Firegear Outdoor KWB30
23
INSTALLATION
ASSEMBLY INSTRUCTIONS FOR A STEEL STUD
SEE THROUGH FRAMING KIT FOR KWB30
Follow these instructions for the 30" burner;
**Non-combustible fi nishing board not supplied with kit. Board may be purchased at your local hardware/building supply store.
IMPORTANT:
Supplied vents need to be installed into non-combustible fi nishing board, before applying fi nishing materials. Follow guidelines
included with these instructions.
377-908 CONTENTS:
Top / Bottom
(A) x 2
Vertical Supports - Tall
(B) x 8
Vertical Supports - Short (C) x 6
Base
(D) x 1
Short Brace
(E) x 4
Header
(F) x 2
Vents
4
Wafer Screws
80
Tools Required
1 power
drill
+ #2 phillips bit
1 hand
#2 screwdriver
(Phillips)
1 level
1
tape
measure
Vent Location
Vent Location
Vent Location
Vent Location
NOTE:
Four (4) ventilation grills are required for all enclosures.
This is to alleviate moisture and allow for air to circulate. Minimum recommended size 20" sq (508 mm²)
ea
.
See fi nishing details in instruction manual.
NOTE:
If installing a propane unit, the propane tank (if installed) and the pilot hood assembly, must be at opposite ends. Do not install pilot side of
unit over propane tank.
Overall dimensions: 64-1/16" W x 51" H x 19" D
Opening dimensions: 42" W x 20-1/2" H
Содержание Key West KWB30 KWB-L1