General Information 
 

DANGER: 

ACTUATION OF THIS DEVICE INDICATES THE PRESENCE OF CARBON MONOXIDE (CO) WHICH CAN 
BE FATAL.  THE SOURCE OF THE CO MAY BE AN APPLIANCE SUCH AS A FURNACE, A WOOD 
BURNING STOVE, A VEHICLE, A GENERATOR, OR OTHER COMBUSTION SOURCE.  EVACUATE THE 
PREMISES IMMEDIATELY.  CHECK THAT ALL PERSONS ARE ACCOUNTED FOR.  CALL THE NEAREST 
FIRE DEPARTMENT AND ASK THEM TO DETERMINE THE SOURCE OF CARBON MONOXIDE.  DO 
NOT REENTER PREMISES UNTIL IT HAS BEEN AIRED OUT AND THE PROBLEM IS CORRECTED! 

 

WARNING: 

TO REDUCE THE RISK OF CARBON MONOXIDE POISONING, TEST ALARM OPERATION WHEN NOT 
IN USE FOR 10 DAYS OR MORE. 
 
THIS CARBON MONOXIDE ALARM IS DESIGNED TO DETECT CARBON MONOXIDE (CO) GAS FROM 
ANY SOURCE OF COMBUSTION.  IT IS NOT DESIGNED TO DETECT SMOKE, FIRE OR ANY OTHER 
GAS, UNLESS THE PRODUCT HAS BEEN INVESTIGATED AND DETERMINED TO COMPLY WITH THE 
APPLICABLE REQUIREMENTS. 
 
THIS DEVICE IS DESIGNED TO PROTECT INDIVIDUALS FROM THE ACUTE EFFECTS OF CARBON 
MONOXIDE EXPOSURE.  IT WILL NOT FULLY SAFEGUARD INDIVIDUALS WITH SPECIFIC MEDICAL 
CONDITIONS.  IF IN DOUBT CONSULT A MEDICAL PRACTITIONER. 
 
ANY PERSON WITH MEDICAL PROBLEMS MAY CONSIDER USING WARNING DEVICES THAT 
PROVIDE AUDIBLE AND VISUAL SIGNALS FOR CARBON MONOXIDE CONCENTRATIONS LESS THAN 
30 PPM. 

 

CAUTION: 

INSTALLATION SHALL BE DONE BY QUALIFIED PERSONNEL AUTHORIZED TO DO SO BY THE 
AUTHORITIES HAVING JURISDICTION FOR THE PARTICULAR APPLICATION IN WHICH THE PRODUCT 
IS BEING USED.  ELECTRICAL WIRING SHALL BE IN ACCORDANCE WITH APPLICABLE CODES.  
IMPROPER WIRING MAY RENDER THE UNIT INOPERABLE, DAMAGE COMPONENTS, OR CAUSE A 
FIRE, AND WILL VOID ALL WARRANTIES. 

 

TO FUNCTION AS INTENDED, THE CO ALARM MUST BE CONNECTED TO A CORRECT POWER 
SOURCE, AND FOR MAXIMUM EFFECTIVENESS, BE POWERED AT ALL TIMES. 
 
THIS DEVICE SHALL NOT BE INSTALLED OR USED IN AIRCRAFT AND/OR RACING VEHICLES.  
FIREBOY-XINTEX RESERVES THE RIGHT TO CHANGE FEATURES WITHOUT NOTICE. 
 
THIS ALARM WILL ONLY INDICATE THE PRESENCE OF CARBON MONOXIDE GAS AT THE SENSOR.  
CARBON MONOXIDE GAS MAY BE PRESENT IN OTHER AREAS. 
 
 
 

Содержание CMD6-MB

Страница 1: ...nect Relay Black Housing CMD6 MD Marine 12 24V DC CMD6 MD B Marine 12 24V DC Black Housing CMD6 MDR Marine 12 24V DC Interconnect Relay CMD6 MDR B Marine 12 24V DC Interconnect Relay Black Housing Own...

Страница 2: ...lling the Mounting Base 12 Connecting Alarm to Mounting Base 13 Wiring Connections Marine 12 24V DC Units 14 Wiring Connections Marine Battery Units 15 Activating Fireboy Xintex Carbon Monoxide Alarm...

Страница 3: ...TO PROTECT INDIVIDUALS FROM THE ACUTE EFFECTS OF CARBON MONOXIDE EXPOSURE IT WILL NOT FULLY SAFEGUARD INDIVIDUALS WITH SPECIFIC MEDICAL CONDITIONS IF IN DOUBT CONSULT A MEDICAL PRACTITIONER ANY PERSO...

Страница 4: ...evices All of these produce large amounts of CO and should never be operated while occupants are sleeping A slight build up of carbon monoxide in the human body over several hours causes headaches nau...

Страница 5: ...ove situations Extended operation of un vented fuel burning devices range oven etc Temperature inversions that can trap exhaust gases near the ground Drug or alcohol use increases the effect of CO exp...

Страница 6: ...of propulsion and auxiliary generators frequently for possible leaks High concentrations of CO in your boat may originate from an adjacent boat Exhaust fumes from nearby boats may enter your boat thro...

Страница 7: ...as a replacement for ordinary precautions or periodic inspections of equipment NEVER rely on alarm systems to save your life common sense is still prudent and necessary The audible horn on the CO Alar...

Страница 8: ...9 32V DC Nominal Current Draw 40 F 40 C to 158 F 70 C 6mA Maximum Current Draw 40 F 40 C to 158 F 70 C 38mA 32V DC Operating Storage Temperature 22 F 30 C to 158 F 70 C Alarm Points Time Weighted Ave...

Страница 9: ...such as when docking or maneuvering The CO Alarm takes this all under consideration by totaling the quantity of CO detected over a period of time The CO Alarm is programmed to alarm at a COHb level of...

Страница 10: ...OR MOVE AWAY FROM THE OPEN DOOR WINDOW UNTIL EMERGENCY SERVICES RESPONDERS HAVE ARRIVED THE PREMISES HAVE BEEN AIRED OUT AND ALARM REMAINS IN ITS NORMAL CONDITION 4 AFTER FOLLOWING STEPS 1 3 IF ALARM...

Страница 11: ...owed DO NOT install a CO Alarm near a hatch or porthole through which water could be spilled on the device DO NOT install in locations where temperature moisture and or ultraviolet light affect the op...

Страница 12: ...gth 6 Pan Head screws to secure Mounting Base Do not over tighten Drill appropriate size hole 0 38 9 5mm Max for wired models to accommodate the wires If using a connector on the wires a larger hole m...

Страница 13: ...ely 25 NOTE A UNIT THAT HAS BEEN DEACTIVATED WILL NOT BE ABLE TO BE INSTALLED ONTO THE MOUNTING PLATE After installation is complete attach one of the enclosed Warning stickers to the wall next to the...

Страница 14: ...terconnect Relay Series units Connect the wires of up to 10 units to each other Two White 18 GA wires are provided for connecting to equipment on the vessel Each unit can handle a maximum of 1 Amp 220...

Страница 15: ...unit can handle a maximum of 1 Amp 220V DC NOTE ILLUSTRATION ABOVE SHOWS ALL POSSIBLE WIRING OPTIONS FOR BATTERY UNITS REFER TO TEXT FOR WIRING CONNECTIONS REQUIRED FOR EACH MODEL NOTE PROTECTIVE COV...

Страница 16: ...te button until Green LED turns on and release The alarm will simulate 2 alarm cycles 2 sets of 4 Beeps 5 sec Silence between The Red LED will flash once every 5 seconds Marine Interconnect Relay Seri...

Страница 17: ...s directly for more information about CO safety and their equipment Nuisance Alarms Although the CO Alarm will detect only carbon monoxide in a normal environment studies have found that unusually hig...

Страница 18: ...reboy xintex com If due to extenuating circumstances a product is to be returned after approval it must be received in 100 new resalable condition Products stored by the buyer for more than 26 weeks m...

Страница 19: ...n of the product or any other incidental costs of removal and or installation of the product or any other incidental costs which may arise as a result of any defect in material or workmanship and e up...

Отзывы: