Firenzo Woodfires 102107 Скачать руководство пользователя страница 24

Forte Flush & Athena Flush AG/RURAL 

-

 November 2018

 

 

 24

 

 

10.OPERATING INSTRUCTIONS

 

 

PLEASE READ FULLY BEFORE PROCEEDING ANY FURTHER.

 

KEEP THIS BOOK IN A SAFE PLACE.

 

 

 

Please refer to 

Lighting your Firenzo Woodfire Insert Fire

 leaflet 

 

 

FIRST BURN

 

On  the  INITIAL  LIGHTING  only,  the  high  temperature  paint  finishes  used  on  your  Fire  will  give  off 
smoke and odour for several hours.  As this is a temporary  condition, open doors, windows, etc. to give          
adequate ventilation until passed.

 

1.   Prepare fire by placing crumpled paper in middle of firebox.  Do not use a grate, or  elevate fire.  
Build fire directly on floor of firebox.

 

2.   Pull 

air control knob out fully for high

 (this is the small knob to the right of the door)

 

AIR CONTROL OUT = HIGH. 

 

AIR CONTROL KNOB IN = LOW

 

3.    Arrange  dry  kindling  in 

tepee

” 

style  with  larger  pieces  standing  up  on  each  side.    Ignite    paper     

leaving door ajar until kindling is alight.

 

4.     When  vigorous  flaming  of  the  kindling  subsides  and  embers  begin  to  appear,    reload  with  larger 
wood, placing them in a side to side configuration.

 

5.   Open door carefully and place small pieces, then larger logs on top.     

 

6.   Close door tight and leave Air Control on HIGH for some 30 minutes.  The value in   establishing this 
technique is that you are providing an excellent base for burning your wood  effectively. 

 

7. When a good fire is established move air control to middle position.   

DO NOT IMMEDIATELY SHUT 

THE FIRE TO LOW.  

Remember to close the  air control gradually to your desired level of heat output. It 

is better to take 3

-

4   adjustments to get to the low  setting (extended burn).

 

 

RELOADING

 

WARNING: It is necessary to move the Air Control to HIGH before opening the door.

 

Never open the door when a vigorous fire is in progress.  Wait until the flames have subsided and the 
wood  has  broken  up  into  glowing  embers.    Reload  with  dry  logs,  placing  them  in  a  side  to  side             
configuration

 

 

Leave the air control in the HIGH position for 10 to 15 minutes or until the flames begin to subside.  This 
shows  that  the  initial  highly  volatile  wood  gases  have  been  driven  off  and  the  Fire  will  be  able  to       
maintain an even burning rate.

 

 

Normally a light load of fuel will stabilize quickly but a full load will take longer.  Once the burning rate 
has stabilized move the Air Control to a medium position.

 

Содержание 102107

Страница 1: ...someone competent to do so Firenzo recommend the use of a NZ Home Heating Association solid fuel Fire installation technician SFAIT or other suitably qualified person The Fire and Flue System must be installed in accordance with AS NZS2918 All installations must be in accordance with these instructions Consult with the building authority having jurisdiction to determine the need for a permit prior...

Страница 2: ...17 6 Assembly Instructions 18 Typical Insert Installation 19 7 Wetback 20 8 Insert Flue System 21 Fascade Chase Termination 22 Minimum Height of Flue Outlet 23 9 Fascia Assembly Installation 24 10 Operating Instructions 25 Operating Instructions 26 11 Maintenance 27 12 13 Maintenance 28 30 14 Warranties Your Warranties Registration Card is enclosed please complete and return to us Under our policy...

Страница 3: ...o not use FLAMMABLE LIQUIDS or AEROSOLS in the vicinity of this Fire when it is operating Use caution when reloading with fuel Do NOT attempt to load fuel into the Fire when the fire inside the stove is at or near its peak Do NOT burn large quantities of paper or combustible material that would create an extremely hot quick fire Do NOT burn highly coloured paper or brochures junk mail USE ONLY DRY...

Страница 4: ...hese installation instructions or any doubt about them must be checked against the requirements of the standards Please leave this manual with the owner when installation is complete 3 FLOOR PROTECTOR REQUIREMENTS If the Fire is to be placed on or within 500mm of a heat sensitive floor an insulated floor protector will be required The insulated floor protector needs to extend under the Fire and in...

Страница 5: ...stallation the standard front clearance from the fireplace breast brickwork etc can be reduced by increasing floor protector height INSERT FLOOR PROTECTOR DEPTH HEIGHT FROM FIRE BREAST Level 520mm 20mm 490mm 40mm 400mm 60mm 400mm Min FLOOR PROTECTOR DIMENSIONS WHEN INSTALLING IN A ZERO CLEARANCE BOX Built in Fire Canopy HEIGHT FROM FIRE BREAST 40mm 500mm ...

Страница 6: ...Forte Flush Athena Flush AG RURAL November 2018 6 ZERO CLEARANCE BOX Built in Fire Canopy Refer page 7 for Built in Fire Canopy Dimensions ...

Страница 7: ...18 7 4 ZERO CLEAREANCE BOX Built in Fire Canopy A Zero Clearance Box is required if the fire is not being installed into a masonry fire place For Zero Clearance Box installations see the following pages 7 15 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 8: ...Forte Flush Athena Flush AG RURAL November 2018 8 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 9: ...Forte Flush Athena Flush AG RURAL November 2018 9 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 10: ...Forte Flush Athena Flush AG RURAL November 2018 10 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 11: ...Forte Flush Athena Flush AG RURAL November 2018 11 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 12: ...Forte Flush Athena Flush AG RURAL November 2018 12 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 13: ...Forte Flush Athena Flush AG RURAL November 2018 13 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 14: ...Forte Flush Athena Flush AG RURAL November 2018 14 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 15: ...Forte Flush Athena Flush AG RURAL November 2018 15 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 16: ...ial MANTEL Masonry Fireplace If the mantel shelf is of a combustible material there should be a minimum distance above the top of the fascia of 400mm This may be reduced if a deflector or heat shield is fitted under the mantel MANTEL using ZERO CLEARANCE BOX Built in Fire Canopy FORTE Can NOT have a combustible mantel however if the mantel is made of a non heat sensitive material then the minimum ...

Страница 17: ...e as per instructions on Page 20 21 if installing in a Masonry Fireplace or pages 8 9 10 11 12 15 if using a Zero Clearance Box Built in Fire Canopy 6 Now that the firebox and flue are in position place 25mm White Kaowool Blanket supplied on top of casing 7 As this fire sources its combustion air from the chimney cavity enclosure the fire MUST be sealed around the front between the casing and the ...

Страница 18: ...Forte Flush Athena Flush AG RURAL November 2018 18 ...

Страница 19: ...Forte Flush Athena Flush AG RURAL November 2018 19 7 WETBACK ...

Страница 20: ...equired 2 Assemble flue ensuring all seams are in line and assembly is straight and tight with crimped ends pointing downwards Secure flue with at least 3 stainless steel or monel rivets and seal 3 Fasten chimney plate supplied onto the chimney top The chimney plate must be weather sealed with silicone or mortar 4 Install chimney liner on top of the chimney plate 5 Ensure flue is extended over the...

Страница 21: ...Forte Flush Athena Flush AG RURAL November 2018 21 ...

Страница 22: ...p of the floor protector 2 The flue cowl must be at least 600mm above the highest point of the roof if within 3 me tres of it or 1 metre above the roof penetration if more than 3 metres from the ridge 3 No part of the building or any adjacent building may be in or above a circular area of a horizontal radius of 3 metres from the flue exit ...

Страница 23: ...o 6mm screws in body and tighten 7 The screw on the bay section may now require adjusting to support canopy 8 Fit upper cast grill on side locaters FORTE WITH FLUSH DOOR 1 Remove screws fixed to lugs on firebox side 2 Place pre assembled fascia against firebox position left hand slip behind hinges and secure the screw Place right hand slip against fascia and secure 3 Set the machine screw on the t...

Страница 24: ...5 Open door carefully and place small pieces then larger logs on top 6 Close door tight and leave Air Control on HIGH for some 30 minutes The value in establishing this technique is that you are providing an excellent base for burning your wood effectively 7 When a good fire is established move air control to middle position DO NOT IMMEDIATELY SHUT THE FIRE TO LOW Remember to close the air control...

Страница 25: ...n an almost empty Fire set at the same position Remember you only get out of any Fire what you put into it The better the fuel the better the Fire Do NOT burn plastic household refuse or driftwood This will void any Warranty and reduce the lifespan of the fire FLAMMABLE LIQUIDS CAUTION Never use gasoline type fuel kerosene charcoal lighter fuel or similar liquids to start or freshen up a fire in t...

Страница 26: ...note of the manufacturer s instructions for spraying Never spray a hot fire BLACK OR SILVER PLATED RAILS The black or silver plated rails must not come in contact with abrasive materials Use a clean damp cloth when the Fire is cool if cleaning is required FIRE BRICKS The internal fire bricks on the sides and base of the firebox can crack in extreme heat However they are safe to leave as is until t...

Страница 27: ...nsulating material for the glass should be replaced at this time also NEVER place glass directly against the door Without the insulation seal tape in place the glass is likely to shatter Your Firenzo agent will be able to supply any spare parts 13 SAFETY All surfaces on the inserts will get hot and cause burning if touched by bare hands Firenzo recommends using a fireguard The heat from inserts wi...

Страница 28: ...sumer Guarantees Act 1993 To the fullest extent permitted at law no other warranties or guarantees express or implied are assumed or given by Firenzo to any person with respect to the quality merchantability description or fitness for purpose or use of Firenzo wood fires or their component parts and materials 6 Firenzo is not liable for and to the maximum extent permitted by law excludes any liabi...

Страница 29: ...ials covered by the warranties or the entire Firenzo wood fire at its discretion where Firenzo is reasonably satisfied a defect is solely due to faulty Firenzo workmanship or materials 14 Firenzo may decline in whole or part to honour a warranty claim until any amounts due but unpaid by a consumer in respect of the Firenzo wood fire or its servicing are paid until Firenzo is provided with the appl...

Страница 30: ...tions about the warranties or this document please contact Firenzo at its specified address on telephone 06 8438260 by email at firenzo firenzo co nz or via the Firenzo website www firenzo co nz 18 This document is intended to form part of and may be expressly referenced in the terms of sale and purchase by every original New Zealand consumer of a Firenzo wood fire With out limiting that intent by...

Страница 31: ...tessa Encore Lady Kitchener Napier Viking Vision Insert Aqualux Athena Bay Flush Forte Bay Flush Kompact Athena Kompact Deco Kompact Diva Kompact Forte Kompact Plaza Kompact Serenity Topaz 98 Niven Street PO Box 3231 HB Mail Centre Napier 4142 Phone 06 8438260 Website www firenzo co nz email firenzo firenzo co nz ...

Отзывы: