background image

REV. A  Page 12

T- Burner Kit

REV. A  Page 13

REPLACEMENT PARTS 

1

21” T-Burner Burner Only  (used with FG-T-21SS or FG-T-21SSK)

1

10615

1

27” T-Burner Burner Only  (used with FG-T-27SS or FG-T-27SSK)

1

10600

1

33” T-Burner Burner Only  (used with FG-T-33SS or FG-T-33SSK)

1

10601

1

45” T-Burner Burner Only  (used with FG-T-45SS or FG-T-45SSK)

1

10602

1

57” T-Burner Burner Only  (used with FG-T-57SS or FG-T-57SSK)

1

10603

1

69” T-Burner Burner Only  (used with FG-T-69SS or FG-T-69SSK)

1

10612

1

81” T-Burner Burner Only  (used with FG-T-81SS or FG-T-81SSK)

1

10617

1

93” T-Burner Burner Only  (used with FG-T-93SS or FG-T-93SSK)

1

10618

2

2a

OAS (Orifice Air Shutter) for Natural Gas or LP Gas Fire Pits

1

Refer to Table 2 

on page 4

3

1/2” Flex Gas Line (46-inch Length) (used with all kits)

1

T200-9898-46

4

High Capacity Key Valve

1

BVL2S

4a Chrome Plated Flange Cover (used with BVL2S key valve)

1

CVR-BVL2CP

5

8-inch Chrome Key (used with all key valves)

1

8” or 12”

6

½” Flare to 1½” FIP Fitting (used with all DBS Kits)

1

48-88

Item

Description

Qty.

Part Number

See the Firegear Outdoors catalogue for a variety of fittings and flex connectors also available.

Содержание FG-T-21SS

Страница 1: ...Burner FG T 69SSK 69 T Burner Kit 150 000 Btu s FG T 81SS 81 T Burner FG T 81SSK 81 T Burner Kit 175 000 Btu s FG T 93SS 93 T Burner FG T 93SSK 93 T Burner Kit 200 000 Btu s Installation and Operating...

Страница 2: ...DANGER WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicinity...

Страница 3: ...fire feature WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling however heavy rains high humidity and the presence of moisture...

Страница 4: ...2 3 69 72 x 6 8 36 96 18 1 FG T 81SS FG T 81SSK 2 3 81 84 x 6 8 36 120 18 1 FG T 93SS FG T 93SSK 2 3 93 96 x 6 8 36 120 18 1 Disclaimer Btu listings are based on 7 0 WC for Natural Gas and 11 0 WC fo...

Страница 5: ...pane tank less than 100lbs capacity IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier This appliance must be isolated from the gas supp...

Страница 6: ...e sizes required for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will hav...

Страница 7: ...enclosure cool provide ventilation to prevent moisture and provide an outlet for gas in the case of a gas leak 8 CAUTION A minimum of 18 square inches of cross ventilation opposite sides is required...

Страница 8: ...the pan See Fig 4 then install the OAS and U3 8D S to the nipple connect inlet gas line as shown in Fig 5 7 8 to 1 Inch Center Hole Fig 3 Minimum center clearance hole in burner pan ALL T BURNER MODE...

Страница 9: ...Outdoors See replacement parts list in manual for model numbers INSTALLING KEY VALVE INSTALLATION OF LAVA ROCK MEDIA INTO BURNER PAN Install lava rock into the burner pan Ensure the lava rock is a 1 i...

Страница 10: ...y Key Valve Side View Det a i l Fig 5 Typical installation NOTE Key valve and flexible gas lines are supplied Gas shut off is not supplied Note A 1 x 2 black iron or galvanized coupler nipple not supp...

Страница 11: ...e of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when opera...

Страница 12: ...T Burner Kit REV A Page 12 REPLACEMENT PARTS 2 3 Drawings not to scale 5 2a 4 O N O F F 4a 6 1 7...

Страница 13: ...0612 1 81 T Burner Burner Only used with FG T 81SS or FG T 81SSK 1 10617 1 93 T Burner Burner Only used with FG T 93SS or FG T 93SSK 1 10618 2 2a OAS Orifice Air Shutter for Natural Gas or LP Gas Fire...

Страница 14: ...S LP Orifice Flared Fitting U3 8D S x Coupling Fig 11 Proper LP conversion illustration Fig 12 Optional LP conversion illustration shows a 90 elbow not supplied Burner Pan x 5 inch Black Iron Nipple 1...

Страница 15: ...mbustible type cover is used over the fire pit when not in use be sure to remove it before operation to prevent a severe safety hazard 5 Over time stainless steel parts can discolor when heated usuall...

Страница 16: ...Y REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRU...

Страница 17: ...BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR WARRANTY SKYTECH...

Страница 18: ...fect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Firege...

Страница 19: ...consequential damages so this limitation or exclusion may not apply to you We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale ins...

Отзывы: