background image

5

be between 150mm and 300mm below the 

ceiling, and at least 300mm from a wall 

Smoke alarms should be positioned at no 

more than 600mm vertically below the 

highest point in the room 

LOUNGE

CELLAR

BEDROOM

BEDROOM

HALL

DINING ROOM

MINIMUM RECOMMENDATIONS

EXISTING HOMES

NOTE:

 Kitchens should be covered by a self 

contained heat detector.

RECOMMENDED FOR ADDITIONAL PROTECTION

300mm

150mm

150mm

600mm

300mm

detection system only  It cannot be used 

as a substitute for a hard wired system as 

required in new build properties  In this 

type of property the building regulations 

require alarms to be interlinked  You can 

obtain further information from your local 

fire service or building control department 

at your local council offices  These sources 

generally provide advice on new builds or 

projects that require planning permission 

Your smoke alarm typically meets the 

minimum requirements for family living 

units in existing buildings, as long as at 

least one unit is installed on each floor/
level of your property 

In order to achieve the earliest fire warning, 

we recommend that a smoke alarm is fitted in 

all rooms where the temperature is normally 

between 4°C (40°F) and 38°C (100°F)  

This alarm is particularly useful for 

locations such as stairs and exit routes 

where the Escape Light will illuminate 

your escape route 

WARNING:

  The alarm positions shown 

are based on typical homes  Construction 

and layout of individual dwellings will 

vary, so this should be regarded only as a 

guide  Check with your local fire station for 
further guidance 

Smoke alarms should be sited at least 

300mm from light fittings and walls  

Ideally as central as possible in the room  

If positioning your smoke alarm on the 

wall, the top of the detection element must 

Содержание THERMOPTEK ST-623E

Страница 1: ...User Manual Smoke Alarm with Escape Light Model ST 623E ...

Страница 2: ...dial 1 800 523171 Email technicalsupport sprue com Web www fireangel co uk GN4590R1 ST 623E Sprue Safety Products Ltd Vanguard Centre Coventry CV4 7EZ UK A Sprue Brand 0086 CPR 676744 EN 14604 2005 AC 2008 Smoke Alarm Device DoP SAFLDOP ST 623E 01 18 BS EN 14604 2005 AC 2008 KM 676743 ...

Страница 3: ...larm 6 Battery replacement 8 Note This user manual is also available in large text and other formats Please email technicalsupport sprue com or call 0800 141 2561 for further information Alarm test 9 Alarm Smart Silence 9 Sleep Easy 11 Maintenance 11 Troubleshooting 12 Disposal 14 Warranty 14 CONTENTS ...

Страница 4: ...you are installing this smoke alarm for use by others you must leave this manual with the end user THERMOPTEK MULTI SENSOR TECHNOLOGY Thermoptek alarms are toast proof meaning they can be positioned in areas close to kitchens that may be affected by cooking fumes Heat alarms should be used in kitchens where required This combines an optical sensing chamber with thermal enhancement The alarm is eff...

Страница 5: ...e on new builds or projects that require planning permission Your smoke alarm typically meets the minimum requirements for family living units in existing buildings as long as at least one unit is installed on each floor level of your property In order to achieve the earliest fire warning we recommend that a smoke alarm is fitted in all rooms where the temperature is normally between 4 C 40 F and ...

Страница 6: ...n common areas may not provide sufficient fire warning to residents or meet regulatory requirements This smoke alarm is designed to operate as a standalone smoke alarm WARNING This smoke alarm will not communicate with other smoke alarms or fire alarm systems It is not intended as a substitute for a complete alarm system Mobile Homes and Caravans This smoke alarm is suitable for use in mobile home...

Страница 7: ...Base Plate Use the fixing holes on the base plate as a guide when marking the position of the drill holes With an appropriately sized drill drill the holes and insert the plastic fixing anchors supplied if needed Fit the base plate to the ceiling or wall using the screws provided Base Plate Holes 3 FitYour Smoke Alarm Hold the alarm up to the base plate and push and rotate the alarm clockwise into...

Страница 8: ...ly the following batteries can be used for replacement Use of a battery other than those recommended below may have a detrimental effect on the alarm s operation AA Alkaline type Energizer E91 Duracell MN1500 Panasonic ProPower LR6 Remove the alarm from its base plate by turning anti clockwise and pulling gently Remove the existing batteries and replace with new batteries from the recommended list...

Страница 9: ... smoke alarm fails to give an audible test signal please refer immediately to Troubleshooting at the end of this manual ALARM SMART SILENCE DANGER If your smoke alarm emits the full alarm signal and you are not testing the unit the smoke alarm is warning you of a potentially dangerous situation that requires your immediate attention Only use the alarm silence function after making sure that there ...

Страница 10: ...alarm silence will be overridden meaning the alarm will continue to sound and the Escape Light will continue to illuminate the event of a known false alarm your smoke alarm can be temporarily silenced by pressing the central test button Your alarm will automatically return to full sensitivity within 10 minutes a Briefly press and release the test button The alarm sound will stop and the Escape Lig...

Страница 11: ...y to ensure protection in the event of a fire MAINTENANCE Your smoke alarm has been designed to be as maintenance free as possible however there are several things you must do to keep it working properly Testing Test your smoke alarm once every week see AlarmTest Any test failures should be reported to theTechnical SupportTeam Cleaning As a minimum your smoke alarm should be cleaned once every 3 m...

Страница 12: ...sitivity mode it may not test Wait 15 minutes then try again If the alarm has been recently fitted and still fails to self test then contact Technical Support Your smoke alarm chirps intermittently Check the location of your smoke alarm see Positioning Check that your smoke alarm is definitely the source of chirping make sure the noise isn t coming from another alarm by process of elimination Your...

Страница 13: ...u experience frequent unwanted alarms Check the location of your smoke alarm see Positioning Clean the smoke alarm see Maintenance If the frequent unwanted alarms continue contact Technical Support for advice The Escape Light does not illuminate when unit is in alarm If the Escape Light does not illuminate at all when testing or when the unit is in full alarm then contact Technical Support If you ...

Страница 14: ...e disposed of with your other household waste This alarm is ideally suited for disposal within the waste electronic and electrical equipment WEEE recycling scheme Please recycle where facilities exist Check with your local authority retailer or contact our technical support team for recycling disposal advice as regional variations apply Once the batteries are removed the low battery warning chirp ...

Страница 15: ...15 ...

Страница 16: ......