Part Number

 

18160, F, 06/29/2021

 

 

Operation of Fireboy-Xintex Carbon Monoxide Alarm(s) Continued 
 

CAUTION: 

THE AUDIBLE ALARM CANNOT BE CHECKED BY THE INTERNAL CIRCUITRY AND THEREFORE THE CO 
ALARM SHOULD BE TESTED FREQUENTLY USING THE TEST BUTTON AND VERIFYING PROPER 
ALARM SEQUENCES AND OPERATION. 
 
Normal 
The Green LED will flash once every 180

 

seconds (3 minutes) while in normal operation. 

 

Alarm  
When the CO Alarm enters alarm, the Alarm indicator begins flashing red and the horn beeps 4 
times and pauses for 4-5 seconds in a repeat pattern.  This indicates that the COHb level has been 
reached. 
 

WARNING: 

ACTUATION OF YOUR CO ALARM INDICATES THE PRESENCE OF CARBON MONOXIDE (CO), WHICH 
CAN KILL YOU.  IF ALARM SOUNDS: 
 
IF UNIT ALARMS FOLLOW THE GUIDELINES BELOW: 

1.

 

OPERATE RESET/SILENCE BUTTON 

2.

 

CALL YOUR EMERGENCY SERVICES (FIRE DEPARTMENT OR 911). 

3.

 

IMMEDIATELY MOVE TO FRESH AIR 

 OUTDOORS OR BY AN OPEN DOOR/WINDOW.  

CHECK THAT ALL PERSONS ARE PRESENT.  DO NOT RE-ENTER THE PREMISES OR MOVE 
AWAY FROM THE OPEN DOOR/WINDOW UNTIL EMERGENCY SERVICES RESPONDERS 
HAVE ARRIVED, THE PREMISES HAVE BEEN AIRED OUT AND ALARM REMAINS IN ITS 
NORMAL CONDITION. 

4.

 

AFTER FOLLOWING STEPS 1-3, IF ALARM REACTIVATES WITHIN A 24-HOUR PERIOD, 
REPEAT STEPS 1-3 AND CALL A QUALIFIED APPLIANCE TECHNICIAN TO INVESTIGATE FOR 
SOURCES OF CO FROM FUEL BURNING EQUIPMENT AND APPLIANCES, AND INSPECT 
FOR PROPER OPERATION OF THE EQUIPMENT.  IF PROBLEMS ARE IDENTIFIED DURING 
THIS INSPECTION, HAVE THE EQUIPMENT SERVICED IMMEDIATELY.  NOTE ANY 
COMBUSTION EQUIPMENT NOT INSPECTED BY THE TECHNICIAN AND CONSULT THE 
MANUFACTURES' INSTRUCTIONS, OR CONTACT THE MANUFACTURERS DIRECTLY, FOR 
MORE INFORMATION ABOUT CO SAFETY AND THIS EQUIPMENT. 

Remote Alarm 
This indicates that another CO alarm that is interconnected is going into alarm.  If the unit in 
remote alarm detects a high enough level of CO to alarm, then it will change from remote alarm 
to alarm in the standard alarm pattern.  A remote alarm should be treated the same as a CO 
alarm. 

 

End-of-Life (EOL) 
Self-diagnostics to determine end of useful sensor life, approximately 84 months (7 years). 
Contact manufacturer for repair/replacement options. 
 

Содержание CMD6-MB

Страница 1: ...nect Relay Black Housing CMD6 MD Marine 12 24V DC CMD6 MD B Marine 12 24V DC Black Housing CMD6 MDR Marine 12 24V DC Interconnect Relay CMD6 MDR B Marine 12 24V DC Interconnect Relay Black Housing Own...

Страница 2: ...lling the Mounting Base 12 Connecting Alarm to Mounting Base 13 Wiring Connections Marine 12 24V DC Units 14 Wiring Connections Marine Battery Units 15 Activating Fireboy Xintex Carbon Monoxide Alarm...

Страница 3: ...TO PROTECT INDIVIDUALS FROM THE ACUTE EFFECTS OF CARBON MONOXIDE EXPOSURE IT WILL NOT FULLY SAFEGUARD INDIVIDUALS WITH SPECIFIC MEDICAL CONDITIONS IF IN DOUBT CONSULT A MEDICAL PRACTITIONER ANY PERSO...

Страница 4: ...evices All of these produce large amounts of CO and should never be operated while occupants are sleeping A slight build up of carbon monoxide in the human body over several hours causes headaches nau...

Страница 5: ...ove situations Extended operation of un vented fuel burning devices range oven etc Temperature inversions that can trap exhaust gases near the ground Drug or alcohol use increases the effect of CO exp...

Страница 6: ...of propulsion and auxiliary generators frequently for possible leaks High concentrations of CO in your boat may originate from an adjacent boat Exhaust fumes from nearby boats may enter your boat thro...

Страница 7: ...as a replacement for ordinary precautions or periodic inspections of equipment NEVER rely on alarm systems to save your life common sense is still prudent and necessary The audible horn on the CO Alar...

Страница 8: ...9 32V DC Nominal Current Draw 40 F 40 C to 158 F 70 C 6mA Maximum Current Draw 40 F 40 C to 158 F 70 C 38mA 32V DC Operating Storage Temperature 22 F 30 C to 158 F 70 C Alarm Points Time Weighted Ave...

Страница 9: ...such as when docking or maneuvering The CO Alarm takes this all under consideration by totaling the quantity of CO detected over a period of time The CO Alarm is programmed to alarm at a COHb level of...

Страница 10: ...OR MOVE AWAY FROM THE OPEN DOOR WINDOW UNTIL EMERGENCY SERVICES RESPONDERS HAVE ARRIVED THE PREMISES HAVE BEEN AIRED OUT AND ALARM REMAINS IN ITS NORMAL CONDITION 4 AFTER FOLLOWING STEPS 1 3 IF ALARM...

Страница 11: ...owed DO NOT install a CO Alarm near a hatch or porthole through which water could be spilled on the device DO NOT install in locations where temperature moisture and or ultraviolet light affect the op...

Страница 12: ...gth 6 Pan Head screws to secure Mounting Base Do not over tighten Drill appropriate size hole 0 38 9 5mm Max for wired models to accommodate the wires If using a connector on the wires a larger hole m...

Страница 13: ...ely 25 NOTE A UNIT THAT HAS BEEN DEACTIVATED WILL NOT BE ABLE TO BE INSTALLED ONTO THE MOUNTING PLATE After installation is complete attach one of the enclosed Warning stickers to the wall next to the...

Страница 14: ...terconnect Relay Series units Connect the wires of up to 10 units to each other Two White 18 GA wires are provided for connecting to equipment on the vessel Each unit can handle a maximum of 1 Amp 220...

Страница 15: ...unit can handle a maximum of 1 Amp 220V DC NOTE ILLUSTRATION ABOVE SHOWS ALL POSSIBLE WIRING OPTIONS FOR BATTERY UNITS REFER TO TEXT FOR WIRING CONNECTIONS REQUIRED FOR EACH MODEL NOTE PROTECTIVE COV...

Страница 16: ...te button until Green LED turns on and release The alarm will simulate 2 alarm cycles 2 sets of 4 Beeps 5 sec Silence between The Red LED will flash once every 5 seconds Marine Interconnect Relay Seri...

Страница 17: ...s directly for more information about CO safety and their equipment Nuisance Alarms Although the CO Alarm will detect only carbon monoxide in a normal environment studies have found that unusually hig...

Страница 18: ...reboy xintex com If due to extenuating circumstances a product is to be returned after approval it must be received in 100 new resalable condition Products stored by the buyer for more than 26 weeks m...

Страница 19: ...n of the product or any other incidental costs of removal and or installation of the product or any other incidental costs which may arise as a result of any defect in material or workmanship and e up...

Отзывы: