background image

GENERAL INFORMATION

8

Date 5/1/00 (Special)

1.08  Statement of Warranty

LIMITED WARRANTY:

  Firepower® (hereinafter “Firepower”) warrants that its products will be free of defects in workmanship or

material.  Should any failure to conform to this warranty appear within the time period applicable to the Firepower products as stated
below, Firepower shall, upon notification thereof and substantiation that the product has been stored, installed, operated, and maintained
in accordance with Firepower’s specifications, instructions, recommendations and recognized standard industry practice, and not subject
to misuse, repair, neglect, alteration, or accident, correct such defects by suitable repair or replacement, at Firepower’s sole option, of
any components or parts of the product determined by Firepower to be defective.

THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE.

LIMITATION OF LIABILITY:

  Firepower shall not under any circumstances be liable for special or consequential damages, such as, but

not limited to, damage or loss of purchased or replacement goods, or claims of customers of distributor (hereinafter “Purchaser”) for
service interruption.  The remedies of the Purchaser set forth herein are exclusive and the liability of Firepower with respect to any
contract, or anything done in connection therewith such as the performance or breach thereof, or from the manufacture, sale, delivery,
resale, or use of any goods covered by or furnished by Firepower whether arising out of contract, negligence, strict tort, or under any
warranty, or otherwise, shall not, except as expressly provided herein, exceed the price of the goods upon which such liability is based.

THIS WARRANTY BECOMES INVALID IF REPLACEMENT PARTS OR ACCESSORIES ARE USED WHICH MAY IMPAIR THE
SAFETY OR PERFORMANCE OF ANY FIREPOWER PRODUCT.

THIS WARRANTY IS INVALID IF THE PRODUCT IS SOLD BY NON-AUTHORIZED PERSONS.

The limited warranty periods for Firepower products shall be as follows:  A maximum of three (3) years from date of sale to an authorized
distributor and a maximum of two (2) years from date of sale by such distributor to the Purchaser, and with the following further
limitations on such two (2) year period.

PARTS

FP-80, POWER SUPPLIES

All OTHERS

LABOR

MAIN POWER MAGNETICS ...................................................................................................... 2 YEARS ................... 1 YEAR

ORIGINAL MAIN POWER RECTIFIER ..................................................................................... 2 YEARS ................... 1 YEAR

CONTROL PC BOARD .................................................................................................................. 2 YEARS ................... 1 YEAR

ALL OTHER CIRCUITS AND COMPONENTS ......................................................................... 1 YEAR .................... 1 YEAR

INCLUDING, BUT NOT LIMITED TO, STARTING
CIRCUIT, CONTACTORS, RELAYS, SOLENOIDS, PUMPS,
POWER SWITCHING SEMI-CONDUCTORS

CONSOLES, CONTROL EQUIPMENT, HEAT

............................................................................. 1 YEAR .................. 1 YEAR

EXCHANGES, AND ACCESSORY EQUIPMENT

TORCH AND LEADS

......................................................................................................................... 1 YEAR .................. 1 YEAR

REPAIR/REPLACEMENT PARTS

.................................................................................................... 90 DAYS .................. NONE

Warranty repairs or replacement claims under this limited warranty must be submitted by an authorized Firepower repair facility
within thirty (30) days of the repair.  No transportation costs of any kind will be paid under this warranty.  Transportation charges to
send products to an authorized warranty repair facility shall be the responsibility of the customer.  All returned goods shall be at the
customer’s risk and expense.  This warranty supersedes all previous Firepower warranties.

Effective  May 5, 2000

Содержание FP-80

Страница 1: ...Manual No 0 2803 November 7 2001 Plasma Cutting Power Supply Model FP 80 Operating Manual A 02218...

Страница 2: ......

Страница 3: ...2803 Published by Thermal Dynamics Corporation Industrial Park No 2 West Lebanon New Hampshire USA 03784 603 298 5711 Copyright 2000 by Thermal Dynamics Corporation All rights reserved Reproduction of...

Страница 4: ...CTION 3 INSTALLATION PROCEDURES 11 3 01 Introduction 11 3 02 Site Selection 11 3 03 Unpacking 11 3 04 Lifting Options 11 3 05 Input Power Connections 12 3 06 Input Voltage Selection 13 3 07 Input Powe...

Страница 5: ...tion 29 6 02 Ordering Information 29 6 03 Complete Power Supply Replacement 30 6 04 Basic Parts Replacement 30 6 05 Options and Accessories 30 APPENDIX I INPUT WIRING REQUIREMENTS 31 APPENDIX II SEQUE...

Страница 6: ......

Страница 7: ...your head out of the welding fume plume Use an air supplied respirator if ventilation is not adequate to remove all fumes and gases The kinds of fumes and gases from the plasma arc depend on the kind...

Страница 8: ...s in this manual PLASMAARC RAYS PlasmaArc Rays can injure your eyes and burn your skin The plasma arc process produces very bright ultra violet and infra red light These arc rays will damage your eyes...

Страница 9: ...le from American National Standards Institute 1430 Broadway New York NY 10018 1 04 Note Attention et Avertissement Dans ce manuel les mots note attention et avertissement sont utilis s pour mettre en...

Страница 10: ...l nergie lectrique haute tension Cette nergie lectrique peut produire des chocs graves voire mortels pour l op rateur et les autres personnes sur le lieu de travail Ne touchez jamais une pi ce sous te...

Страница 11: ...visions les plus r centes ayant t faites celles ci pour de plus amples renseignements 1 OSHA NORMES DE S CURIT DU TRAVAIL ET DE PROTECTION DE LA SANT 29CFR 1910 disponible aupr s du Superintendent of...

Страница 12: ...da M9W 1R3 13 ivret NWSA BIBLIOGRAPHIE SUR LA S CURIT DU SOUDAGE disponible aupr s de l Association Nationale de Fournitures de Soudage National Welding Supply Association 1900 Arch Street Philadelphi...

Страница 13: ...ion standard C22 2 number 60 forArc welding equipment UL Underwriters Laboratory rating 94VO flammability testing for all printed circuit boards used ISO IEC 60974 1 BS 638 PT10 EN 60 974 1 EN50192 EN...

Страница 14: ...power whether arising out of contract negligence strict tort or under any warranty or otherwise shall not except as expressly provided herein exceed the price of the goods upon which such liability is...

Страница 15: ...e power supply is designed to work with the Model PCH 102 Plasma Torches The torch includes a spare parts kit which provides an assortment of replacement torch parts NOTE Refer to Section 2 04 for lis...

Страница 16: ...ing information A Two Stage Air Line Filter An optional two stage air line filter is available The filter will remove moisture and contaminants from the air stream when using compressed air The filter...

Страница 17: ...t least 2 feet 0 61 m in the rear and at least 6 inches 0 15 m on each side for clearance Pro vide sufficient clearance in front of the unit to allow ac cess to the front panel controls minimum 6 inch...

Страница 18: ...nd national elec tric codes Recommended circuit protection and wiring requirements are shown in Appendix I C Opening Power Supply Enclosure The Cover of the Power Supply must be removed to gain access...

Страница 19: ...oltage Selection 3 07 Input Power Cable Connections The primary power cable must be supplied see Note by the end user and installed to the Power Supply assembly Recommended cable sizes are specified i...

Страница 20: ...te the ground stud and remove the top nut and washer d Install a lug terminal on the ground wire e Place the ground wire onto the ground stud and secure with the nut and washer f Insert the other two...

Страница 21: ...the barb fitting 4 Place an adjustable hose clamp over the gas supply hose Regulator Filter Assembly 1 4 NPT to 4 6mm Hose Fitting 4 6mm Gas Supply Hose Hose Clamp A 00916 Figure 3 8 Gas Connection To...

Страница 22: ...Plasma Lead Adapter Connector Pilot Lead Stud Negative Plasma Lead Connection A 02825 Control PIP Circuit Connectors Figure 3 11 Torch Lead Connections 6 Connect the PIP Cables to the mating connector...

Страница 23: ...3 m from any CNC components drive motors control cables or primary power lines 4 Keep torch leads clean Dirt and metal particles bleed off energy which causes difficult starting and in creased chance...

Страница 24: ...INSTALLATION PROCEDURES 18 Manual 0 2803...

Страница 25: ...eads boot and hole in the front panel to allow feeding the torch leads through to an internal bulk head for connecting the torch leads 3 Work Cable and Clamp Work cable with clamp factory Installed 4...

Страница 26: ...behind the Front Panel and requires removal of the Power Supply Cover for access 1 Negative Plasma Lead Connection Connects the torch negative plasma lead to the unit 1 2 3 A 02230 Figure 4 3 Torch P...

Страница 27: ...ON if the gas pres sure is set below 45 psi 3 1 bar at the Regulator Filter Assembly 5 Place RUN SET switch to RUN mode a Gas flow stops b GAS indicator turns OFF 6 Protect eyes and press or activate...

Страница 28: ...tion Select desired gas air or nitrogen Make sure gas source meets pressure and flow requirements refer to Section 3 08 Gas Connections Check connection and turn gas supply on D Work Cable Connection...

Страница 29: ...r torch leads Frequently review the Important Safety Precau tions page 1 Be sure the operator is equipped with proper gloves clothing eye and ear protection Make sure no part of the operator s body co...

Страница 30: ...utting current too low 2 Main Arc Extinguishes a Cutting speed too slow b Torch standoff too high from workpiece c Cutting current too high d Work cable disconnected e Worn torch parts 3 Excessive Dro...

Страница 31: ...ted a Check for obstructed air flow and correct con dition 2 Fan blocked a Check and correct condition 3 Unit is overheated a Allow unit to cool down for about 5 minutes Make sure the unit has not bee...

Страница 32: ...as not connected or pressure too low a Check source for at least 60 psi 4 1 bar 2 Faulty components in unit a Return for repair or have qualified technician repair per Service Manual I Torch cuts but...

Страница 33: ...the inside of the unit 4 To reinstall the Cover reverse the above procedure B Fuse Replacement 1 Remove the Cover per paragraph A above 2 Locate the internal fuse above the Input Power PC Board on th...

Страница 34: ...SERVICE 28 Manual 0 2803...

Страница 35: ...Parts listed without item numbers are not shown but may be ordered by the catalog number shown B Returns If a product must be returned for service contact your authorized distributor Materials returne...

Страница 36: ...208 230VAC Single Phase With Input Power Cable Plug 1 1445 0002 6 04 Basic Parts Replacement Qty Description Catalog 1 230V Single Phase Input Power Cable 9 8599 1 Fuse 0 8A 600V 9 7526 1 Knob Curren...

Страница 37: ...it P rotection and W ire S iz es B ased on National E lectric Code and Canadian E lectric al Code NOTES Refer to Local and National Codes or local authority having jurisdiction for proper wiring requi...

Страница 38: ...orch is within transfer distance 3 8 in of workpiece main arc will transfer After post flow Gas solenoid closes gas flow stops GAS indicator off ACTION Open external disconnect RESULT No power to syst...

Страница 39: ...Manual 0 2803 33 APPENDIX...

Страница 40: ...APPENDIX 34 Manual 0 2803 APPENDIX III SYSTEM SCHEMATIC A 02234...

Страница 41: ...Manual 0 2803 35 APPENDIX A 02234 B EC 8055 HAS 11 23 98 C EC 8087 HAS 12 18 98 AE ECO 39F6 ECO 3AF2 HAS 09 15 2001...

Страница 42: ......

Отзывы: