MAINTENANCE
DELUXE 55-60
Rev. 00 del 05/07/04
32/36
5.4 ELECTRICAL EQUIPMENT CHECKING
The electrical system must be checked every two years. Possible defects, such as connections off and burnt
cables, must be suddenly replaced.
All intervention on the electrical system must be done by a technician.
All maintenance or repair out of the ordinary maintenance must be done with personnel
authorized only by FIORENTINI.
5.5 TABEL ABOUT TESTS TO BE CARRIED OUT
RECURRENCE
OPERATOR
CONTROLS
SAFETY DISPOSITIVES
2 YEARS
PROFESSIONAL TECHNICIAN
ELECTRICAL SYSTEM
2 YEARS
FIORENTINI TECHNICIAN
BRAKING SYSTEM
3 MONTHS
PROFESSIONAL TECHNICIAN
COMPLETE CHECKUP
5 YEARS
FIORENTINI TECHNICIAN
MAINTENANCE
RECOVERY TANK CLEANING
DAILY
OPERATOR
SUCTION MOTOR FILTER
DAILY
OPERATOR
SOLUTION TANK FILTER
MONTHLY
OPERATOR
SUCTION PIPES CLEANING
WEEKLY
OPERATOR
SQUEEGEE CLEANING
WEEKLY
OPERATOR
BLADES LEVEL CONTROL
WEEKLY
OPERATOR
WATER BATTERY LEVEL
WEEKLY
OPERATOR
BATTERY CABLES CONTROL
6 MONTHS
PROFESSIONAL TECHNICIAN
MOTOR BRUSHES CONTROL
EVERY YEAR
PROFESSIONAL TECHNICIAN