUP
3-24
Manual 0-5338
3.21 Setup for LIFT TIG (GTAW) Welding
A. Select LIFT TIG mode with the process selection control (refer to Section 3.10.12 for further information).
B. Using the supplied 50mm to 25mm DINSE adapter, connect the TIG torch to the negative welding terminal (-). Welding
current flows from the Power Source via Dinse style connectors. It is essential, however, that the male plug is inserted
and turned securely to achieve a sound electrical connection.
C. Connect the work lead to the positive welding terminal (+). Welding current flows from the Power Source via Dinse
style terminals. It is essential, however, that the male plug is inserted and turned securely to achieve a sound electrical
connection.
D. Connect the TIG torch trigger switch via the 8 pin socket located on the front of the Power Source. The TIG torch will
require a trigger switch to weld in LIFT TIG Mode.
NOTE
A Firepower 17V TIG torch with an 8 pin plug must be used to turn the weld current on/off via the TIG torch trigger
switch to TIG weld OR a Firepower Foot Control with an 8 pin plug must be used to turn the weld current on/off
as well as providing remote control of the weld current. Please refer to "2.10 Options and Accessories".
E. Fit the flowmeter/ regulator to the shielding gas cylinder (refer to Section 3.06) then connect the shielding gas hose from
the TIG torch to the flowmeter/ regulator outlet. Note that the TIG torch shielding gas hose is connected directly to the
flowmeter/ regulator. The Power Source is not fitted with a shielding gas solenoid to control the gas flow in LIFT TIG mode
therefore the TIG torch will require a gas valve.
!
WARNING
Before connecting the work clamp to the work piece, make sure you have ceased feeding wire so premature arcing
will not occur.
Secure the shielding gas cylinder in an upright position by chaining it to a stationary support to prevent falling
or tipping.
CAUTION
Remove any packaging material prior to use. Do not block the air vents at the front or rear of the Welding Power
Source.
Loose welding terminal connections can cause overheating and result in the male plug being fused in the terminal.
F. Switch the LOCAL/REMOTE switch inside the wire feed compartment to LOCAL to use the Power Sources Amperage
control or REMOTE for remote amperage using a Foot Control.
Содержание MST 140i
Страница 6: ...This Page Intentionally Blank ...
Страница 76: ...Firepower MST 140i BASIC WELDING GUIDE 4 24 Manual 0 5338 This Page Intentionally Blank ...
Страница 82: ...Firepower MST 140i KEY SPARE PARTS 6 2 Manual 0 5338 6 02 Power Source Art A 12518 31 ...
Страница 86: ...Firepower MST 140i KEY SPARE PARTS 6 6 Manual 0 5338 This Page Intentionally Blank ...
Страница 87: ...Firepower MST 140i Manual 0 5338 1 APPENDIX APPENDIX This Page Intentionally Blank ...
Страница 88: ...Firepower MST 140i APPENDIX 2 Manual 0 5338 8 I Art A 12517 APPENDIX Firepower MST 140i CIRCUIT DIAGRAM ...
Страница 89: ...Firepower MST 140i Manual 0 5338 3 APPENDIX Art A 12517 ...