Fimer TRIO-20.0-27.6-TL-OUTD-US Скачать руководство пользователя страница 8

FIMER_TRIO-20.0_27.6-TL-OUTD-US_Quick Installation Guide_EN_RevB

8

For more information 

please contact your 

local FIMER 

representative or visit:

fimer.com

We reserve the right to make technical changes or 

modify the contents of this document without prior notice. 

With regard to purchase orders, the agreed particulars 

shall prevail. FIMER does not accept any responsibility 

whatsoever for potential errors or possible lack of 

information in this document.

We reserve all rights in this document and in the 

subject matter and illustrations contained therein. Any 

reproduction, disclosure to third parties or utilization of 

its contents – in whole or in parts – is forbidden without 

prior written consent of FIMER. Copyright© 2021 FIMER. 

All rights reserved.

16-06-2021

16.  Characteristics and technical data

Technical Data

Values

TRIO-20.0-TL-OUTD

TRIO-27.6-TL-OUTD

Nominal Output Power

W

20000

27600

Maximum Output Power

W

22000*

30000*

Rated Grid AC Voltage

V

480

480

Number of Independent MPPT Channels

2

2

Maximum Usable Power for Each MPPT Channel

W

12000

16000

Absolute Maximum Voltage (Vmax)

V

1000

1000

Start- Up Voltage (Vstart)

V

360 (adj. 250-500)

360 (adj. 250-500)

Full Power MPPT Voltage Range

V

450-800

520-800

Operating MPPT Voltage Range

V

200-950

200-950

Maximum Usable Current (Idc max) for both MPPT in Parallel

A

50.0

61.8

Maximum Usable Current (Idc max) per MPPT Channel

A

25.0

30.9

Maximum Short Circuit Current (Isc max) per MPPT Channel

A

30.0

36.0

Max. Short Circuit Current (Isc max) for both MPPT in Parallel

A

60.0

72.0

Number of Wire Landing Terminals per MPPT Channel

-S version: 2, -S1, -S1A, -S1B version: 8

Array Wiring Termination Type

 -S version: Terminal Block, Screw Terminal, Copper Only 12AWG-2AWG,  

type B or C stranding 19 strand max per conductor 

S1, -S1A, -S1B version: Touch-safe fuse holder, Screw Terminal, Copper 

Only 12AWG-6AWG, type B or C stranding (19 strand max per conductor)

Grid Connection Type

3Ø/3W or 4W+Ground

3Ø/3W or 4W+Ground

Default Voltage Range

V

422-528

422-528

Adjustable Voltage Range

V

240-552

240-552

Nominal Grid Frequency

Hz

60

60

Adjustable Grid Frequency Range

Hz

57-63

57-63

Maximum Current (Iac max/phase)

ARMS

27.0

36.0

Power Factor

> 0.995

> 0.995

Total Harmonic Distortion At Rated Power

%

<3

<3

Grid Wiring Termination Type

Spring Tension Clamp Terminal, Copper wiring only,  6AWG-4AWG, type 

B or C stranding

(19 strand max per conductor)

Fault Current

ARMS

35.0

46.0

Reverse Polarity Protection

Yes.  Passive inverter protection only.**

Supplementary Over-Voltage Protection Type For Each MPPT

-S1, -S1A, -S1B versions only: Plug-in Class II Modular Surge Arrester

PV Array Ground Fault Detection

Meets UL1741/NEC 690.5 requirements

Anti-Islanding Protection

Meets UL1741/IEEE1547 requirements

Supplementary Over-Voltage Protection Type

-S1A version: Plug-in Class II Modular Surge Arrester

Maximum Efficiency

%

98.2

98.2

CEC Efficiency

%

97.5

97.5

Feed-In Power Threshold

WRMS

65

70

Stand-by Consumption

WRMS

<8

<8

User-Interface (Display)

5.5” x 1.25” Graphic Display

Standard Communication Interfaces

(1) RS485 Connection can be configured for AURORA Protocol or 

Modbus RTU.

Optional Remote Monitoring Logger

AURORA Logger Commercial (optional)

Ambient Operating Temperature Range

F(°C)

-22 to +140 (-30 to +60) , Derating above +113 (45)

Ambient Storage Temperature Range

F(°C)

-40 to +185 (-40 to +85)

Relative Humidity

%RH

0-100 condensing

Acoustic Noise Emission Level

dbA @1m

<50

<50

Maximum Operating Altitude without Derating

ft(m)

 6560 (2000)

 6560 (2000)

Enclosure rating

NEMA 4X

Conduit Connections

Bottom: (2) Concentric EKOs 1”,1½ ” , (2) ½” plugged openings, (1) 1” 

plugged opening

Optional PV String Combiner Fuse Size/Type

A/V mm

15/1000  10x38

15/1000  10x38

DC Switch Current Rating (Per Contact)

A

36

36

Optional AC Fused Disconnect Current Rating (Per Contact)

A

35

45

Isolation Level

Transformerless. Floating Array Required

Safety and EMC Standard

UL 1741, IEEE 1547, IEEE1547.1, CSA C22.2 107.1-01-2001, FCC Part 15 

Sub-part B Class B Limits

Safety Approval

cCSAus

All data is subject to change without notice.  

*Capability enabled within maximum input current, maximum input power, maximum output current, and ambient operating temperature limits.

**In -S1, -S1A and -S1B models, string polarity must be verified before connection.  Please refer to installation manual for correct installation procedure.

Содержание TRIO-20.0-27.6-TL-OUTD-US

Страница 1: ... guide the safety and installation information provided in the product manual must be read and followed The technical documentation for the product is available at the website The device must be used in the manner described in the manual If this is not the case the safety devices guaranteed by the inverter might be ineffective ...

Страница 2: ... has been factory programmed to automatically disconnect from the utility distribution system in compliance with UL 1741 and IEEE 1547 specifications Default voltage and frequency trip limit and trip time settings to comply with these standards are shown in table below The Service menu can be used to adjust Voltage and Frequency Trip Limit and Trip Time Parameters according to Grid requirements of...

Страница 3: ...rovide enough conductor to allow for movement of wiring box in final stages Hook wiring box on bracket by inserting heads of rear screws in bracket slots Remove wiring box front cover 08 Loosen connector screws 07 to remove coupling cover 04 and store in pocket at left rear of wiring box Locate four bolts protruding from rear of inverter chassis use as mounting studs and insert into four associate...

Страница 4: ...DC surge protection S1 S1A S1B versions 27 Equipment ground conductor EGC busbar 16 AC cable opening plastic threaded plug trade size 1 28 AC ground The DC EGC is common with the AC side and no other interconnecting jumpers are required If a 2 conduit is needed for DC cable DC cable entries can be punched to ccommodate using a knockout hole punch in location of existing knockouts 7 List of supplie...

Страница 5: ...ghten to chassis to maintain NEMA 4X compliance Connect raceway to chassis pulling conductors through raceway and DC cable openings 11 Connect to DC terminal block 13 Acceptable conductor cross section ranges from 12 AWG to 2AWG copper conductors only Tighten with at least 53 in lbs 6Nm torque Connect any Equipment Grounding conductors in raceway to EGC busbar 27 Connection of inputs on the S2F S2...

Страница 6: ...le inverter activate termination resistance of communication line by moving switch a08 or a09 to ON position Address on inverter is set through user interface on display panel area b7 section 13 Default address is set at 2 ATTENTION A A removeable transparent cover prevents access to the communication card in the wiring box remove four screws in place and remove cover to connect wiring Refer to te...

Страница 7: ...han Vstart icon b11 remains off Waiting Sun is shown in display area b7 and voltage and current are present icons b12 and b13 3 Assoonas WaitingSun conditionsaremet theinvertershowstheAFDboardself testrunning Theresultsareshownindisplayareab7 If a problem on the AFD board is detected the self test will result in an error Refer to section 16 below 4 If there are no irregularities the grid connectio...

Страница 8: ...l Grid Frequency Hz 60 60 Adjustable Grid Frequency Range Hz 57 63 57 63 Maximum Current Iac max phase ARMS 27 0 36 0 Power Factor 0 995 0 995 Total Harmonic Distortion At Rated Power 3 3 Grid Wiring Termination Type Spring Tension Clamp Terminal Copper wiring only 6AWG 4AWG type B or C stranding 19 strand max per conductor Fault Current ARMS 35 0 46 0 Reverse Polarity Protection Yes Passive inver...

Отзывы: