background image

FPB Pro Spur Burners Fire Pits with AWS System

REV. A            Page 22

We are not liable for any special, indirect or consequential damages. Our maximum liability is limited to the 

purchase price of the purchased units. Some states do not allow the exclusion or limitation of incidental or 

consequential damages, so this limitation or exclusion may not apply to you. 

 

We do not authorize any person or company to assume for it any other obligation or liability in connection 

with the sale, installation, use, removal, return, or replacement of its equipment, and or such representation 

are binding. 

 

 

Firegear Outdoors 

17322 Gothard Street, Huntington Beach, CA 92647 

www.firegearoutdoors.com 

Phone: 800-966-8126 

Email: [email protected] 

Manual changes often occur, ensure to check the Firegear Outdoor 

website for any recent updates and warranty information.

FOR TECHNICAL SERVICE, CALL:

Firegear Outdoors

17322 Gothard St

Huntington Beach, CA 92647

Web Site:  www.firegearoutdoors.com

(800) 966-8126

Содержание FPB-19RPSBR14AWS-N

Страница 1: ...rovide proper ventilation will void the warranty Natural Gas Models Propane Gas Models Description FPB 19RPSBR14AWS N FPB 19RPSBR14AWS P 19 Round Pan with 14 Pro Brass Burner FPB 25RPSBR21AWS N FPB 25...

Страница 2: ...ff gas to the appliance 2 Extinguish any open flame 3 If odor continues keep away from the appliance and immediately call your gas supplier or fire department DANGER WARNING Do not store or use gasoli...

Страница 3: ...lame from distance to ensure that all popping has ceased before fully enjoying the fire CAUTION TABLE OF CONTENTS Specifications 4 Carton Contents Single Fire Feature 5 Preparing a Non Combustible Str...

Страница 4: ...As a result your Btu s may vary slightly from Table 2 specifications Table 2 Burner specifications Natural Gas Models Propane Gas Models A Depth B Min Max Opening C Inside Pan Dimension D Ground Level...

Страница 5: ...on of the stainless steel flex gas line not supplied with the fire feature see Fig 5 page 9 5 Do not place an LP tank inside any fire pit enclosure Locate all Liquid Propane LP tanks outside the enclo...

Страница 6: ...es required for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have pro...

Страница 7: ...nut connec tions and connectors to prevent moisture issues from the outdoor environment The AWS system is polarity sensitive There is a red sleeve attached to the positive side of the adapter When wir...

Страница 8: ...sure the flame is a safe and reasonable height to not pose a risk to people or property Note The Firegear Pro Series brass burners DO NOT USE a primary main burner orifice like a standard stainless st...

Страница 9: ...lled inside the enclosure due to the wire length limitations The power cord is 3 feet long the 30VDC leads to the valve are 3 feet long See Fig 5 Fig 7 Example of a single fire feature install with po...

Страница 10: ...in detail enables the ability to remove the pan disc to service valve system Flex Frame Optional ON OFF Controls Note Actual power supply must be 10 feet or more from the pool or spa DETAIL Pool Contr...

Страница 11: ...S IMPORTANT DO NOT PLACE ROCK OVER TOP OR UNDER THE PILOT SCREEN COVER The screen must be free of any debris to ensure proper lighting of burner and good flame sense See Fig 13 Cover the burner comple...

Страница 12: ...r LP gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance READ ALL LIGHTING INSTRUCTIONS BEFORE ATTEMPTING TO...

Страница 13: ...REV A Page 13 FPB Pro Spur Burners Fire Pits with AWS System AWS REPLACEMENT PARTS GOE 30DCV OUT 1 4 3 2 5 6 7 8 9 10 Items are not to scale...

Страница 14: ...rner Cage hood 1 FG PBC 8 Thermopile for primary pilot assembly 1 FG TP 9 Hot Surface Ignition for pilot burner assembly item 2 1 FG HSI 10 Heat Shield 1 FG HEATSHIELD 11 Rocker Switch installs into 7...

Страница 15: ...r If for some reason someone connected 120VAC power directly to the gas valve the controller inside the valve box will be damaged It this happens a burned electrical smell might be present Connector N...

Страница 16: ...osen the thermopile from the pilot assembly and slide it out If it will not slide out because is it too tight then it will need to be replaced Debris Debris can get trapped inside the screen of the ga...

Страница 17: ...effect Remove some of the fire glass media from the burner to see if this fixes the problem Gas Leak Natural Gas is lighter than air therefore when released into the atmosphere it rises If you have a...

Страница 18: ...when using paver blocks or other non combustible enclosures Glass Windshields See catalog for a windshield to fit your application Shut Off Valves Model 01 387 OD Flare x FIP Model 01 487 OD Flare x F...

Страница 19: ...VE 5 YEAR WARRANTY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME...

Страница 20: ...FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR...

Страница 21: ...to repair the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and r...

Страница 22: ...company to assume for it any other obligation or liability in connection with the sale installation use removal return or replacement of its equipment and or such representation are binding Firegear O...

Страница 23: ...________ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6...

Отзывы: