Manual 0-2803
11
INSTALLATION PROCEDURES
SECTION 3:
INSTALLATION
PROCEDURES
3.01 Introduction
NOTE
Depending on how the system was ordered, some
Power Supply Options may already be installed.
If option(s) have been factory installed some of the
instructions may not apply. It is recommended
that all sub-sections be read for general informa-
tion.
This Section describes installation of the Power Supply
and connecting the Torch.
These instructions apply to the Power Supply only; in-
stallation procedures for the Torch, Options, and Acces-
sories are given in Manuals specifically provided for those
units.
The complete installation consists of:
1. Site selection
2. Unpacking
3. Connections to Power Supply
a. Input power
b. Gas
c. Work cable
d. Torch Leads
4. Grounding
5. Operator training
3.02 Site Selection
Select a clean, dry location with good ventilation and ad-
equate working space around all components.
NOTE
Review Important Safety Precautions (page 1) to
be sure that the selected location meets all safety
requirements.
The power supply is fan cooled by air flow through the
front panel to the rear panel. Air flow must not be ob-
structed. Provide at least 2 feet (0.61 m) in the rear and at
least 6 inches (0.15 m) on each side for clearance . Pro-
vide sufficient clearance in front of the unit to allow ac-
cess to the front panel controls (minimum 6 inches or 0.15
m).
CAUTION
Operation without proper air flow will inhibit
proper cooling and reduce duty cycle.
3.03 Unpacking
NOTE
Equipment that was ordered as a system is pack-
aged in one shipping carton. All options and the
Torch are factory installed.
1. Unpack each item and remove all packing material.
2. Locate the packing list(s) and use the list to identify
and account for each item.
3. Inspect each item for possible shipping damage. If
damage is evident, contact your distributor and/or
shipping company before proceeding with system in-
stallation.
3.04 Lifting Options
WARNINGS
Do not touch live electrical parts.
Disconnect input power conductors from de-ener-
gized supply line before moving unit.
This unit is equipped with one handle mounted onto the
top of the enclosure for hand carrying purposes.
WARNING
FALLING EQUIPMENT
can cause serious per-
sonal injury and equipment damage.
• Lift unit with the handle on top of the enclosure.
• Only persons of adequate physical strength should
lift the unit.
• Use hand cart or similar device of adequate capac-
ity.
• If using a fork lift vehicle, place and secure unit on a
proper skid before transporting.
Содержание FP-80
Страница 1: ...Manual No 0 2803 November 7 2001 Plasma Cutting Power Supply Model FP 80 Operating Manual A 02218...
Страница 2: ......
Страница 6: ......
Страница 24: ...INSTALLATION PROCEDURES 18 Manual 0 2803...
Страница 34: ...SERVICE 28 Manual 0 2803...
Страница 39: ...Manual 0 2803 33 APPENDIX...
Страница 40: ...APPENDIX 34 Manual 0 2803 APPENDIX III SYSTEM SCHEMATIC A 02234...
Страница 42: ......