FIPALIFT Smart
10
Technical data
Item no.
DT.40B-1
DT.40B-3
DT.60C-3
Suction power at 50 Hz
[m
3
/h]
40
40
60
Suction power at 60 Hz
[m
3
/h]
46
46
70
Final vacuum
[%]
88
88
88
Power supply at 50 (60) Hz
[V]
220 - 240
Delta: 220-255 (220-266)
Star: 380-440 (380-460)
Delta: 230 (265)
Star: 400 (460)
Current consumption at 50 (60) Hz
[A]
9.8 (9)
Delta: 7 (7.1-7)
Star: 4 (4.1-4.0)
Delta: 5.91 (5.6)
Star: 3.4 (3.23)
Rated power at 50 Hz
[kW]
1.5
1.5
1.5
Rated power at 60 Hz
[kW]
1.8
1.8
1.8
Noise level at 50 Hz
[dB(A)]
68
68
70
Noise level at 60 Hz
[dB(A)]
70
70
72
Operating temperature at 50 Hz
[°C]
75 - 80
75 - 80
70 - 73
Operating temperature at 60 Hz
[°C]
80 - 85
80 - 85
72 - 75
Weight
[kg]
40
37.5
66
Accessories
Spare part kit KIT-DT.40B*
Spare part kit KIT-DT.60C
Diagrams
>
Suction power depending on vacuum level at 50 Hz
>
Suction power depending on vacuum level at 60 Hz
Sucon power
[m
3
/h
]
100
80
60
40
20
0
Vacuum level
[%]
DT.60
90
50
70
30
10
0
DT.25
DT.40
Sucon power
[m
3
/h
]
100
80
60
40
20
0
DT.60
Vacuum level
[%]
90
50
70
30
10
0
DT.25
DT.40
Installation of the electrical vacuum pump
>
The vacuum pump must be positioned as close as possible to the lifting unit in order to keep
the length of the vacuum hose as short as possible. If the FIPALIFT Smart tube lifter is intended
to lift loads as quickly as possible, it is especially important that the vacuum hose between the
vacuum pump and the lifting unit is not too long. A longer vacuum hose reduces the possibili-
ties of the lifting unit utilising the full capacity of the vacuum pump. It is recommended that
the hose between vacuum pump and lifting unit is not longer than 30 m. If a longer hose is
necessary, please contact our Technical Sales Department.