OD42 Outdoor Gas Fireplace
27
27
INSTALLATION
OPERATING INSTRUCTIONS
FIRST FIRE
The fi rst fi re in your fi replace is part of the paint
curing process. To ensure that the paint is properly
cured, it is recommended that you burn your fi replace
for at least four (4) hours the fi rst time you use it
.
When fi rst operated, the unit will release an odour
caused by the curing of the paint, the burning off of
any oils remaining from manufacturing.
The glass wind shield may require cleaning after
the unit has cooled down.
DO NOT ATTEMPT TO CLEAN THE
GLASS WIND SHIELD WHILE IT IS HOT.
Note: When the glass wind shield is cold and the
appliance is lit, it may cause condensation
and fog the glass. This condensation is
normal and will disappear in a few minutes
as the glass wind shield heats up.
OPERATING
INSTRUCTIONS
1)
Read and understand these instructions before
operating this appliance.
2)
Check to see that all wiring is correct and
enclosed to prevent possible shock.
3)
Check to ensure there are no gas leaks.
4)
Ensure that the stainless panels are installed.
5)
Verify twig placement. If the pilot cannot be
seen when lighting the unit, the twigs have
been incorrectly positioned.
6)
The unit should never be turned off, and on
again without a minimum of a 60 second wait.
LIGHTING PROCEDURE
1)
Turn on ON/OFF switch.
2)
After approximately 4 seconds the spark igni-
tion system will spark for 60 seconds to light
the main burner.
3)
The unit will turn on.
Note:
The fi rst try for ignition will last approximately
60 seconds. If there is no fl ame ignition (rectifi -
cation) the board will stop sparking for approxi-
mately 35 seconds. After wait time , the board
will start second try for ignition by sparking for
approximately 60 seconds . If there is still no
positive ignition the board will go into lock out.
The system will need to be reset as follows:
a)
Turn the system off using ON/OFF switch.
b)
After approximately 2 seconds turn on ON/OFF
switch.
c)
Unit will repeat step 2.
SHUTDOWN
PROCEDURE
1)
Turn ON/OFF switch to OFF.
2)
If service is to be performed - remove batteries
from the battery pack
Содержание OD42-N
Страница 5: ...OD42 Outdoor Gas Fireplace 5 DIMENSIONS UNIT DIMENSIONS WITH 2 FACEPLATE ...
Страница 6: ...6 OD42 Outdoor Gas Fireplace DIMENSIONS UNIT DIMENSIONS WITH 4 FACEPLATE ...
Страница 36: ...36 OD42 Outdoor Gas Fireplace NOTES ...
Страница 37: ...OD42 Outdoor Gas Fireplace 37 NOTES ...
Страница 38: ...38 OD42 Outdoor Gas Fireplace NOTES ...