9
FIPALIFT Smart
Step 1:
Cut the lifting tube to length and cut away the wire coil.
Step 2:
Cut away any excess material and orange-coloured adhesive tape. If you proceed as shown in
the figure, the wire coil will not come away from the material.
Step 3:
Remove about 20 mm of orange-coloured adhesive tape from the wire coil.
Step 4:
Remove about 2 turns of the white cord from the cut ends.
Step 5:
Screw the lifting tube back onto the plastic adapter.
Step 6:
Then wind reinforced adhesive tape (FIPA item number SH.SPP.ALL.0034) around the lifting
tube and the plastic adapter. The adhesive tape must be tightly tensioned.
Step 7:
Pull the protective cover back over the tube.
Selecting the vacuum pump
The selection is highly dependent on the consistency of the load to be lifted; lifting trials may be
required. For the correct design, please contact our Technical Sales Department (+49 89 962489-0).
The pumps are not included in the delivery and must be ordered separately.
The following pumps are available from FIPA and are approved for the FIPALIFT Smart tube lifter:
Technical data
Item no.
DT.25B-1
DT.25B-3
Suction power at 50 Hz
[m
3
/h]
25
25
Suction power at 60 Hz
[m
3
/h]
29
29
Final vacuum
[%]
88
88
Power supply at 50 (60) Hz
[V]
220 - 240
Delta: 220-255 (220-266)
Star: 380-440 (380-460)
Current consumption at 50 (60) Hz
[A]
5.8 (6.2)
Delta: 3.8-4.2 (4.4-4.2)
Star: 2.2-2.4 (2.5-2.4)
Rated power at 50 Hz
[kW]
0.75
0.75
Rated power at 60 Hz
[kW]
0.9
0.9
Noise level at 50 Hz
[dB(A)]
65
65
Noise level at 60 Hz
[dB(A)]
67
67
Operating temperature at 50 Hz
[°C]
65 - 70
65 - 70
Operating temperature at 60 Hz
[°C]
70 - 75
70 - 75
Weight
[kg]
29
28.5
Accessories
Spare part kit KIT-DT.25B*