Firenzo Woodfires 102107 Скачать руководство пользователя страница 25

Forte Flush & Athena Flush AG/RURAL 

-

 November 2018

 

 

 25

 

 

RE

-

LOADING AFTER AN EXTENDED BURN TIME

 

 

At the end of an extended burn, re

-

establish the fire by adding a few small split logs, adjust 

the  Air  Control  to  HIGH  and  allow  the  firebox  temperature  to  build  up  before  adding  the       
balance of the fuel, 

loading logs in a side to side configuration

.

 

The  addition  of  large quantities of  cold fuel  to  a  low  fire will  reduce  the firebox  temperature            
dramatically and this may result in 

losing

’ 

the fire.

 

Proceed with fire as before.

 

Do  NOT  operate  the  Fire  with  the  door  constantly  open,  this  overrides  the  Air  Control        
System and greatly lowers optimum heat output and efficiency.

 

FUEL:

 

Dry, seasoned soft wood should be used at all times with a moisture content of less than 25% 
dry weight. 

 

The heat output level on the Fire is controlled not only by the Air Control but also by the type 
and quantity of fuel in the firebox.

 

A fully loaded firebox set to HIGH will produce far more heat than an almost empty Fire set at 
the same    position.  Remember, you only get out of any Fire what you put into it. The   better 
the fuel, the better the Fire

 

Do NOT burn plastic, household refuse or driftwood. This will void any Warranty and reduce 
the lifespan of the fire.

 

 

FLAMMABLE LIQUIDS

 

CAUTION:  

Never use gasoline

-

type fuel, kerosene, charcoal lighter fuel or similar liquids to 

start or 

freshen

-

up

’ 

a fire in this Fire.

 

 

CLEANING THE ASHES FROM THE FIRE

 

Disposal of Ashes:

 

Ashes should be placed in a metal container with a tight fitting lid.  The closed container of 
ashes  should  be  placed  on  a  non

-

combustible  floor  or  on  the  ground,  well  away  from  all    

combustible   materials, pending final disposal, if the ashes are disposed of by burial in soil or 
otherwise locally  dispersed, they should be retained in the closed container until all cinders 
have thoroughly cooled.

 

 

A LAYER OF ASH AT LEAST 25MM DEEP SHOULD ALWAYS BE LEFT IN THE BOTTOM 
OF THE FIREBOX AND IT WILL ALSO ACT AS 

INSULATION

’ 

FOR THE FIRE.

 

 

WARNING

DO NOT REMOVE EXCESS ASH FROM THE FIREBOX BY VACUUM  UNLESS 

THE  FIRE  HAS  BEEN  OUT  FOR  5  OR  MORE  DAYS 

-

  EMBERS  WILL  SMOULDER  FOR 

SEVERAL DAYS AND WILL IGNITE VACUUM CLEANER BAGS.

 

Содержание 102107

Страница 1: ...someone competent to do so Firenzo recommend the use of a NZ Home Heating Association solid fuel Fire installation technician SFAIT or other suitably qualified person The Fire and Flue System must be installed in accordance with AS NZS2918 All installations must be in accordance with these instructions Consult with the building authority having jurisdiction to determine the need for a permit prior...

Страница 2: ...17 6 Assembly Instructions 18 Typical Insert Installation 19 7 Wetback 20 8 Insert Flue System 21 Fascade Chase Termination 22 Minimum Height of Flue Outlet 23 9 Fascia Assembly Installation 24 10 Operating Instructions 25 Operating Instructions 26 11 Maintenance 27 12 13 Maintenance 28 30 14 Warranties Your Warranties Registration Card is enclosed please complete and return to us Under our policy...

Страница 3: ...o not use FLAMMABLE LIQUIDS or AEROSOLS in the vicinity of this Fire when it is operating Use caution when reloading with fuel Do NOT attempt to load fuel into the Fire when the fire inside the stove is at or near its peak Do NOT burn large quantities of paper or combustible material that would create an extremely hot quick fire Do NOT burn highly coloured paper or brochures junk mail USE ONLY DRY...

Страница 4: ...hese installation instructions or any doubt about them must be checked against the requirements of the standards Please leave this manual with the owner when installation is complete 3 FLOOR PROTECTOR REQUIREMENTS If the Fire is to be placed on or within 500mm of a heat sensitive floor an insulated floor protector will be required The insulated floor protector needs to extend under the Fire and in...

Страница 5: ...stallation the standard front clearance from the fireplace breast brickwork etc can be reduced by increasing floor protector height INSERT FLOOR PROTECTOR DEPTH HEIGHT FROM FIRE BREAST Level 520mm 20mm 490mm 40mm 400mm 60mm 400mm Min FLOOR PROTECTOR DIMENSIONS WHEN INSTALLING IN A ZERO CLEARANCE BOX Built in Fire Canopy HEIGHT FROM FIRE BREAST 40mm 500mm ...

Страница 6: ...Forte Flush Athena Flush AG RURAL November 2018 6 ZERO CLEARANCE BOX Built in Fire Canopy Refer page 7 for Built in Fire Canopy Dimensions ...

Страница 7: ...18 7 4 ZERO CLEAREANCE BOX Built in Fire Canopy A Zero Clearance Box is required if the fire is not being installed into a masonry fire place For Zero Clearance Box installations see the following pages 7 15 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 8: ...Forte Flush Athena Flush AG RURAL November 2018 8 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 9: ...Forte Flush Athena Flush AG RURAL November 2018 9 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 10: ...Forte Flush Athena Flush AG RURAL November 2018 10 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 11: ...Forte Flush Athena Flush AG RURAL November 2018 11 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 12: ...Forte Flush Athena Flush AG RURAL November 2018 12 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 13: ...Forte Flush Athena Flush AG RURAL November 2018 13 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 14: ...Forte Flush Athena Flush AG RURAL November 2018 14 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 15: ...Forte Flush Athena Flush AG RURAL November 2018 15 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 16: ...ial MANTEL Masonry Fireplace If the mantel shelf is of a combustible material there should be a minimum distance above the top of the fascia of 400mm This may be reduced if a deflector or heat shield is fitted under the mantel MANTEL using ZERO CLEARANCE BOX Built in Fire Canopy FORTE Can NOT have a combustible mantel however if the mantel is made of a non heat sensitive material then the minimum ...

Страница 17: ...e as per instructions on Page 20 21 if installing in a Masonry Fireplace or pages 8 9 10 11 12 15 if using a Zero Clearance Box Built in Fire Canopy 6 Now that the firebox and flue are in position place 25mm White Kaowool Blanket supplied on top of casing 7 As this fire sources its combustion air from the chimney cavity enclosure the fire MUST be sealed around the front between the casing and the ...

Страница 18: ...Forte Flush Athena Flush AG RURAL November 2018 18 ...

Страница 19: ...Forte Flush Athena Flush AG RURAL November 2018 19 7 WETBACK ...

Страница 20: ...equired 2 Assemble flue ensuring all seams are in line and assembly is straight and tight with crimped ends pointing downwards Secure flue with at least 3 stainless steel or monel rivets and seal 3 Fasten chimney plate supplied onto the chimney top The chimney plate must be weather sealed with silicone or mortar 4 Install chimney liner on top of the chimney plate 5 Ensure flue is extended over the...

Страница 21: ...Forte Flush Athena Flush AG RURAL November 2018 21 ...

Страница 22: ...p of the floor protector 2 The flue cowl must be at least 600mm above the highest point of the roof if within 3 me tres of it or 1 metre above the roof penetration if more than 3 metres from the ridge 3 No part of the building or any adjacent building may be in or above a circular area of a horizontal radius of 3 metres from the flue exit ...

Страница 23: ...o 6mm screws in body and tighten 7 The screw on the bay section may now require adjusting to support canopy 8 Fit upper cast grill on side locaters FORTE WITH FLUSH DOOR 1 Remove screws fixed to lugs on firebox side 2 Place pre assembled fascia against firebox position left hand slip behind hinges and secure the screw Place right hand slip against fascia and secure 3 Set the machine screw on the t...

Страница 24: ...5 Open door carefully and place small pieces then larger logs on top 6 Close door tight and leave Air Control on HIGH for some 30 minutes The value in establishing this technique is that you are providing an excellent base for burning your wood effectively 7 When a good fire is established move air control to middle position DO NOT IMMEDIATELY SHUT THE FIRE TO LOW Remember to close the air control...

Страница 25: ...n an almost empty Fire set at the same position Remember you only get out of any Fire what you put into it The better the fuel the better the Fire Do NOT burn plastic household refuse or driftwood This will void any Warranty and reduce the lifespan of the fire FLAMMABLE LIQUIDS CAUTION Never use gasoline type fuel kerosene charcoal lighter fuel or similar liquids to start or freshen up a fire in t...

Страница 26: ...note of the manufacturer s instructions for spraying Never spray a hot fire BLACK OR SILVER PLATED RAILS The black or silver plated rails must not come in contact with abrasive materials Use a clean damp cloth when the Fire is cool if cleaning is required FIRE BRICKS The internal fire bricks on the sides and base of the firebox can crack in extreme heat However they are safe to leave as is until t...

Страница 27: ...nsulating material for the glass should be replaced at this time also NEVER place glass directly against the door Without the insulation seal tape in place the glass is likely to shatter Your Firenzo agent will be able to supply any spare parts 13 SAFETY All surfaces on the inserts will get hot and cause burning if touched by bare hands Firenzo recommends using a fireguard The heat from inserts wi...

Страница 28: ...sumer Guarantees Act 1993 To the fullest extent permitted at law no other warranties or guarantees express or implied are assumed or given by Firenzo to any person with respect to the quality merchantability description or fitness for purpose or use of Firenzo wood fires or their component parts and materials 6 Firenzo is not liable for and to the maximum extent permitted by law excludes any liabi...

Страница 29: ...ials covered by the warranties or the entire Firenzo wood fire at its discretion where Firenzo is reasonably satisfied a defect is solely due to faulty Firenzo workmanship or materials 14 Firenzo may decline in whole or part to honour a warranty claim until any amounts due but unpaid by a consumer in respect of the Firenzo wood fire or its servicing are paid until Firenzo is provided with the appl...

Страница 30: ...tions about the warranties or this document please contact Firenzo at its specified address on telephone 06 8438260 by email at firenzo firenzo co nz or via the Firenzo website www firenzo co nz 18 This document is intended to form part of and may be expressly referenced in the terms of sale and purchase by every original New Zealand consumer of a Firenzo wood fire With out limiting that intent by...

Страница 31: ...tessa Encore Lady Kitchener Napier Viking Vision Insert Aqualux Athena Bay Flush Forte Bay Flush Kompact Athena Kompact Deco Kompact Diva Kompact Forte Kompact Plaza Kompact Serenity Topaz 98 Niven Street PO Box 3231 HB Mail Centre Napier 4142 Phone 06 8438260 Website www firenzo co nz email firenzo firenzo co nz ...

Отзывы: