background image

14

available or in stock  This warranty applies to the 
original retail purchaser from the date of original 
retail purchase and is not transferable  Proof of 
purchase is required 

This warranty does not cover damage resulting 
from accident, misuse, disassembly, abuse or lack 
of reasonable care of the product, or applications 
not in accordance with the user manual  It does 
not cover events and conditions outside of Sprue 
Safety Products Ltd’s control, such as Acts of God 
(fire, severe weather etc )  It does not apply to 
retail stores, service centres or any distributors 
or agents  Sprue Safety Products Ltd will not 
recognise any changes to this warranty by third 
parties 

Sprue Safety Products Ltd shall not be liable 
for any incidental or consequential damages 
caused by the breach of any expressed or 
implied warranty  Except to the extent prohibited 
by applicable law, any implied warranty of 
merchantability or fitness for a particular purpose 
is limited in duration for 5 (five) years 

This warranty does not affect your statutory 
rights  Except for death or personal injury, Sprue 
Safety Products Ltd shall not be liable for any loss 
of use, damage, cost or expense relating to this 
product or for any indirect, or consequential loss, 
damages or costs incurred by you or any other 
user of this product 

DISPOSAL

Waste electrical products should not be disposed 
of with your other household waste  This alarm 
is ideally suited for disposal within the waste 
electronic and electrical equipment (WEEE) 
recycling scheme 

Please recycle where facilities exist  Check with 
your local authority, retailer or contact our 
technical support team for recycling/disposal 
advice as regional variations apply 

Once the batteries are removed, the low battery 
warning chirp will stop   The batteries should 
always be removed before disposal 

WARNING:

 Do not attempt to open  Do not burn 

WARRANTY

Sprue Safety Products Ltd warrants to the 
original purchaser that its enclosed smoke 
alarm be free from defects in materials and 
workmanship under normal residential use and 
service for a period of 5 (five) years from the date 
of purchase  This warranty does not cover the 
batteries which are considered user-replaceable 
parts  Provided the product is sent back to Sprue 
Safety products with proof and date of  purchase, 
Sprue Safety Products Ltd hereby warrants that 
during the 5 (five) year period commencing from 
the date of purchase Sprue Safety Products Ltd, 
at its discretion, agrees to replace the unit free 
of charge  The warranty on any replacement 
ST-623E alarm, will last for the remainder of 
the period of the original warranty in respect 
of the alarm originally purchased – that is from 
the date of original purchase and not from the 
date of receipt of the replacement product  
Sprue Safety Products Ltd reserves the right 
to offer an alternative product similar to that 
being replaced if the original model is no longer 

Содержание THERMOPTEK ST-623E

Страница 1: ...User Manual Smoke Alarm with Escape Light Model ST 623E ...

Страница 2: ...dial 1 800 523171 Email technicalsupport sprue com Web www fireangel co uk GN4590R1 ST 623E Sprue Safety Products Ltd Vanguard Centre Coventry CV4 7EZ UK A Sprue Brand 0086 CPR 676744 EN 14604 2005 AC 2008 Smoke Alarm Device DoP SAFLDOP ST 623E 01 18 BS EN 14604 2005 AC 2008 KM 676743 ...

Страница 3: ...larm 6 Battery replacement 8 Note This user manual is also available in large text and other formats Please email technicalsupport sprue com or call 0800 141 2561 for further information Alarm test 9 Alarm Smart Silence 9 Sleep Easy 11 Maintenance 11 Troubleshooting 12 Disposal 14 Warranty 14 CONTENTS ...

Страница 4: ...you are installing this smoke alarm for use by others you must leave this manual with the end user THERMOPTEK MULTI SENSOR TECHNOLOGY Thermoptek alarms are toast proof meaning they can be positioned in areas close to kitchens that may be affected by cooking fumes Heat alarms should be used in kitchens where required This combines an optical sensing chamber with thermal enhancement The alarm is eff...

Страница 5: ...e on new builds or projects that require planning permission Your smoke alarm typically meets the minimum requirements for family living units in existing buildings as long as at least one unit is installed on each floor level of your property In order to achieve the earliest fire warning we recommend that a smoke alarm is fitted in all rooms where the temperature is normally between 4 C 40 F and ...

Страница 6: ...n common areas may not provide sufficient fire warning to residents or meet regulatory requirements This smoke alarm is designed to operate as a standalone smoke alarm WARNING This smoke alarm will not communicate with other smoke alarms or fire alarm systems It is not intended as a substitute for a complete alarm system Mobile Homes and Caravans This smoke alarm is suitable for use in mobile home...

Страница 7: ...Base Plate Use the fixing holes on the base plate as a guide when marking the position of the drill holes With an appropriately sized drill drill the holes and insert the plastic fixing anchors supplied if needed Fit the base plate to the ceiling or wall using the screws provided Base Plate Holes 3 FitYour Smoke Alarm Hold the alarm up to the base plate and push and rotate the alarm clockwise into...

Страница 8: ...ly the following batteries can be used for replacement Use of a battery other than those recommended below may have a detrimental effect on the alarm s operation AA Alkaline type Energizer E91 Duracell MN1500 Panasonic ProPower LR6 Remove the alarm from its base plate by turning anti clockwise and pulling gently Remove the existing batteries and replace with new batteries from the recommended list...

Страница 9: ... smoke alarm fails to give an audible test signal please refer immediately to Troubleshooting at the end of this manual ALARM SMART SILENCE DANGER If your smoke alarm emits the full alarm signal and you are not testing the unit the smoke alarm is warning you of a potentially dangerous situation that requires your immediate attention Only use the alarm silence function after making sure that there ...

Страница 10: ...alarm silence will be overridden meaning the alarm will continue to sound and the Escape Light will continue to illuminate the event of a known false alarm your smoke alarm can be temporarily silenced by pressing the central test button Your alarm will automatically return to full sensitivity within 10 minutes a Briefly press and release the test button The alarm sound will stop and the Escape Lig...

Страница 11: ...y to ensure protection in the event of a fire MAINTENANCE Your smoke alarm has been designed to be as maintenance free as possible however there are several things you must do to keep it working properly Testing Test your smoke alarm once every week see AlarmTest Any test failures should be reported to theTechnical SupportTeam Cleaning As a minimum your smoke alarm should be cleaned once every 3 m...

Страница 12: ...sitivity mode it may not test Wait 15 minutes then try again If the alarm has been recently fitted and still fails to self test then contact Technical Support Your smoke alarm chirps intermittently Check the location of your smoke alarm see Positioning Check that your smoke alarm is definitely the source of chirping make sure the noise isn t coming from another alarm by process of elimination Your...

Страница 13: ...u experience frequent unwanted alarms Check the location of your smoke alarm see Positioning Clean the smoke alarm see Maintenance If the frequent unwanted alarms continue contact Technical Support for advice The Escape Light does not illuminate when unit is in alarm If the Escape Light does not illuminate at all when testing or when the unit is in full alarm then contact Technical Support If you ...

Страница 14: ...e disposed of with your other household waste This alarm is ideally suited for disposal within the waste electronic and electrical equipment WEEE recycling scheme Please recycle where facilities exist Check with your local authority retailer or contact our technical support team for recycling disposal advice as regional variations apply Once the batteries are removed the low battery warning chirp ...

Страница 15: ...15 ...

Страница 16: ......

Отзывы: