6.
Thoroughly clean the vacuum chamber of the squeegee body, first with a jet of water and then
with a damp cloth.
NB
: the place designated for this operation must comply with current environmental protection
regulations.
7.
Thoroughly clean the rear rubber blade of the squeegee body, first with a jet of water and then
with a damp cloth.
8.
Thoroughly clean the front rubber blade of the squeegee body, first with a jet of water and then
with a damp cloth.
9.
Thoroughly clean the vacuum nozzle with a jet of water, and then with a damp cloth.
10. Proceed in reverse order to reassemble all the parts.
To clean the debris hopper (with the optional spray gun kit), proceed as follows:
1. Take the machine to the maintenance area.
2. Using the DS selector on the control display (
Fig. 1
), select the “transfer” program” (1).
CAUTION
: these operations must be carried out using protective gloves to avoid any possible
contact with the edges or tips of metal objects.
3. Remove the vacuum tube (2) from the vacuum nozzle on the squeegee body (
Fig. 2
).
4. Completely unscrew the knobs (3) in the squeegee body pre-assembly (
Fig. 3
).
5. Remove the squeegee body from the slits in the squeegee connector (
Fig. 4
).
6. Release the tank cleaning accessory (4) (at the back of the machine) from the retainers (
Fig. 5
).
7.
Activate the optional tank cleaning kit ON/OFF pump by pressing the button (5) on the back of
the machine (
Fig. 6
).
CAUTION
: when using the optional tank cleaning kit, you are advised to always wear goggles
to avoid any risk of serious injury to your eyes.
NB
: before activating the optional tank cleaning kit, check the level indicator (6) to see how
much solution there is in the recovery tank (
Fig. 7
).
8.
Activate the solution jet by pressing the lever in the tank cleaning accessory. Make sure the jet is
pointing into the tank before pressing the lever.
NB
: to adjust the solution jet from the
tank cleaning accessory, turn the knob (7) on the
accessory itself
(
Fig. 8
).
N.B.
: to adjust the intensity of the solution jet from the
tank cleaning accessory, turn the knob
(8) on the accessory itself
(
Fig. 9
).
N.B.
: to stop the solution jet,
use the lever (9) on the tank cleaning accessory (
Fig. 10
).
9.
Thoroughly clean the vacuum chamber of the squeegee body, first with a jet of water and then
with a damp cloth.
NB
: the place designated for this operation must comply with current environmental protection
regulations.
10.
Thoroughly clean the rear rubber blade of the squeegee body, first with a jet of water and then
with a damp cloth.
11.
Thoroughly clean the front rubber blade of the squeegee body, first with a jet of water and then
with a damp cloth.
12.
Thoroughly clean the vacuum nozzle with a jet of water, and then with a damp cloth.
13. Proceed in reverse order to reassemble all the parts.
CLEANING THE BRUSH HEAD BRUSH (50BT VERSIONS)
Careful cleaning of the brush guarantees better cleaning of the floor, as well as a longer brush head
gearmotor lifespan. To clean the brush, proceed as follows:
1. Take the machine to the maintenance area.
2. Using the DS selector on the control display, select the “transfer” program”.
3. Press the brush uncoupling button (1) on the control display (
Fig. 1
).
4.
As soon as the button (1) is pressed, confirm brush uncoupling screen will appear (
Fig. 2
);
confirm the brush uncoupling by pressing the OK button (2) in the lower left-hand area of the
screen.
N.B.
: to close the confirm brush uncoupling screen, press the button (3) (
Fig. 2
).
5. Clean the brush under running water to remove any impurities from its bristles. Check the bristles
are not worn; in the event of excessive wear, replace the brush (the bristles should be at least
10mm long). When replacing the brush, read “
REPLACING THE BRUSH HEAD BRUSH
ATTENTION
: these operations must be carried out using protective gloves to avoid any
possible contact with the edges or tips of metal objects.
ATTENTION
: the place designated for this operation must comply with current environmental
protection regulations.
Careful cleaning of the brush guarantees better cleaning of the floor, as well as a longer brush head
gearmotor lifespan. To clean the brush (with the optional spray gun kit), proceed as follows:
1. Take the machine to the maintenance area.
2. Using the DS selector on the control display, select the “transfer” program”.
3. Press the brush uncoupling button (1) on the control display (
Fig. 1
).
4.
As soon as the button (1) is pressed, confirm brush uncoupling screen will appear (
Fig. 2
);
confirm the brush uncoupling by pressing the OK button (2) in the lower left-hand area of the
screen.
NB
: to close the confirm brush uncoupling screen, press the button (3) (
Fig. 2
).
CAUTION
: users are advised to always wear protective gloves, to avoid the risk of serious
injury to hands.
5. Release the tank cleaning accessory (4) (at the back of the machine) from the retainers (
Fig. 3
).
6.
Activate the optional tank cleaning kit ON/OFF pump by pressing the button (5) on the back of
the machine (
Fig. 4
).
CAUTION
: when using the optional tank cleaning kit, you are advised to always wear goggles
to avoid any risk of serious injury to your eyes.
NB
: before activating the optional tank cleaning kit, check the level indicator (6) to see how
much solution there is in the recovery tank (
Fig. 5
).
7.
Activate the solution jet by pressing the lever in the tank cleaning accessory. Make sure the jet is
pointing into the tank before pressing the lever.
NB
: to adjust the solution jet from the
tank cleaning accessory, turn the knob (7) on the
accessory itself
(
Fig. 6
).
NB
: to adjust the intensity of the solution jet from the
tank cleaning accessory, turn the knob (8)
on the accessory itself
(
Fig. 7
).
NB
: to stop the solution jet,
use the lever (9) on the tank cleaning accessory (
Fig. 8
).
24
3
2
2
3
Back
0000.00
100%
1
1
7
8
6
7
9
10
8
9
OFFICE
0000.00
100%
Main menu
Language
Hour meter
Zone programming
Parameters
Monitor
Alarms
Exit
Italiano
English
Spanish
French
German
Ok
1
2
1
2
3
OFFICE
0000.00
100%
Main menu
Language
Hour meter
Zone programming
Parameters
Monitor
Alarms
Exit
Italiano
English
Spanish
French
German
Ok
1
2
1
2
3
6
7
7
8
8
9
4
5
4
6
5
3
4
4
5
5
6
Содержание MAXIMA 2017 PLUS
Страница 2: ......
Страница 36: ...36 NOTE ...
Страница 37: ...37 NOTE ...
Страница 38: ...38 NOTE ...
Страница 39: ......