MAINTENANCE
TERMINATOR-1000
Rev. 000
20/12/04
28/35
5. MAINTENANCE
5.1. PERIODICAL
MAINTENANCE
A periodical maintenance is very important.
Please write down in the format you find below all the interventions done on the machine.
•
Trained personnel only can service the machine and especially electric and electromechanical
parts by means of suitable tools and equipments.
•
Make reference to FIORENTINI S.r.l. only for service and spare parts (§ 7.1. and § 7.2.).
OPERATION
INTERVENTION
HOW OFTEN
Clean the recovery tank and the oil filter of the
suction motor
•
Do not use corrosive substances.
•
Do not use bolts of water.
Every day
Cleaning
¾
Check the suction pipes and the squeegee
Every week
¾
Check the rubber suction blades of the
squeegee
¾
Check the water battery level
Every 15 days
Check the filter of the clean water tank
Every month
Check and regulate the breaking system
Every 3 months
Check the connection of the battery cables
Every 6 months
Check the brushes of each motor
Every year
Check up
¾
Check the safety devices
¾
Check the electric system
Every year
5.2 BATTERIES
MAINTENANCE
The operator has to check the batteries charge when the machine is on duty by means of the indicator on the
dashboard, which shows:
¾
Green light: charged battery
¾
Yellow light: slightly charged battery
¾
Red light: uncharged battery
The operator must keep the battery room open during the batteries recharge. Moreover:
¾
It is forbidden to use flames and/or to smoke near the batteries;
¾
Pay attention to the battery acid;
¾
Do not develop sparks near the batteries;
¾
Pay attention to the batteries gazes, which can burst;
¾
Do not invert battery polarities.