HealtH & safety InformatIon

tHIs ProduCt Has Been desIgned
to tHe folloWIng standards:

This equipment complies with the Low Voltage Directive
2006/95/eC & the eMC Directive 2004/108/eC.

emC - conformity  was  demonstrated  by  meeting  the                     
following standards:

eN 55014-1: 2006/a2: 2011: electromagnetic Compatibility - 
Requirements for Household appliances, electric Tools and 
Similar apparatus - Part 1: emission

eN 55014-2: 1997/a2: 2008: electromagnetic Compatibility 
- Requirements for Household appliances, electric Tools 
and Similar apparatus - Part 2: Immunity - Product Family 
Standard

eN 61000-3-2: 2009: electromagnetic Compatibility (eMC) 
Part 3-2: Limits - Limits for Harmonic Current emissions 
(equipment input current <16 a per phase)

eN 61000-3-3: 2008: electromagnetic Compatibility (eMC) 
Part 3-3: Limits - Limitation of Voltage Changes, Voltage 
Fluctuations  and  Flicker  in  Public  Low-voltage  Supply             
Systems (equipment with rated current <16 a per phase and 
not subject to conditional connection)

The installer should be aware of his/her responsibilities under 
the current, local Health and Safety at Work act. The interests 
of  safety  are  best  served  if  the  boiler  is  installed  and                  
commissioned by a competent, qualified engineer, OFTeC 
trained and registered. If not, a Building Notice is required in 
england & Wales. Other parts of the British Isles, including the 
Channel Islands, also require notification to building control.

Under the Consumer Protection act 1987 (UK), section 6 of 
the Health and Safety act 1974 (UK) and the Safety, Health 
and  Welfare  at  Work  act  2005  (ROI),  we  are  required  to           
provide information on substances hazardous to health.

InsulatIon and seals
Ceramic Fibre, alumino - Silicone Fibre material are used for 
boards, ropes and gaskets. Known hazards are that people 
may suffer reddening and itching of the skin. Fibre entering 
the eye will cause foreign body irritation. It may also cause 
irritation to the respiratory tract.

Precautions should be taken by people with a history of skin 
complaints  or  who  may  be  particularly  susceptible  to                  
irritation. High dust levels are only likely to arise following 
harsh abrasion. Suitable personal protective equipment 
should be worn where appropriate.

generally, normal handling and use will not give discomfort. 
Follow  good  hygiene  practices,  wash  hands  before                          
consuming food, drink or using the toilet.

First aid - medical attention should be sought following eye 
contact or prolonged reddening of the skin.

The small quantities of adhesives and sealants used in the 
product are cured. They present no known hazards when 
used in the manner for which they are intended.

safety

1.  Switch off all electrical and other ignition sources.
2.  Remove all contaminated clothing to safeguard against 

fire risk and skin damage. Wash affected skin thoroughly 

with soap and water and remove clothing to a safe well 

ventilated area and allow to air before cleaning.

3.  Contain and smother the spill using sand or other suitable 

oil absorbent media or non-combustible material.

4.  Do not allow fuel to escape into drains or water courses. 

If this happens, contact the relevant authorities in your 

area.

5.  Consult local authority about disposal of contaminated 

soil.

fuel sPIllage

fIrst aId

If fuel is accidentally swallowed:

* Seek medical attention immediately.

Do NOT induce vomiting.

If fuel is splashed into eyes:

* Wash out with running water for at least ten

minutes and seek medical attention.

safety -  conformity  was  demonstrated  by  meeting  the             
following standards:

eN60335-1: 2012: Household and Similar electrical appliances 
- Safety - Part 1: general Requirements

eN60335-2-102: 2006/a1: 2010: Household and Similar 
electrical appliances - Safety - Part 2-102: Particular 
Requirements for gas, Oil and Solid-fuel Burning appliances 
having electrical Connections

Safe use of Kerosene. These fuels give off a flammable 
vapour when heated moderately. Vapour ignites easily, burns 
intensely and may cause explosion. The vapour can follow 
along at ground level for considerable distances from open 
containers and spillages collecting as an explosive mixture in 
drains, cellars, etc.
Fuels remove natural oils and fats from the skin and this 
may cause irritation and cracking of skin. Barrier cream con-
taining lanolin is highly recommended together with good 
personal  hygiene  and  where  necessary  appropriate  personal                   
protection equipment (P.P.e.).
gas  oil  may  also  cause  irreversible  damage  to  health  on            
prolonged or repeated skin contact.
always store fuels in a properly constructed and labelled 
tank. always handle fuel in open air or well ventilated space 
away from sources of ignition and refrain from smoking.
always drain fuel using a proper fuel retriever, funnel or 
mechanical siphon. Never apply heat to a fuel tank, container 
or pipework. Never siphon fuel through tube by mouth. 
avoid inhaling fuel vapour as this can cause light headedness 
and seriously impair judgement.

Содержание silver Boilerhouse 15-20kW

Страница 1: ...g Boilers Technical Manual HEATING SOLUTIONS This manual must remain with the householder once installation is complete Working towards a greener planet Silverpac Slimline Silverpac Silver Boilerhouse...

Страница 2: ......

Страница 3: ...rpac 22 8 2 Slimline Silverpac 23 8 3 Silver Boilerhouse 24 8 4 Silver Utility 25 9 Wiring 9 1 Silverpac 26 9 2 Slimline Silverpac 27 9 3 Silver Boilerhouse 28 9 4 Silver Utility 29 10 Burner 30 11 Te...

Страница 4: ...let First Aid medical attention should be sought following eye contact or prolonged reddening of the skin The small quantities of adhesives and sealants used in the product are cured They present no k...

Страница 5: ...status lights not included in Silver Boilerhouse and Silverpac models Set at Max 80 C Set at Mid 70 C Set at Min 60 C Burner Lockout The boiler is factory fitted with a burner control box lockout safe...

Страница 6: ...12 A1 2014 BS EN 12831 2003 and the statutory requirements of the Building Regulations To ensure the highest standards of installation safety it is important that the boiler be installed in compliance...

Страница 7: ...g manuals and BS 7074 Part 1 EN 12828 2003 etc Please note following important points before commencing installation Installation Commissioning Boilers must be installed commissioned and serviced by a...

Страница 8: ...r the cleaning door This should be checked at regular intervals and cleaned during annual service The condensate line should be plastic and have a minimum diameter of 22mm dia have a fall from the boi...

Страница 9: ...re connecting the condensate pump Condensate PUMP kit is available as an optional extra Boiler Sealed Condensate Drain Condensate Drain Trap Lime Stone Chippings Free Draining Soil Soak Away 500mm Fig...

Страница 10: ...Cone Float Screw cap Seal Seal 1 Push screw cap into connector and screw onto socket 2 Place cone into frame and float into cone 3 Screw frame with cone and float into connector 5 Final assembly 4 Pus...

Страница 11: ...Q Q R Pressure Jet Location Appliance Burner Type Condensing UK ROI NI A Directly below an opening airbrick opening window etc 1000mm 600mm B Horizontally to an opening airbrick opening window etc 100...

Страница 12: ...to BS EN 303 1 5 Terminating positions must be at least 1 8m distant from an oil storage tank unless a wall with at least 30 minutes fire resistance and extending 300mm higher and wider than the oil s...

Страница 13: ...ired to ventilate and to avoid overheating in the boiler area OPEN FLUE BOILER IN ROOM BOILER COMPARTMENT VENTILATED FROM OUTSIDE BOILER COMPARTMENT VENTILATED FROM ADJOINING ROOM 55mm2 kW 55mm2 kW 55...

Страница 14: ...Balanced flue TOP mark Snorkel 1 Push the flap valve into the balanced flue air intake 2 Ensure that the flap valve is in the correct position 3 Push the snorkel hose over the flap valve and air inta...

Страница 15: ...LVERPAC SLIMLINE SILVERPAC FLUE Put the 90 flue terminal with the cone on the boiler Fix the guard plate to the boiler and then the guard to the boiler Heatpac boiler after installation Fig 1 Fig 2 Fi...

Страница 16: ...ate System 35 flexible liner suitable for condensing applications System 35 adaptor 500mm Adjustable length Boiler adaptor Condensing boiler Condensing boiler NOTE All brick chimney constructions must...

Страница 17: ...oil tight Soldered joints are not permissible Before connecting to the boiler always flush the complete oil supply line and ensure that oil supply is completely clean and free of any dirt or foreign m...

Страница 18: ...erly commissioned when first used u The boiler should be commissioned by an OFTEC registered or competent qualified engineer familiar with Firebird products u The installation certificate and the comm...

Страница 19: ...the chamber 3 Clean the inside of the boiler with a vacuum cleaner 4 Refit all the baffles and the condensate trap securely 5 System pressure should not exceed 2 bar at full operating temperature The...

Страница 20: ...S 7074 Part 1 BS 5449 OFTEC standards and all other relevant legislation Preset Pressure Relief Valve 2 bar Water Side Resistance 15 20kW 20 26kW 26 35kW Flow Rate To Give A Nominal Output At 10K Diff...

Страница 21: ...d all other relevant legislation Preset Pressure Relief Valve 2 bar Water Side Resistance Flow Rate To Give A Nominal Output At 10K Differential Flow Rate Measured 2135 kg h Waterside Resistance 0 18...

Страница 22: ...ive A Nominal Output At 10K Differential Flow Rate Measured 1642 kg h 2135 kg h 2874 kg h Waterside Resistance 0 18 mbar 0 18 mbar 0 18 mbar Flow Rate To Give A Nominal Output At 20K Differential Flow...

Страница 23: ...W Flow Rate To Give A Nominal Output At 10K Differential Flow Rate Measured 1642 kg h 2135 kg h 2874 kg h Waterside Resistance 0 18 mbar 0 18 mbar 0 18 mbar Flow Rate To Give A Nominal Output At 20K D...

Страница 24: ...1 Condensate hose 111537 111537 111537 9 1 Drain cock 111329 111329 111329 10 1 Heat deflector 210904 210904 210904 11 1 Flap valve adapter 114262 114262 114262 12 1 Flap valve 114192 114192 114192 13...

Страница 25: ...ket 111317 7 1 Condensate trap 112184 8 1 Condensate hose 111537 9 1 Drain cock 111329 10 1 Heat deflector 210904 11 1 Flap valve adapter 114262 12 1 Flap valve 114192 13 1 Flue kit 411482 14 1 Contro...

Страница 26: ...Flue gasket 112104 112104 112104 6 1 Stat pocket 111317 111317 111317 7 1 Condensate trap 112184 112184 112184 8 1 Condensate hose 111537 111537 111537 9 1 Drain cock 111329 111329 111329 10 1 Heat de...

Страница 27: ...317 111317 7 1 Condensate trap 112184 112184 112184 8 1 Condensate hose 111537 111537 111537 9 1 Drain cock 111329 111329 111329 10 1 Heat deflector 210904 210904 210904 11 1 Air hose 111902 111902 11...

Страница 28: ...hermostat Reset pin inside Screw off cover Temperture control dial Max 80 C Min 60 C IMIT dual thermostat Pump live Earth Neutral Permanent live Timed Switch live Neutral Earth Pump over run thermosta...

Страница 29: ...e provided for with terminal connections in the control panel Use heat resistant cable Protect supply with 5A fuse Power to burner High temperture limit thermostat Reset pin inside Screw off cover Tem...

Страница 30: ...ids and covers are properly replaced and secured correctly 4 A permanent power supply not timed should be available at boiler location This can be used for a frost thermostat and or an over heat therm...

Страница 31: ...h temperture limit thermostat Reset pin inside Screw off cover Temperture control dial Max 80 C Min 60 C IMIT dual thermostat L1 switch live Pump over run thermostat 87 C L2 remote lockout lamp Please...

Страница 32: ...Danfoss S H nozzles are a Diesel nozzle and have a tolerance of 15 when used with Kerosene KEROSENE SETTINGS FOR FIREBIRD BOILER RANGE USING RDB 2 2 BURNERS Variations in nozzle throughput flue type...

Страница 33: ...accordance with a instruction technical manuals b all relevant standards and codes of practice 4 An OFTEC registered or competent qualified engineer using the correct installation and test equipment...

Страница 34: ...ergy Consumption Sound Power Level kW GJ dB SILVERPAC 15 20kW A 20 92 50 N A 20 26kW A 26 92 72 N A 26 35kW A 35 92 95 N A SLIMLINE SILVERPAC 20 26kW A 26 92 72 N A SILVER BOILERHOUSE 15 20kW A 20 92...