35
6
ELECTRICAL SAFETY FUSES
The equipment is supplied with safety fuses (6.3X32) of 10A or 15A (it
depends on the model) against electric shocks, over-currents and short
circuits.
Opening the door, the fuses are behind the frontal panel. Using a
screwdriver unscrew the fuses’ case and in case of failure substitute them.
7
DMLP TOUCH DIGITAL MONITOR
Introduction
The equipment can be supplied with DMLP Touch Digital Monitor. This instrument is
completely independent from the ECT-F touch controller. It records independently
temperatures
– by means of a PT100 probe – and signals temperature alarms or power
failures (using a back-up battery supplied as standard automatically recharged).
Safety is at the highest levels with alarms for High and Low temperatures power failure, door
open and diagnostic tests.
Thanks to the buffer battery, the temperature record is guaranteed up to 12 hours also in
case of power failure.
The DMLP Digital Monitor has as standard no. 2 dry contacts.
Please refer to Par. 8.5 for more information on buffer batteries maintenance and
usage.
8
ORDINARY AND PROGRAMMED MAINTENANCE
The information in this section is addressed to the end users, either as non-specialized
personnel or as ordinary maintenance worker.
8.1
PROHIBITION OF SAFETY DEVICES REMOVAL
Before removing guards, switch off the equipment and disconnect it from the mains.
Manufacturer and distributor disclaim all liability that may arise if this regulation is not
observed.
8.2
CLEANING OF THE EQUIPMENT INSIDE AND OUTSIDE
The appliance is thoroughly cleaned in our factory before delivery. We recommend, however,
that you clean the interior of the appliance before use. Before any cleaning operation, make
sure that the appliance power cord is disconnected. Also we suggest cleaning both the
interior and the exterior surfaces of the appliance at least twice a year.
For more details see the below paragraph:
- Cleaning products: water and non-abrasive neutral detergent. DO NOT USE SOLVENT
OR THINNERS
- Cleaning method: use a cloth or sponge soaked in a suitable cleaning product to clean the
interior and exterior parts of the cabinet
- Disinfection: do not use substances that could alter the basic characteristics of the stored
material
- Rinsing: use a cloth or sponge soaked in clean water. DO NOT USE WATER JETS
- Frequency: at least twice a year or at different intervals in accordance with the type of
pharmaceutical products stored
- TFT touch screen and ECT-F display must be cleaned with a water moistened cloth.
In freezers (-20°C) with glass door model Vision, the door has to be cleaned with a
water drained cloth. Do not use chemical products.