background image

REV. A  Page 6

T- Burner Kit

REV. A  Page 7

REQUIREMENTS

1.  Only non-combustible materials should come in direct contact with any part of the fire pit. Underneath area should  

be non-combustible or a flat level combustible surface according to the clearances specified in this manual.

2.  Refer to the NFPA54 (National Fuel Gas Code) for proper pipe sizing. Determine the size of the fire pit you are      

preparing to install (Refer to page 6, Table 4).

3.  Determine the size of the round or square fire pit you are preparing to install (Refer to page 4).
4.  You must provide a round or square opening out to place the fire pit into the non-combustible enclosure.  A minimum  

burner pan dimension is listed in Table 1.

5.  Follow the local code requirements for the gas type being used. This fire pit should be installed in accordance with  

local codes and ordinances or in the absence of local codes, with the latest National Fuel Gas Code, ANSI Z223.1   

NFPA54 or CSA B149.1, Natural and Propane Installation Code in Canada.

6.  Fire pits create high temperatures, it is very important to have any combustibles at a safe distance. 
7.  Do not fill the enclosure with gravel, rock or sand.  The enclosure requires free flowing air underneath to keep       

enclosure cool, provide ventilation to prevent moisture, and provide an outlet for gas in the case of a gas leak. 

8.  CAUTION: A minimum of 18 square inches of cross ventilation (opposite sides) is required to keep the      

enclosure dry.

9.  These products are designed for outdoor use only. 

Not approved for any indoor use or any enclosed space. 

10. This fire pit is designed to have Firegear Outdoors lava rock or glass media completely covering the burner tube, 

so that the burner is not visible. Do not cover more than 1” above the top of burner. Use lava rock a minimum of 1” 

diameter as a base to fill the burner pan. DO NOT USE STONE OR RIVER ROCK.

11.  Gas lines and fittings must be installed in to the non-combustible structure. All gas connections must be leak tested  

before installation of the fire pit. Soapy water leak detection is required before regular use of the fire pit.

12. Do not use material that will absorb moisture over time and will not release this moisture quickly. Moisture can boil  

in this material and can rapidly break apart and cause damage or personal injury.

13. Never leave any other combustible material on top of the fire pit. This could cause unsafe operation of this system  

and damage to the component that will not be covered under our warranty.

14. Ensure proper water drainage is also incorporated into the fire pit enclosure.

INSTALLATION OF FIRE PIT INTO AN APPROVED ENCLOSURE

Содержание FG-T-21SS

Страница 1: ...Burner FG T 69SSK 69 T Burner Kit 150 000 Btu s FG T 81SS 81 T Burner FG T 81SSK 81 T Burner Kit 175 000 Btu s FG T 93SS 93 T Burner FG T 93SSK 93 T Burner Kit 200 000 Btu s Installation and Operating...

Страница 2: ...DANGER WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicinity...

Страница 3: ...fire feature WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling however heavy rains high humidity and the presence of moisture...

Страница 4: ...2 3 69 72 x 6 8 36 96 18 1 FG T 81SS FG T 81SSK 2 3 81 84 x 6 8 36 120 18 1 FG T 93SS FG T 93SSK 2 3 93 96 x 6 8 36 120 18 1 Disclaimer Btu listings are based on 7 0 WC for Natural Gas and 11 0 WC fo...

Страница 5: ...pane tank less than 100lbs capacity IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier This appliance must be isolated from the gas supp...

Страница 6: ...e sizes required for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will hav...

Страница 7: ...enclosure cool provide ventilation to prevent moisture and provide an outlet for gas in the case of a gas leak 8 CAUTION A minimum of 18 square inches of cross ventilation opposite sides is required...

Страница 8: ...the pan See Fig 4 then install the OAS and U3 8D S to the nipple connect inlet gas line as shown in Fig 5 7 8 to 1 Inch Center Hole Fig 3 Minimum center clearance hole in burner pan ALL T BURNER MODE...

Страница 9: ...Outdoors See replacement parts list in manual for model numbers INSTALLING KEY VALVE INSTALLATION OF LAVA ROCK MEDIA INTO BURNER PAN Install lava rock into the burner pan Ensure the lava rock is a 1 i...

Страница 10: ...y Key Valve Side View Det a i l Fig 5 Typical installation NOTE Key valve and flexible gas lines are supplied Gas shut off is not supplied Note A 1 x 2 black iron or galvanized coupler nipple not supp...

Страница 11: ...e of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when opera...

Страница 12: ...T Burner Kit REV A Page 12 REPLACEMENT PARTS 2 3 Drawings not to scale 5 2a 4 O N O F F 4a 6 1 7...

Страница 13: ...0612 1 81 T Burner Burner Only used with FG T 81SS or FG T 81SSK 1 10617 1 93 T Burner Burner Only used with FG T 93SS or FG T 93SSK 1 10618 2 2a OAS Orifice Air Shutter for Natural Gas or LP Gas Fire...

Страница 14: ...S LP Orifice Flared Fitting U3 8D S x Coupling Fig 11 Proper LP conversion illustration Fig 12 Optional LP conversion illustration shows a 90 elbow not supplied Burner Pan x 5 inch Black Iron Nipple 1...

Страница 15: ...mbustible type cover is used over the fire pit when not in use be sure to remove it before operation to prevent a severe safety hazard 5 Over time stainless steel parts can discolor when heated usuall...

Страница 16: ...Y REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRU...

Страница 17: ...BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR WARRANTY SKYTECH...

Страница 18: ...fect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Firege...

Страница 19: ...consequential damages so this limitation or exclusion may not apply to you We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale ins...

Отзывы: