Remove Shipping Disablement Ribbon

Warning

Your FireAngel has been shipped in a disabled state. You must completely remove the shipping disablement ribbon
before use. Failure to remove the ribbon will render the FireAngel inoperative in the event of a fire emergency

Note: Your fireangel may beep or start chirping once a minute on removal of shipping disablement ribbon. This is normal, read on for clarification.

2.

Locate Suitable Lighting Fixture

Important

Your FireAngel requires a mains supply of electricity to recharge the integral battery. Only install in suitable light fittings
that are used regularly. Your FireAngel requires the light to be switched on for a total of 1 hour per week to remain in
its fully charged state.

Please ensure your home’s electrical wiring is in accordance with BS7671.

a)

Orientation

Your FireAngel is only intended to operate with the bulb 
underneath. Under no circumstances should your FireAngel
be installed upside down.

HOW TO INSTALL YOUR FIREANGEL

1. Hold FireAngel

3. Pull out from base 

of alarm

2. Unplug ribbon

connector

4. Remove ribbon from 

FireAngel & retain 
(see page 20)

Содержание PS-101

Страница 1: ...PS 101 User Manual Plug In Smoke Alarm 10Year Life...

Страница 2: ...l type lampshades 7 b Uplighter type lampshades 8 9 4 Fully charge your FireAngel 10 5 Test your FireAngel 10 Page Operation 11 Low battery Condition 11 Alarm test 11 Alarm silence 12 Routine Maintena...

Страница 3: ...latest additions to our product range and futher technical information This user manual contains important information regarding the operation of your FireAngel Smoke Alarm If you are installing this...

Страница 4: ...eep have individual Smoke Alarms To avoid false alarms Smoke Alarms should not be located in Areas where combustion particles may be present such as garages In areas where air flows may carry combusti...

Страница 5: ...capacity from a low battery alarm condition after 8 hours You can continue to charge beyond 8 hours however Smoke Alarms are designed to alert you with an audible alarm at a distance specified within...

Страница 6: ...tant Your FireAngel requires a mains supply of electricity to recharge the integral battery Only install in suitable light fittings that are used regularly Your FireAngel requires the light to be swit...

Страница 7: ...y c Lampshade Your FireAngel is only intended for installation within lampshades that allow the flow of air around and through the Alarm This usually means that the lampshade is open at both ends The...

Страница 8: ...ly reduce the life span of your FireAngel and invalidate your warranty 3 Install Your FireAngel a Conventional type lampshades Ensure the selected light fitting is switched off and that the bulb is co...

Страница 9: ...rom the light fitting a Remove the lampshade fixing skirt to allow the removal of the lampshade Note care must be taken to avoid the lampshade falling c Fit your FireAngel into the light fitting b Pla...

Страница 10: ...e are not wide enough apart to allow installation simply ease apart until your FireAngel can be fitted Important Your FireAngel has been designed to fit into modern light fixtures that use an average...

Страница 11: ...o give an audible test signal please refer immediately to the troubleshooting guide on page 15 of this manual If your FireAngel starts chirping once per minute then you have flicked the lightswitch to...

Страница 12: ...is occurs you must restore the mains supply to the unit switch the light on within 8 hours to maintain correct operation Following restoration of the mains supply the FireAngel batteries will recharge...

Страница 13: ...ediate attention Only use the alarm silence function after making sure that there is no ongoing fire emergency situation NOTE Your FireAngel is suitable for use with dimmer switches NOTE During strong...

Страница 14: ...nce free as possible and although the unit requires NO battery maintenance for its entire life there are several things you must do to keep it working properly Attention Your FireAngel is a sealed mai...

Страница 15: ...ficult to ascertain if the electrical supply is turned off Under no circumstances should you place your fingers in the aperture provided to fit the light bulb in the base of the alarm Failure to compl...

Страница 16: ...n of your FireAngel see Application Positioning Fully charge your FireAngel see Installation section 4 Test your FireAngel see Installation section 5 Clean your FireAngel see Routine Maintenance Check...

Страница 17: ...lect anything or to get dressed Feel the doors to see if they are hot If they are not open them carefully Do not open a door if it is hot Use an alternate escape route Stay close to the floor Smoke an...

Страница 18: ...ely if they are not working properly 3 Follow fire safety rules and prevent hazardous situations Use smoking materials properly Never smoke in bed Keep matches and cigarette lighters away from childre...

Страница 19: ...loor crawl if necessary Show them how to use the alternate exit if the door is hot and should not be opened Decide on a meeting place a safe distance from your house Make sure that all your children u...

Страница 20: ...s not in accordance with the user manual This Warranty does not effect your statutory rights Returns We recommend that you contact the FireAngel Technical Support Line in the first instance on 024 762...

Страница 21: ...TES For instructions on how to refit the shipping disablement ribbon for transportation or storage please see our website www fireangel co uk or call the technical support line see page 15 Tape ribbon...

Страница 22: ...ntre Puma Way Coventry CV1 2TT England Technical Support Line 024 7623 6663 1 800 523171 in Eire E mail technicalsupport fireangel co uk Web www fireangel co uk Ref SA0137 R5 Conforms to BS 5446 1 200...