Fireboy- Xintex CMD6-MB Скачать руководство пользователя страница 7

 

 

 

 

Part Number

 

18160, F, 06/29/2021

 

 

Limitations 

 

This carbon monoxide alarm is designed to detect carbon monoxide gas from ANY 
source of combustion.  It is NOT designed to detect smoke, fire or any other gas. 

 

The CO Alarm will not detect carbon monoxide that is not in the vicinity of the alarm.  
Carbon monoxide in other rooms or areas will not be detected.  Alarms mounted near 

obstructions or in ‘dead’ air spaces will not detect carbon monoxide.

 

 

The CO Alarm does not guarantee or imply that CO poisoning will not occur.  Do NOT 
use the CO Alarm as a replacement for ordinary precautions or periodic inspections of 
equipment.  NEVER rely on alarm systems to save your life, common sense is still 
prudent and necessary. 

 

The audible horn on the CO Alarm meets UL STD 2034 Marine requirements; however, 
the horn may not be heard in remote areas. 

 

The nature of an alarm system is to produce an irritating and loud noise.  The audible 
signal of the CO Alarm may shock or startle persons near the alarm.  Hearing damage 
can occur if prolonged exposure to the audible alarm is allowed. 

 

All electric devices have limited life spans and may fail without warning.  Inspect the CO 
Alarm on a periodic basis.  Do NOT assume that the CO Alarm will prevent CO poisoning.  
It is a supplement-warning device only. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание CMD6-MB

Страница 1: ...nect Relay Black Housing CMD6 MD Marine 12 24V DC CMD6 MD B Marine 12 24V DC Black Housing CMD6 MDR Marine 12 24V DC Interconnect Relay CMD6 MDR B Marine 12 24V DC Interconnect Relay Black Housing Own...

Страница 2: ...lling the Mounting Base 12 Connecting Alarm to Mounting Base 13 Wiring Connections Marine 12 24V DC Units 14 Wiring Connections Marine Battery Units 15 Activating Fireboy Xintex Carbon Monoxide Alarm...

Страница 3: ...TO PROTECT INDIVIDUALS FROM THE ACUTE EFFECTS OF CARBON MONOXIDE EXPOSURE IT WILL NOT FULLY SAFEGUARD INDIVIDUALS WITH SPECIFIC MEDICAL CONDITIONS IF IN DOUBT CONSULT A MEDICAL PRACTITIONER ANY PERSO...

Страница 4: ...evices All of these produce large amounts of CO and should never be operated while occupants are sleeping A slight build up of carbon monoxide in the human body over several hours causes headaches nau...

Страница 5: ...ove situations Extended operation of un vented fuel burning devices range oven etc Temperature inversions that can trap exhaust gases near the ground Drug or alcohol use increases the effect of CO exp...

Страница 6: ...of propulsion and auxiliary generators frequently for possible leaks High concentrations of CO in your boat may originate from an adjacent boat Exhaust fumes from nearby boats may enter your boat thro...

Страница 7: ...as a replacement for ordinary precautions or periodic inspections of equipment NEVER rely on alarm systems to save your life common sense is still prudent and necessary The audible horn on the CO Alar...

Страница 8: ...9 32V DC Nominal Current Draw 40 F 40 C to 158 F 70 C 6mA Maximum Current Draw 40 F 40 C to 158 F 70 C 38mA 32V DC Operating Storage Temperature 22 F 30 C to 158 F 70 C Alarm Points Time Weighted Ave...

Страница 9: ...such as when docking or maneuvering The CO Alarm takes this all under consideration by totaling the quantity of CO detected over a period of time The CO Alarm is programmed to alarm at a COHb level of...

Страница 10: ...OR MOVE AWAY FROM THE OPEN DOOR WINDOW UNTIL EMERGENCY SERVICES RESPONDERS HAVE ARRIVED THE PREMISES HAVE BEEN AIRED OUT AND ALARM REMAINS IN ITS NORMAL CONDITION 4 AFTER FOLLOWING STEPS 1 3 IF ALARM...

Страница 11: ...owed DO NOT install a CO Alarm near a hatch or porthole through which water could be spilled on the device DO NOT install in locations where temperature moisture and or ultraviolet light affect the op...

Страница 12: ...gth 6 Pan Head screws to secure Mounting Base Do not over tighten Drill appropriate size hole 0 38 9 5mm Max for wired models to accommodate the wires If using a connector on the wires a larger hole m...

Страница 13: ...ely 25 NOTE A UNIT THAT HAS BEEN DEACTIVATED WILL NOT BE ABLE TO BE INSTALLED ONTO THE MOUNTING PLATE After installation is complete attach one of the enclosed Warning stickers to the wall next to the...

Страница 14: ...terconnect Relay Series units Connect the wires of up to 10 units to each other Two White 18 GA wires are provided for connecting to equipment on the vessel Each unit can handle a maximum of 1 Amp 220...

Страница 15: ...unit can handle a maximum of 1 Amp 220V DC NOTE ILLUSTRATION ABOVE SHOWS ALL POSSIBLE WIRING OPTIONS FOR BATTERY UNITS REFER TO TEXT FOR WIRING CONNECTIONS REQUIRED FOR EACH MODEL NOTE PROTECTIVE COV...

Страница 16: ...te button until Green LED turns on and release The alarm will simulate 2 alarm cycles 2 sets of 4 Beeps 5 sec Silence between The Red LED will flash once every 5 seconds Marine Interconnect Relay Seri...

Страница 17: ...s directly for more information about CO safety and their equipment Nuisance Alarms Although the CO Alarm will detect only carbon monoxide in a normal environment studies have found that unusually hig...

Страница 18: ...reboy xintex com If due to extenuating circumstances a product is to be returned after approval it must be received in 100 new resalable condition Products stored by the buyer for more than 26 weeks m...

Страница 19: ...n of the product or any other incidental costs of removal and or installation of the product or any other incidental costs which may arise as a result of any defect in material or workmanship and e up...

Отзывы: