background image

T- Burner Kit

REV. A  Page 18

The end-user must provide a bill of sale, canceled check, or payment record to verify the purchase date and to 

establish the warranty period. This Limited Warranty shall be valid and limited to the original purchaser only. 

 

WARNING

    Any modification to the product will void the warranty. 

This Limited Warranty shall be limited to the repair and/or replacement of parts that have been proven to be 

defective under normal use and service. All warranty claims must be made by the OEM/Distributor/Dealer 

account on behalf of the end-user. You may contact Technical Support at 800-966-8126. 

 

Our Technical Service Department must confirm all approved defects. If a defect is confirmed and we approve 

the claim, we will replace such parts without charge. This warranty gives you specific legal rights, and you may 

also have other rights, which vary from state to state. 

The manufacturer may request defective products returned with an RMA (Return Merchandise Authorization) 

issued by Firegear Outdoors for specific products, which is considered to be the nature of the defect and or 

warranty claim. Product to be returned should; be packed so as not to incur damages during transportation. 

Firegear is not responsible for damages on returned items. RMA is valid for thirty (30) days from the date 

issued. The RMA must be clearly marked on the outside of the package. 

 

Please check with your local building code department or governing agency for proper approvals before 

purchasing. Firegear Outdoors is not responsible for any violation of local codes. 

 

Travel, diagnostic cost, service labor to repair the defect on warranty parts to and from the factory will be the 

responsibility of the owner.  We will not be responsible for labor charges and/or damage incurred in 

installation, repair, and replacement.  Firegear is not responsible for Issues related to gas or electrical 

installation.   

 

The Limited Warranty is voided if not assembled, installed, and operated as intended. This Limited Warranty 

does not cover any defects due to accident, abuse, misuse, alteration, misapplication, vandalism, improper 

installation or improper maintenance or service, removal from the original location, or re-installation into 

another location, or failure to perform normal and routine maintenance. 

 

Damage due to severe weather conditions such as hail, hurricanes, earthquakes, tornadoes, discoloration due 

to overheating, exposure to chemicals (including chlorine and salt), either directly or in the atmosphere, or 

very high humidity, is not covered by this Limited Warranty. Costal, humid and/or salt environments are 

subject to manufacturer review. All out-of-box claims must be made within 30 days of purchase and must be 

made prior to installation. Any product installed damaged will be considered damaged during installation and 

not covered under warranty. 

 

There are no other express warranties except as set forth herein. For consumer applications, any applicable 

implied warranties of merchantability and fitness are limited induration to the period of coverage of this 

Limited Warranty. Some states do not allow limitation on how long an implied warranty lasts, so this limitation 

may not apply to you. 

 

For Commercial Applications, the liability of Firegear Outdoors is limited to the express terms of this warranty. 

We expressly disclaim any and all implied warranties, including any warranties of fitness for a particular 

purpose or merchantability. 

 

Содержание FG-T-21SS

Страница 1: ...Burner FG T 69SSK 69 T Burner Kit 150 000 Btu s FG T 81SS 81 T Burner FG T 81SSK 81 T Burner Kit 175 000 Btu s FG T 93SS 93 T Burner FG T 93SSK 93 T Burner Kit 200 000 Btu s Installation and Operating...

Страница 2: ...DANGER WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicinity...

Страница 3: ...fire feature WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling however heavy rains high humidity and the presence of moisture...

Страница 4: ...2 3 69 72 x 6 8 36 96 18 1 FG T 81SS FG T 81SSK 2 3 81 84 x 6 8 36 120 18 1 FG T 93SS FG T 93SSK 2 3 93 96 x 6 8 36 120 18 1 Disclaimer Btu listings are based on 7 0 WC for Natural Gas and 11 0 WC fo...

Страница 5: ...pane tank less than 100lbs capacity IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier This appliance must be isolated from the gas supp...

Страница 6: ...e sizes required for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will hav...

Страница 7: ...enclosure cool provide ventilation to prevent moisture and provide an outlet for gas in the case of a gas leak 8 CAUTION A minimum of 18 square inches of cross ventilation opposite sides is required...

Страница 8: ...the pan See Fig 4 then install the OAS and U3 8D S to the nipple connect inlet gas line as shown in Fig 5 7 8 to 1 Inch Center Hole Fig 3 Minimum center clearance hole in burner pan ALL T BURNER MODE...

Страница 9: ...Outdoors See replacement parts list in manual for model numbers INSTALLING KEY VALVE INSTALLATION OF LAVA ROCK MEDIA INTO BURNER PAN Install lava rock into the burner pan Ensure the lava rock is a 1 i...

Страница 10: ...y Key Valve Side View Det a i l Fig 5 Typical installation NOTE Key valve and flexible gas lines are supplied Gas shut off is not supplied Note A 1 x 2 black iron or galvanized coupler nipple not supp...

Страница 11: ...e of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when opera...

Страница 12: ...T Burner Kit REV A Page 12 REPLACEMENT PARTS 2 3 Drawings not to scale 5 2a 4 O N O F F 4a 6 1 7...

Страница 13: ...0612 1 81 T Burner Burner Only used with FG T 81SS or FG T 81SSK 1 10617 1 93 T Burner Burner Only used with FG T 93SS or FG T 93SSK 1 10618 2 2a OAS Orifice Air Shutter for Natural Gas or LP Gas Fire...

Страница 14: ...S LP Orifice Flared Fitting U3 8D S x Coupling Fig 11 Proper LP conversion illustration Fig 12 Optional LP conversion illustration shows a 90 elbow not supplied Burner Pan x 5 inch Black Iron Nipple 1...

Страница 15: ...mbustible type cover is used over the fire pit when not in use be sure to remove it before operation to prevent a severe safety hazard 5 Over time stainless steel parts can discolor when heated usuall...

Страница 16: ...Y REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRU...

Страница 17: ...BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR WARRANTY SKYTECH...

Страница 18: ...fect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Firege...

Страница 19: ...consequential damages so this limitation or exclusion may not apply to you We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale ins...

Отзывы: