1
1
AF1
MEGA SD - Cod.197DD8100
GB
START-Up AND OpERATION
1 - CHECKS TO BE CArrIED OUT PrIOr TO STArT-UP
N.B.: The customer is responsible for installing the machine and making the required electrical and air connections.
Initial system start-up must be carried out by skilled personnel who will make the various checks required and follow
the respective instructions.
Each machine was thoroughly tested at the plant before shipping.
You should monitor the compressor during the first hours of operations to check for faults.
• Follow the installation prescriptions given in the previous chapters.
• Remove all packaging materials and tools.
• Connect the compressor to the distribution line as shown in paragraphs 6.2 and 6.3.
• Check the oil level in the tank: refer to section “Maintenance, oil control and topping up.” In the event of low oil level, top up
with rot-energy plus.
• Check for correspondence between the compressor plate data with the actual specifications of the electrical system.
A variation of ± 10% with respect to the rated value is allowed.
• Connect the machine to the electrical system as described in the previous chapters.
Compliance with the correct voltage phase sequence is
fundamental since this defines the direction of rotation of
the motor. The direction of rotation must be that indicated
by the adhesive labels located to the side of the screw unit
(see picture).
Note that even a few seconds of incorrect rotation may
cause serious damage.
A phase sequence checking device to prevent mistakes is
fitted in the electrical panel.
Before starting the machine read the following sections
and the chapter on maintenance operations for in-depth
knowledge of the machine.
2 - “NrG” CONTrOL PANEL
The compressor is fitted with a “control panel” for setting up and monitoring machine operation. The operating parameters
were entered by the Manufacturer during “testing”. The parameters were tested for several hours in the various operating
conditions.
The features offered by this electronic control system includes:
• Fully automatic compressor operation.
• real-time operating parameter display.
• Customization operating parameter.
•
Programming of compressor operation on a daily or weekly basis.
•
Programming and signalling of the Manufacturer’s maintenance schedule.
•
Machine self-protection system to signal fault pre-alarms and automatically stop the machine in the event of serious
problems.
•
Remote machine control.
•
Possibility of connecting the compressor via CAN-buS interface (optional) to other similar compressors for integrated management
of the set of machines.
•
Remote compressor monitoring via personal computer and dedicated software (optional).