5
be between 150mm and 300mm below the
ceiling, and at least 300mm from a wall
Smoke alarms should be positioned at no
more than 600mm vertically below the
highest point in the room
LOUNGE
CELLAR
BEDROOM
BEDROOM
HALL
DINING ROOM
MINIMUM RECOMMENDATIONS
EXISTING HOMES
NOTE:
Kitchens should be covered by a self
contained heat detector.
RECOMMENDED FOR ADDITIONAL PROTECTION
300mm
150mm
150mm
600mm
300mm
detection system only It cannot be used
as a substitute for a hard wired system as
required in new build properties In this
type of property the building regulations
require alarms to be interlinked You can
obtain further information from your local
fire service or building control department
at your local council offices These sources
generally provide advice on new builds or
projects that require planning permission
Your smoke alarm typically meets the
minimum requirements for family living
units in existing buildings, as long as at
least one unit is installed on each floor/
level of your property
In order to achieve the earliest fire warning,
we recommend that a smoke alarm is fitted in
all rooms where the temperature is normally
between 4°C (40°F) and 38°C (100°F)
This alarm is particularly useful for
locations such as stairs and exit routes
where the Escape Light will illuminate
your escape route
WARNING:
The alarm positions shown
are based on typical homes Construction
and layout of individual dwellings will
vary, so this should be regarded only as a
guide Check with your local fire station for
further guidance
Smoke alarms should be sited at least
300mm from light fittings and walls
Ideally as central as possible in the room
If positioning your smoke alarm on the
wall, the top of the detection element must